IS single-stage end-suction centrifugal pump with high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
IS single-stage end-suction centrifugal pumps Details:
Minimum Order Quantity: | 1 set | Unit: | set | Loading Port: | Shanghai |
Supply Ability: | 4000 set/month | Payment Terms: | TT OR LC | Package: | Carton Box |
Product Description:
Product Description:
<1>Outline :
IS series single-stage end-suction (axial intake) centrifugal pump is an energy-saving pump designed by teamwork in the whole nation, it is improved on a basis on model BA, B and other single-stage water centrifugal pump. The advantages: its hydraulic capability is distributed reasonably, wide option for user, conveniently check and repair, the efficiency and throw is up to advanced international level. This pump is suitable for industrial and city water supply, water drainage, and widely used for agricultural irrigation, transportation pure water or other liquids whihc physical and chemical nature is similar to pure water, and the temperature should not be higher than 80 .
<2>Features:
1)Speed: 2900RPM and 1450RPM;
2)Suction: 50~200mm;
3)Flow/Capacity: 6.3~400m3/h;
4)Head: 5~125m.
<3>Application:
a)Municipal water supply and drainage
b)Water circulation of air conditioner
c)Agriculture hydraulic engineering,such as irrigation,drain flooded fields etc.
d)Industrial water supply system,fire fighting system,drainage of heating system.
e)Transport of clean water or liquid of which physical chemical properties similar as water
<4>Construction
1. IS series single-stage end-suction centrifugal pump is designed ac cording to the capability and size stipul ated i n the internati onal Standard ISO2858, it is composed of pump body,pump cover, impeller, shaft, ring seal, sleeve and suspended bearing units.
2. The pump body and pump cover in IS series are separated from the back of impeller, that is to say in general, back open structure, whose advantages: convenient overhau l,when checking and repairing, the pump body intake pimp,discharge pipe and motor need not to move, just disassemly the middle connector of extended coupling to quit therotor units for overhaul.
3. The pump shell (that is pump body and pump cover)forms the workroom of pump. Impeller, shaft and rolling bearing are the rotors for the pump. Suspended bearing units support the rotors in the pump. The rolling bearing stands the radial load and axial force.
4. In order to balance the axial force of the pump, most of the pumps are designed with sealing rings at the front and back of impellers and a balance hole on the rear impeller cap plate. The reverse of impeller is not designed with sealing rings or balance holes if pump axial force is not powerful.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 3, larger than 25000, the minimum water consumption of indoor fire hydrant is 20L/s4, the minimum water consumption is the flow of a fire hydrant.
- Q: What are the internal losses in centrifugal pumps? How did they come about?
- Volume loss: loss due to leakage;3. mechanical loss
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- Pump downstream equipment design pressure is greater than 3MPa, if it is 400 meters, the downstream equipment design pressure is greater than 4MPa
- Q: Concrete pump 125 pipe wall thickness
- Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
- Q: What is the function of the heating pump system for the water pump design?
- As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.
- Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 1., consciously abide by the traffic control department management rules, to achieve civilized driving, safe driving.2. responsible for the daily maintenance, cleaning and cleaning of the pump truck, and ensure the equipment is in good condition.
- Q: Is the flow meter in front of the pump or after the pump?
- After the pump, the reasons are as follows, before the pump, you pump fluid through the pump will produce negative pressure in front of the pump, negative pressure on the flow of the life of the impact, the pump will not, Suzhou first Chi meter
- Q: How many concrete pump tube diameter
- The pump is generally divided into 125 and 150 two, the inner diameter is 125mm and 150mm. And the two kinds of each have high and low pressure points. Low pressure type type 125 pump for the pipeline diameter is phi 133,
- Q: What does "dual purpose" of water pump mean? Please expert advice
- 1, if the water pump in the process of a strong vibration, then must stop to check what is the cause, otherwise it will cause damage to the water pump.3, when the pump valve Water Leakage, some people will fill with dry soil to the water pump inlet pipe, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started to work, these dry soil will enter the pump, then it will damage the pump impeller and bearings, thus shortening the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that need to replace the new.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.
Send your message to us
IS single-stage end-suction centrifugal pump with high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords