Insulfoam Roofing Insulation - Single Bubble Foil
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 40HQ m²
- Supply Capability:
- 20 Tons Per Week m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications of Single Bubble Foil
STRUCTURE |
ALUMINUM FOIL/BUBBLE/ALUMINUM FOIL |
THICKNESS |
3.5-4mm |
DENSITY |
85kg/m^3 |
WEIGHT |
275g/m^2 |
BUBBLE SIZE |
4mm HIGH x 10mm DIAMETER |
WIDTH |
1.2m (MAX 1.5m) |
THERMAL CONDUCTIVITY |
0.034w/mo |
REFLECTIVITY |
96-97% |
Usage/Applications of Single Bubble Foil
This product is laminated by the aluminum foil and bubble. It is the better product in the environmental protection, thermal insulation thermal insulation. The outermost PET has good abrasion resistance and high strength tear resistance. The bubble between the aluminum foil not only has a strong moisture, resistance oxygen, sound insulation, drop noise function, but it is also has very good reflective inverse heat, blocking ultraviolet.
Packaging & Delivery of Single Bubble Foil
Each roll is packed by plastic film
- Q: were can i buy material to insulate pans and instructions to install it? I have seen many roofs with this done ,but , the lowe,s and home depots don't have .
- I think your problem is in the way you are asking the question. I for one do not know what you mean by a metal pan roof. I know all about steel roofs or corrugated roofs and a lot of other roofs but what is a metal pan?
- Q: what action should a plumber take?????
- struggling to understand your question! are you talking about a storage tank? what is the problem with the insulation? if it is in the way move it but insulation under a tank is not a problem the tank will need to be insulated any way!
- Q: So I'm renovating an old farmhouse with a metal roof and there is no insulation in the attic. I was up in the attic checking for leaks since we just got some freezing rain and it is currently melting I thought now was the perfect time to check. I found no leaks but I did notice the roof was sweating with noticeable beads of water in many places and many of the 2x4's that act as the frame were damp, although none were rotted (I found that odd as the house is approx. 140 years old and those are the original 2x4's. I could tell that the attic does have vents so I guess it dries out before rotting or mold occurs.. but makes me wonder if I put down some roll-in faced R-30 Owens Corning Insulation and then add a plywood floor over top if everything will be fine.. or not so fine..
- Hi, GA. On my second coffee here, so bear with me if a little fuzzy. Trying to envision what you're looking at, first thing I hear is 2x4 roof framing, not say the 2x6 or 2x8 rafters I would expect. A 2x4 structure and metal roof is a light build more suitable for a shed or outbuilding than a home. Wouldn't tolerate much additional weight, like from plywood. Next thing, which I don't hear, is whether there's moisture on the attic's "floor", where you're standing. I'm thinking the moisture you're noting is above you, on the undersurface of the roofing, and on the rafters. Finally, while some condensation on the underside makes sense, it would also seem quite possible that there are a number of small leaks through the roof. My goals would be to first ensure there are no leaks through the roof surface, then to ensure the attic indeed has enough venting, then to both reduce air from the lower living level bleeding through up to the attic space (also good to reduce convective heat loss), then to insulate the attic floor to reduce radiant heat loss from below and warming of the attic air, pretty much in that order. The prize is a leak-free roof over a cold attic space.
- Q: i live in a tropical country and i need to insulate my roof to block off the heat from the sun...which insulation would best help me? aluminum foil with foam, real foil with foam or PE with foam? pls help...thank u so much!
- Expanded polystyrene (EPS) comes in sheets and is very long lasting and safe to use - no fibers, no itchy skin, no breathing issues....this is also used to keep cold out as well as heat and is durable.
- Q: is it safe to put insulation in the corners where the roof meets the wall in attics?fiberglass in corners?
- If you have vented soffits, you have to stay away from the corners where the outside wall meets the roof. It is best to install insulation baffles to the roof sheathing to keep the fiberglass from stopping the natural ventilation through the soffit vents into the attic. They can be purchased at home improvement store.
- Q: I know when you inhale the insulation from the roof irritates the throat but what can you do to clear it from your throat after inhaling it?
- it's not your throat you should be worried about. it's your lungs. wear a respirator....or at the very least, a dust mask. you only live once so make it last.
- Q: I am purchasing a mobile home with a shingled roof. The shingles need to be replaced (>15yrs old) and with the cost of heating going up each day I thought I would added some of that 2" thick rigid insulation. I would place this right on top of the existing roof and then place the firring strips for the metal roof right on top of the rigid insulation panels (which are 4x8'). By using 3" galvanized sheet rock screws I will get a good solid attachment. Then I will put the metal roofing on to the firring strips as normal. Does anyone see any downside to doing this? Has anyone tried this before?
- I agree with the soundness of every part of your plan EXCEPT not removing the original shingle roof. The shingle roof is already at the end of its usable life. There’s no benefit to covering up old problems, and they will most likely affect the durability of the new roof. Plus, removing the old roof gives you the opportunity to inspect and repair any issues with the roofing deck. Your new insulation and metal roof will attach better and perform better by removing the old shingle roof.
- Q: I added a screened room to my mobile home. I also have vinyl windows. in the summer the sun beats down on the home almost all day Someone told me I could have insulation installed in the roof panels, and that i may even be able to do it myself. Right now it's impossible to enjoy my patio between 1-5pm because it so hot you can't breath. I'm in the Pasco, FL area - 34667Appreciate any help you can give
- I agree with RustyNail that the panels are thin and not meant to support that kind of weight. But, I think a wall anchor that spreads the weight inside the foam would work if that's the only place to attach. I'm imagining that there's no wall available since these usually are just supported at the ends. If so, then my first suggestion would be no curtains at all. My second would be to find a long wall anchor. With 6" of foam, I would think you could do a 4" long anchor and get pretty good support. Rusty may disagree.
- Q: I am thinking about getting cavity wall and roof insulation at the moment.But since summer is approaching, I fear that getting the insulation will mean that the house will be very hot at night. (During day time the house will accumulate heat from the sun, and the heat cannot escape).I also fear that the ventilation will be bad and the air in the house will not be as fresh.Any advice please?
- Insulation works to keep a home cooler in summer as well as warmer in winter. And the warm months generally mean better conditions for the installation because of less potential moisture, which sometimes forms in uninsulated homes in the freezing cold, being trapped in ceiling and wall cavities. To have your ceiling insulation function properly, attic ventilation is required. This is approx. 1 sq. ft./ clear ventilation to 300 sq. ft. of attic space. More is better than less. You will find your home cooler. Insulation on its own does not change ventilation. This is an air/vapor barrier situation which also should be considered when insulating.
- Q: I am in the process of having a new roof installed. What are my options in regards to improving its' insulating properties?
- If you have clear access to your rafters, the best insulation possible (after installing your vent baffles) is sprayed on foam. I didn't say polyurethane foam on purpose, as there is now a soy based foam available with exactly the same working and thermal characteristics as the petro-poly goop, with none of crude oil. But i digress. Sprayed on foam has the advantage of not only thermal insulation but it also seals everything that it comes in contact with, thus stopping any air movement, something that no fiberglass or extruded polyurethane could ever do. Industry experts are still debating this but, it looks like 1 inch of sprayed on foam (with it sealing qualities) does as much, if not more, than 3 1/2 inches of fiberglass and, foam will never sag or absorb moisture like glass does. Fill your rafter spaces and gloat to the neighbors when your bills come in. :)
1. Manufacturer Overview
Location | Zhejiang, China |
Year Established | 2004 |
Annual Output Value | Above US$ 0.2 billion |
Main Markets | 20.00% Mid East 15.00% Northern Europe 15.00% North America 12.00% Eastern Asia 10.00% Africa 9.00% Eastern Europe 8.00% Southeast Asia 4.00% Oceania 3.00% Western Europe 2.00% Southern Europe Mid East;South east asia;North America |
Company Certifications | ISO 9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 20 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 100,000 square meters |
No. of Production Lines | Above 4 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | Average |
Send your message to us
Insulfoam Roofing Insulation - Single Bubble Foil
- Loading Port:
- China Main Port
- Payment Terms:
- TT or L/C
- Min Order Qty:
- 40HQ m²
- Supply Capability:
- 20 Tons Per Week m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords