JET Centrifugal Water Pumps With High Quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 12000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Introduction JET pumps are with an automatic ejector system, widely used in domestic applications, gardens and supply water 2. Construction Pump Body: Cast Iron/Stainless Steel/Brass Front Cover: Cast Iron/Cast Iron with brass insert / Aluminum Impeller: Brass/Aluminum/PPO Mechanical Seal: Carbon/Ceramic/Stainless Steel Motor Housing: Alloy Aluminum With Thermal Overload protector in single phase motor. 3. Operation Conditions Suction head up to 9M Liquid temperature up to 60C 4. FAQ 1) Are CNBM pumps available in DIY stores? Yes, currently, we’re available for DIY stores all over the world. 2) Where do I have to send pumps for service? You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China. 3) Are your pumps acid-proofed? To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid. |
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q: Water pump can not be pumped out, how to maintain water?
- The pipe leaks or leaks:The nut may not pinch well when it is installed. If the leakage is not serious, it can be coated with cement or mixed with asphalt oil in the places where the gas leaks or leaks. Temporary repairs can be done with wet mud or soft soap. If the leakage at the joint, you can tighten the nut by hand. The leak is critical and must be re assembled.
- Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
- The graphite bearing lubrication medium, make the operation less noise and manual, reduce maintenance costs; in recent years, bearing material added with silicon carbide SIC, super hard, life is better than that of graphite bearing.The vertical structure can be installed on the pipeline like a valve, the installation is convenient and quick, and the motor and the impeller can be drawn out only when the utility model is used, and the pipeline is not needed to be removed.The utility model can be installed and run with a shock absorber or a damping pad, so that the pump is less noisy at running time.
- Q: What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
- Displacement of a pump: the volume of the discharged liquid calculated by the change in the size of the sealing geometry for each revolution of the hydraulic pump
- Q: How high can the pneumatic diaphragm pump be?
- Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
- Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
- Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.
- Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
- The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
- Q: How to maintain and repair the booster pump of pipeline pump?
- 4. install "0" ring, tighten the pump body and motor end cover with bolts. Notice that the clearance between the front cover of the impeller and the pump body is 20. 0.5 mm. The impeller inlet, the outer ring and the pump body ensure a certain running clearance.5. the disassembly order is the opposite.
Send your message to us
JET Centrifugal Water Pumps With High Quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 12000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords