Specifications
1.Higher torque in low speed
2.More smooth & stable running no resonance
3.Low temperature rise, higher effeciency
BPT series frequency conversion speed regulator is your best choice for flux control air fan, water pump and compressor. This product can meet all kinds of demands, operation modes and complete protection functions.
Features:
1 Advanced space voltage vector control technology, much better than traditional wave control technology:
1.1 Higher torque in low speed;
1.2 More smooth & stable running, without resonance;
1.3 Low temperature rise, higher effeciency.
2. Perfect protection system design
Special short protection technology can assure release when short and earth(ground) fault happened.
3. Long longevity
The max. Temperature rise is 20º C that can prolong the service life.
Working condition
Upper limit of ambient temperature is no more than +50º C;
The relative humidity is no more than 85 percent. The height above sea level is no more than 2000m;
It should be placed on an indoor place without obvious shake and impact, without fire and explosive dangers and the vertical gradient is no more than 5º ;
There must be no conductive dust and corrosive gas.
Specification
Model | A03/050~ | A03/100~ | A03/175 ~A03/220 | A03/220~A03/400 | A03/220~A03/610 |
Capacity(kVA) | 250~630 | 630~900 | 900~1150 | 1150~2000 | 2000~3125 |
Rated output current (A) | 50~100 | 100~175 | 175~220 | 220~400 | 400~610 |
Motor power (kW) | 200~400 | 400~710 | 710~900 | 900~1600 | 1600~2500 |
Input frequency | 45Hz~55Hz | ||||
Rted input voltage | 3000V±10% | ||||
Input power factor | 0.95 (>20%load) | ||||
Efficiency | 0.96 with rated load | ||||
Output frequency | 0.5Hz~120Hz | ||||
Frequency resolution | 0.01Hz | ||||
Overload capacity | 120% 1 min, 150% immediately | ||||
Analogue input | 0~10V/4~20mA | ||||
Analogue output | 0~10V/4~20mA | ||||
Acceleration/deceleration time | 0.1~3000s | ||||
Digital output/input | expanded according to requirement | ||||
Ambience temperature | 0~40°C | ||||
Storage/transport temperature | -40~70°C | ||||
Cooling | air cooling | ||||
Ambience humidity | <90% without condensation | ||||
Altitude | <1000 m | ||||
IP class | IP20 | ||||
Size(mm)(W×H×D) | 3300×2480×1200 | 4900×2480×1200 | 6000×2580×1300 | ||
Weight (kg) | 3000 ~5000 | 5000 ~7300 | 7300~9200 |
- Q: How to view the parameters of the notebook power adapter on your computer
- Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled. Notebook power adapter using the correct method] 1. Try to avoid the use of outdoor or harsh environments to prevent the adapter is exposed or damp. 2. When you are not using the adapter, please unplug the power plug. Because, for a long time the power will let the adapter has been in working condition, will affect the end of life. 3. Although the adapter is a broadband operating voltage, marked from 100V-240V can be, but if the voltage is extremely unstable in the case of use, the same will cause damage to the power adapter.
- Q: My Lenovo v450 laptop power adapter should be bad how to match?
- Hello, this is not recommended to go online to buy. The original is too expensive, generally with the domestic voltage instability may occur, so I suggest you go to the computer city to buy. Generally good quality, to about 120. The The As for the model, you can look at the output power, or you take your bad adapter to go, people see a look. The The The You can use a few years no problem, power adapter this kind of thing, online to buy the replacement is not convenient. The Hope to help you
- Q: What is the common COM point of the PLC and the inverter? Is it positive?
- Plc is divided into two kinds of transistor output and relay output, com side may be connected to the high level may also be connected to the low level, the general input com port then low, the output port com mouth high, specifically what to take See the data sheet. Inverter is the same, the inverter has 24v com side and 10v com side, can not be connected together, com side generally low.
- Q: Can the laptop power adapter be generic?
- Not common. Different computer adapter interface is not the same, and the voltage, current is not the same. If just the same, you can use, the voltage can also be used.
- Q: Asus notebook power adapter how to open
- if the power adapter is broken directly to the computer with a city on the line can not spend a few money back you can burn the computer is bigger to go to the computer The city took to repair and no one to repair to buy a very low price
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- First, the inverter is no problem, I used so much to meet your needs ????? But to see if your motor can run at high speed, or whether the load is small, the power to have a general amount of redundancy. 6-pole motor synchronous speed of 1000, to meet your use to be transferred between 2000 or 1900, that is to say the frequency converter output frequency to be transferred to 90 to 100HZ. ????? Constant torque load is no problem, but the fan torque load to be a small job.
- Q: Is the motor having a variable frequency motor and a variable voltage motor?
- Motor with DC and AC motor, variable frequency motor and fixed frequency motor, string motor, that is, I have not heard of a transformer motor.
- Q: 22kw.2 pole fan can use Fuji inverter?
- Definitely yes. 2-pole motor and four-pole motor difference is: the current is different, the speed is different, the torque is not the same,
- Q: What is the output voltage of the laptop power adapter?
- Laptop power adapter output voltage, different brands may be different. Adapter output voltage is not a unified standard, different models are not the same notebook. The output voltage between 12V to 20V, 19V, 20V more.
- Q: Jd1a-40 motor speed controller and how to connect the motor
- Speed ??control motor wiring method: 3.4.5 is the terminal of the tachogenerator (U / V / W) from the right-to-left order of 1.2 for the excitation coil (F1 / F2) terminal, from the extended end of the speed motor (electromagnetic clutch) Master 7 plugs on the air plugs (governor): terminal 1.2 for the 220v input, 3.4 on the speed of the motor on the excitation coil, 5.6.7 speed motor on the tachogenerator. Motor speed control method: The speed regulating motor is to change the speed of the motor by using the series, voltage, current, frequency and so on of the motor to make the thyristor voltage regulation method the best.
Send your message to us
High Voltage Frequency Drive 10KV 500KW VFD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords