Hot Dipped Galvanised Steel Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Hot Dip Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: 14. Three parallel wires carry currents, with magnitudes and in the directions shown in the figure below. The wires all lie in a plane, and are all 2 m long, with separations between them as shown in the figure. What is the total force on wire #3 due to wire #1 and wire #2? Wire 1 : 6A, 2.5 m from Wire 3 ---------------------gt;Wire 2: 3A, 1.0 m from Wire 3 lt;--------------------Wire 3: 3A ---------------------gt;Can't figure it out, any hints/suggestions?
- The formula for force between wires is: (?/2π)(current1)(current2)(length/r) ? = 4πE-7 Tm/A r=distance between wires For this problem, you would just find the force on wire 3 of each one separately. Since wire 2 is going opposite direction as wire 3, they repel each other, while wire 1 and wire 3 attract each other since they are going same direction. I get Fwire1 to be 2.88E-6 N, and Fwire2 to be 3.6E-6N. Then subtract them since opposite forces, and since Fwire2 is stronger, the force would be 7.2E-7 N away/repelling.
- Q: i have my wires installed by a professional, and i wanted to put an taco switch to run to my amp, if i run a taco switch will it be okay? and with messing up the wires that he already ran would it screw it up?
- Are you wanting to listen to your stereo with your Sub off sometimes? There would be no problem putting a in-line toggle switch on your REM wire. Just look at the color of the small wire going into your amp, then find that wire under the dash. Cut the wire and strip both ends. Connect one side of the toggle to one wire and the other side to the toggle to the other wire . Now it is just a In-line switch. mount it where you want Turning this off and on wont hurt your amp.
- Q: i want technical names of the electrical equipments rheostat,wire wound
- rheostat: rheostat wire: wire wound: ? wound noun 1 a chest wound injury, lesion, cut, gash, laceration, tear, slash; graze, scratch, abrasion; bruise, contusion; Medicine trauma. .
- Q: i changed the sprak plugs wires on my 1990 300e and when i put the car on Drive it vibrates strongly. i kept checking that each wire is in the right place and on. do i need to restart the brain or reprogram the car ?
- Sounds like you still have a wire crossed somewhere. Just for the future Change one wire at a time. Hope this helps good luck!
- Q: where can i buy these type of wires (copper insulated wires)??
- Any hardware store or Lowes, Home depot There's nothing special about Insulated wire, but what size wire ? What's your application ?
- Q: THERMOSTAT WIRING
- try this site
- Q: home, thermostat, wiring
- green wire is 24 volts from the t-stat to the indoor fan relay, i promise! unless it's a trane. trane has their own wiring codes and i don't remember trane wiring at this time. i can look it up but don't want to. green goes to the indoor fan relay, for real. the fan relay energizes 110 volts and turns the indoor fan on. be careful jacking around with that stuff. remember, you have low voltage from the transformer and t-stat and high voltage everywhere else. the outside stuff is 220 volts. ZZZZZZZZZZZZ!
- Q: Im wondering if this 24 awg wire is good for guitar wiring. Doesn't look like something that i usually would see people use when wiring, since there is lots of different wires and colour coding wrapped up inside it.
- Given okorder / I hope this will help with your decision. Good luck!
- Q: currently I have 2 12woofers wired to a single amp with 2 gauge wiring. Will it make a noticable difference if I upgrade the wiring to 0 gauge?
- No. Even if the wire is undersized there would have had to have been a LOT of voltage drop in the 2 awg compared to the 1/0 awg wire, AND the amp would have to be loosely regulated for there to be any significant improvement. If both of those things are true it's still not likely there'd be enough of a change to be audible.
- Q: A 5.07 m length of 2.1 mm diameter wire carries 703 mA current when 22.3 mV is applied to its ends. Determine the resistivity of the wire.
- Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m Use current and voltage to determine resistance. Plug that into the above and solve for ρ. Be sure to change numbers into meters.