• JET Self-priming Electric Water Pump for Irrigation System 1
JET Self-priming Electric Water Pump for Irrigation

JET Self-priming Electric Water Pump for Irrigation

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Specifications

1.For domestic and high efficient
2.small size and low-noise
3.Cast-iron casing,brass impeller

 

JET Self-priming  electric water pump

 

PUMP INSTALLATION AND APPLICATIONS


JET Series Self-priming clear water pumps combine the functions and advantages of centrifugal pumps and self-priming pumps.Being majorizing, taking short time in self-priming, reliable, compact, with high discharge head, high suction head and high efficiency etc. They are suitable to carry clean water with temperature less than 45¡æ. They can be widely used in industrial and mining enterprises, water supply for high buildings, agricultural irrigation and water treatment etc.

 

Working Condition


Suction lift up to 9 m 
Liquid temperature up to +40o
Ambient temperature up to +40 o
Max. Working pressure: 6 bar

 

PERFORMANCE RANGE

 

Flow rate up to 60l/min(3.6m3/h)

Head up to 45m 

 

Structure feature


Pump body: Cast iron
Impeller: Brass
Motor Housing: Aluminium
Front cover: Cast iron
Mechanical seal: Ceramic - Graphite

Shaft: 45#steel or stainless iron
Bearing: SKF/NTN/NSK/China
Insulation class: B and F
Protection class: IP44 and IP54

 

 

modelpowerQ.maxSuct.maxspeedPipe Dia.package diamensions &GW
HPKWL/Minmr.p.minchWLHKG
JET-60L0.60.4540928501"*1"44020523715
JET-80L0.750.55501"*1"47520023017
JET-100L10.75601"*1"44020523718
JET100L-110.75601"*1"44020523718

 

Q: How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: Is the vacuum pump air compressor?
No, both work in the opposite way. Air compressor, referred to as an air compressor, is a machine that produces compressed air (positive pressure). The vacuum pump is just the opposite.
Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
The ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and rotor drive. The structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so the utility model can be completely free from leakage.
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
Installation method of hydraulic pump(1) according to the technological requirements and the cavitation conditions of the pump, the installation height check and the civil engineering of the foundation are carried out.(2) prepare a series of flat washers and wedge gaskets of different thickness before installation.(3) according to the characteristics of the pump conveying medium, determine the material of the gasket at the connection and process the gasket.
Q: What are the conditions required for hydraulic pumps to complete oil absorption and compression?
Volume conditions: oil absorption cavity from small to large, complete oil absorption, oil pressure chamber has become smaller, complete pressure oil.Sealing conditions: the hydraulic pump itself should have good sealing
Q: What is a feed pump?
In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
When the valve is closed, the flow of the pump is close to zero, the power of the pump is very small, which reduces the load that the motor starts to bear and has a protective effect on the motor. Therefore, the valve closed to start the pump.
Q: How accurate is the metering pump?
The measuring accuracy of the stable metering pump is as follows:In a diaphragm metering pump, the reciprocating motion of the plunger is passed to the diaphragm through the hydraulic chamber between the plunger and the diaphragm. In order to maintain the normal movement of the diaphragm, the hydraulic chamber is required to keep the volume of the liquid in the space (usually using hydraulic oil) unchanged. In order to ensure that the volume of the formation of membrane movement is always equal to the stroke volume of the plunger pump, so as to maintain the stability of the flow, but in the actual operation of the pump, the plunger seal will inevitably cause leakage at the same time, there may be a gas into the hydraulic chamber
Q: What do you mean by the self coupling device on the pump?
Installation of GAK self coupling device:The installation of automatic coupling submersible sewage pump is mainly the installation of coupling device and the lifting of pump. In the pump before the installation of the rings on the chain, and the pump used for lifting.Installation procedure of coupling device:The coupling frame with four bolts fixed on the pump body; the water outlet pipe is fixed on the substrate; positioning cone mounted on the pipe seat; the lower end of the guide pipe is sleeved in the positioning cone, the upper end is sheathed on the guide rod of the rubber block; the guide rod frame is fixed on the pool wall. The function of the rubber block: the axial compression degree of the rubber block is adjusted by the screw on the guide rod frame, so that the diameter of the rubber block is consistent with the inner diameter of the guide rod, and the guide rod is stable.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords