1.Introduction


JET pumps are with an automatic ejector system, widely used in domestic applications, gardens and supply water  



2. Construction


Pump Body: Cast Iron/Stainless Steel/Brass
Front Cover: Cast Iron/Cast Iron with brass insert / Aluminum


Impeller: Brass/Aluminum/PPO
Mechanical Seal: Carbon/Ceramic/Stainless Steel
Motor Housing: Alloy Aluminum

Shaft: Carbon Steel/Stainless Steel/High Frequency Wedding Shaft
Insulation: Class B / Class F
Protection: IP44 / IP54
Cooling: External Ventilation


With thermal overload protector in single phase motor


 




3. Operation Conditions


Suction head up to 9M


Liquid temperature up to 60C
Ambient temperature up to 40C
Max.Pressure:9Bar




Q: Working principle and diagram of axial piston pump with pressure compensation variable
Working principleThe main part (see section structure) the transmission shaft drives the rotating cylinder, the plunger seven uniform distribution on the cylinder to rotate around the shaft center line through the center of the spring will be slippery boots column components in the variable pressure in the head (or swash plate). In this way, with the rotation of the plunger cylinder for reciprocating motion complete, oil absorption and oil pressure action.
Q: How does the centrifugal pump pump and cut the pump?
Turn on the motor, observe the motor current, turn from high to low, observe the pump outlet pressure, and the pressure rise;Slowly open the outlet valve, so that the pressure drop slowly, the current slowly rising to the stable, the outlet valve to the maximum;Check the pump operation, stuffing box leakage, current, whether or not the rated current, motor, bearing temperature is normal, whether or not abnormal sound.
Q: Is the diaphragm pump and the drain pump one?
Therefore, the need to play a liquid discharge pump, if the medium is corrosive liquid, high viscosity, volatile, flammable, highly toxic liquid, you can choose diaphragm pump. Conversely, the general liquid, there is no special requirements, you can use the general centrifugal pump to reduce costs.
Q: Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
SK vacuum pump is a single-stage water ring vacuum pump, vacuum pump and motor separation, coupled with couplings, vacuum relatively low.
Q: Working principle and structure of external gear pump
When the meshing teeth on one side of the suction chamber are gradually separated, the volume of the suction chamber is increased, and the pressure is lowered, and the liquid in the suction pipe is sucked into the pump; the suction liquid is divided into two parts to be pushed into the discharge chamber by the gear in the alveolus. When the liquid enters the exhaust chamber, the liquid is squeezed and discharged from the exhaust chamber into the discharge pipe because the teeth of the two gears are continuously engaged. The driving gear and the driven gear keep rotating, and the pump can continuously inhale and discharge the liquid. The pump body is equipped with a safety valve, when the discharge pressure exceeds the required pressure, the delivery liquid can automatically open the safety valve, so that the high-pressure liquid returns to the suction pipe.
Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
Submersible pump cable or motor insulation is damaged.3) motor water solution
Q: Significance of water pump model ISO50-160
A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance parameters include flow, suction, lift, shaft power, water power, efficiency and so on;