• High quality Multicore Soft Wire with a good price System 1
  • High quality Multicore Soft Wire with a good price System 2
High quality Multicore Soft Wire with a good price

High quality Multicore Soft Wire with a good price

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
10000 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Multicore Soft Wire


High quality Multicore Soft Wire with a good price

Multicore soft wire for connecting have a few core. It is commonly used as control circuits and signal circuits in power plant and switchgear installation of transformer substation.


Performance


1. Products based on GB5023 and JB8734 national standards.

2.The wire was immersed for one hour and subjected to AC 50Hz250V (450 / 750V), 2000V (300 / 500V)

voltage test for 5 minutes without breakdown.


Characteristic


1. This product is suitable for AC and DC rated voltage 450 / 750V and below power, household appliances, instruments and telecommunications equipment and other lines.

2. Long-term working temperature of wire should not exceed 70 ℃, BV-90 Model should not exceed 90 ℃.

3. Wire laying temperature should not be less than 0 ℃; allow bending radius; wire diameter (D) is less than 25mm are not less than 4D; Wire diameter (D) of 25 mm and above shall be not less than 6 (D).


Introduction of our company


Our company  is a professional China Wire and Cable Manufacturers, mainly supply Aerial bundled cable,House Electric Wire, Insulated Overhead Cable,Aluminium Conductor Steel Reinforced, PVC Control Cables,XLPE Power Cables,BV Electric Wires,Nylon Sheathed Cable,Buried Cable,High Voltage Cable,House Electric Wire,Single Core Flexible Copper Cable,Civil Wire And Cable etc. series of wire and cable products, sincerely welcome everyone to visit.



Q: I have tried hot sauce. I have to cover all my wires with car wire covers.
The only way is to hide the wires
Q: Do these wires provide warmth for the birds?
Because they always look for a higher place to perch, and these wires provide no heat, they are of no interest to birds rather than being high
Q: I noticed when somebody uses the microwave my tv starts to make REALLY loud zap noises and a staticy bar rolls down the screen. The tv does it on its own sometimes and I thought I saw the hallway lights flicker a bit when it happened.If I flip on the bedroom light the tv does the same thing again or if I unplug something from an outlet on the other side of the room. I don't know why EXACTLY, I only know its wiring if you can explain further please do. Also, if an electrical fire happens what should I do? Obviously no water because duh but do I cover it in baking soda? I saw that a lot on different websites. I do not own the correct fire extinguisher so what else would I use? Thanks for any answers!
Possibly get rid of microwave, because of suppressor failure. It has been suggested for a good 30-40 odd years that sockets in the kitchen are on an independent breaker from the other socket outlets on the premesis. It probably only in the last decade/ 15 years that the socket outlets have actually been wired like this.
Q: i need another outlet in my room and i am thinking of running a heavy duty electrical wire (about 25 ft long) through my window an into my bedroom. my question is. is if it is safe to leave the wire running around the back of my house when it rains? does anyone know whether the outdoor wires you usually use for electrical edgers, blowers, etc. can withstand the rain while it is being used?
normal electrical extension leads are useable but its not legal by auustralian laws for permanent wiring in a house hold to be flex and the std minimum size is 2.5mm ext leads are nomaly from0.75 to 2.5 ave 1.5mm and would cause you insurance problems if you had a fire if its all one piece with out damage to the outer or inner insulation your ok for rain, sun light will make it go brittel and may well lead to cracking then it will short out or electricute you or someone lese which is not a good thing
Q: If the fuse for the headlights is in, the lights stay on and the wires start burning! (Piece of crap NEON)
Sorry to say this, but to your local dodge dealership.
Q: I am installing a new light switch on the inside of an exterior wall in my walkout basement. Because of the floor joists and finished ceiling, the only way I can figure to get the wiring to that location is by punching it through to the outside and running it along the wall and over to the location of the switch. This run will be about 30ft long and go around one corner. My question is: Can I do this with bare UF (outdoor romex) wire? Or will the wire need to be installed in a conduit?
Wires above ground should be in a conduit to protect them from abrasion. Grey romex is okay for underground without a conduit, as long as it's buried at least 18 in the soil.
Q: Going by the chart of wire sizes and how many amps different sizes can handle, here's my question. I see a # 10 guage wire can hold 30-35amps. However, can it hold more amps if it were being used for the neutral?
No, and the wire size must always be sized larger than the circuit breaker.
Q: What is the maximum current through the eight square copper wires
Cable bridge installation specifications inside: cable bridge multi-layer installation control cable between not less than 0.2M, power cable between not less than 0.3M, weak cable and power cable between not less than 0.5M, if the shield cover can be reduced to 0.3M, The upper part of the bridge is not less than 0.3M from the ceiling or other obstacles. Different voltage for different purposes of the cable should not be laid in the same layer of the bridge if the conditions are limited to laying in the same layer of the bridge, the middle need to add partitions. In order to prevent the human body from touching or excessively close to the charged body, or to prevent the vehicle and other objects from colliding with the charged body, and to avoid a variety of short circuits, fires and explosions, between the body and the charged body, between the charged body and the ground, Between the charged body, between the charged body and other objects and facilities, must maintain a certain distance.
Q: Seeking similar to the heifers Tim wire B with lightning. Similar words.
The general use of concrete encapsulation, is the need to have cable protection tube, can not be buried cable cable protection tube with hot-dip steel pipe, glass pipe, MPP power pipe these several commonly used
Q: I have a 15A 120V circuit that has a ceiling light controlled by an end-of-run-switch. At the switch box there is the ground wire, black wire and the white wire which is colored black.I would like to install an outlet between the ceiling light and the switch that would also be controlled by the switch. Can this be done, and if so, what would the wiring arrangements be?I have good access to where I want to install the outlet and could change or replace the wire between the outlet and the switch. Changing any of the rest of the wiring would be a real project though.(As to my own abilities here, I've done a lot of straight-forward barn type wiring on my farm (outlets, 3- and 4-way switches, etc.) and understand what the black-colored white wire means in this situation. But I wouldn't presume to wire a house.)Thanks!
from the fan box in the ceiling run a romex cable to the outlet so you have a hot, neutral and ground. the black wire coming from the fan box and going to the outlet should be tapped from the hot wire being controlled by/downstream of the switch and powering the fan, not the hot wire powering/going to the switch. make sure your switch is rated for the amount of amps needed.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches