• High Quality Hot Dipped Galvanized  Wire System 1
High Quality Hot Dipped Galvanized  Wire

High Quality Hot Dipped Galvanized Wire

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Packaging & Delivery

Packaging Detail:1. Inside with plastic film, outside weaving bag. 2. Inside with plastic film, outside hessian cloth.
Delivery Detail:15~30 days

Specifications

1. Material is Q195(C is 0.06% ~ 0.12%)
2. Zinc coating is 40/m2 ~ 60g/m2
3. Tensile strength is 400N ~ 600N

Hot-Dip Zinc-Plating Iron Wire

Material: super carbon steel Processing by drawing, hot-dip zinc-plating Standard wire gauge from 8# to 24# Thick zinc-coating layer Super in corrosion resistance Firm coating layer Custom size available

Hot dipped galvanized wire and Electro galvanized   wire

Metric system

British System

4.0mm-0.30mm

BWG8-BWG30

Tensile strength: 30-55kg/mm2

Zinc coating: 20-32g/m2 6-295g/m2

Packing: inside   polyethylene film, outside PVC film or hessian cloth



Q:Which are more secure, wired or wireless networks? Explain.
Wired networks are always more secure because they're not advertising themselves to the world; e.g. you need to have physical access to connect to a wired network. Wireless networks can be secure; but the fact of the matter is they're advertised to any passer-by and are susceptible to having their keys cracked.
Q:I did an engine swap with some friends and everything is in place, from the rebuild 700R4 w/ a shift kit, to the rebuild 350 bored .30 over. But all I have left to do is the wiring, but have no idea how to. So about how much would it cost to have a professional finish the wiring?
Wait a sec. You recommend if Congress provides the administrative large potential to inspect on individuals, it will use it? Benghazi is a witch hunt being devised from a tragedy. it particularly is Republicans searching for political hazard. The AP surveillance is a hundred% criminal because of the fact congress exceeded a regulation announcing it particularly is under our final president. The IRS difficulty, is a localized adventure in Cincinnati, which got here approximately and became got here upon final 12 months. The operative became released. The president had not something to do with any of this. i discover the AP tale aggravating, besides the shown fact that it particularly is totally criminal. i discover the IRS difficulty troubling, besides the shown fact that it became dealt with some distance faraway from presidential notice. relax. i'm effective you will locate yet another marvelous merchandise to distract you quickly.
Q:I have 4 gauge wiring ground and power cables, as well as a smaller guage wiring that is colored grey. I have the amp hooked up to the gound and power, how do I connect the sub to the amp?The subs is a 08 L7 in the kicker truck box wired to 2 ohms. The amp is the Alpine PDX 1.600.
take (i use 12 gauge wire on my sub installs) 16-14 gauge wire and hook up the positive on the amp to the red terminal on the sub and negative to the black one. I'm not really sure what you need exactly
Q:we need to know how an electrical wire is measured. When you say for example a stranded tw wire 2mm2 does it mean 2mm square or 2 square mm meaning the area of the wire? does the measurement or size indicated in the insulation includes the insulation itself when measuring the wire? how about a stranded wire? basically the question is please explain the size of thw or tw wire stranded or solid wire indicated on the insulation. And how it is measured. does the insulation included in the measurement or just the copper wire inside that is measured.
The diameter of the conductor is generally going to be given in either gauge (AWG) or square millimeters. This is describing the size of the electrical conductor only, not including the outer insulation. Most wire specs will also include a measurement for O.D., which is outer diameter or overall diameter. This measurement will include all insulation and jacketing, and will be the total diameter of the cable. Stranded wires will be specified in terms of the overall gauge of the wire. For instance, a 22 AWG stranded wire might be marked as: 22 AWG (7x30) which means it's a 22 AWG stranded wire, made up of 7 strands of 30 AWG solid wire. See link below for more info, and conversions between AWG and square mm.
Q:How do you wire a 2 wire smoke detector directly to an alarm (no panel). The terminals are numbered 1,2,3,4 and the instructions say that 1 is for DC+ and 2 is for DC-. How do I wire an alarm so when the detector senses smoke, the alarm goes off? Thank you.
A 2-wire smoke detector? You mean one that plugs into AC? You cannot wire those into any alarm system. If you had a 3-wire (for linking multiple AC-powered units), you might be able to connect an external 120vac relay that closes the alarm contacts when the third (often yellow or blue) wire is switched on. Hardwired smoke alarms for an alarm system get a 12vdc voltage from the panel and also have a pair of dry contacts that are either normally open or (more likely) normally closed until the sensor is triggered.
Q:trying to put in a different radio, and take out the original radio, but don't know which wires are which. i tried doing it myself already, and now when i turn on my headlights, the taillights don't come on? but the turn signals come on and so do the hazards. did i snip a wrong wire or did one come loose?i only cut the wires that were attached to the stock radio.help please!thanks!
Why did you cut ANYTHING?! All you had to do is buy the aftermarket harness, connect it to your new radio and plug it in to the factory harness. I bet you cut the wires right at the harness too so you can't reconnect it. My guess would be you hooked up the dimmer wire and you don't need it. Go buy a harness anyway, it will tell you what the wires are.
Q:The resistivity of a 18.0 m long wire is 3.76E-8 Ω.m and its cross sectional area is 6.52E-6 m2. If the wire carries a current of 1.44 A, what is the voltage across the wire?
R = ( rho x l)/A Where: R is the resistance, rho the resistivity, l the length and A the area Resiatance of wire = (3.76 x 10^-8 x 18)/6.52 x 10^-6 R = 0.1038 Ohms Voltage across wire = current through wire x resistance of wire V = I x R V = 1.44 x 0.1038 V = 0.14947 V = 0.15 Volts
Q:For my braces, the top wire where my two front teeth are, I can push the wire and it sort of bend. I don't know if this is normal or not. Can someone tell me?
Yup its normal. Some of the beginning arch wires that are used are made up of very flexible metals like Nickel Titanium or Sentalloy. They are designed that way to help your teeth unravel for lack of a better term. These wires will allow your teeth to do the most movement. So no worries. But I would definitely try not to bend your wires, as you move along in your treatment some wires are not meant to be bent unless your orthodontist does it because your teeth can move in the wrong direction. Rest assured it is normal.
Q:What's the best kind of wire to use that can stand being kilned?
that really depends what you want to do and how high you are going to fire. Generally nichrome 80/20 wire should be OK until cone 9. Then there is Kanthal which will withstand even higher temperatures but is more expensive than nichrome. You could get either probably in electronics supply houses. If you do lowfire, maybe up to cone 06 or lower steel will probably be OK. The surface of the steel will oxidise and so get clearly thinner, keep that in mind. Generally your wire and the clay should not be in direct contact because they have different thermal expansion coefficients. Depends how rigid your wire is if it will lead to major damage to your piece. But if you wrap your wire with paper before you put clay around it it is probably OK as long as you don't enclose the entire thing with clay into a hollow space. But it also depends on what exactly you are trying to do, e.g. what kind of clay you are using. Mostly people use wire with clay for making beads. If that's what you are doing you can also look up bead making techniques.
Q:My home is wired for the thermostats with two wires (red and white). I have acquired a new thermostat that requires a Red, White, and Common wire. Using the white wire in that position will power the unit up but it won't trigger the heat. Is there something that can be put in line that will allow this thermostat to work without rewiring the house?
T-stat wires are usually left loose in the wall, no staples, so you can easily replace it by pulling a new wire through with the old one. First try to get an idea of where the wire goes. Get an estimate of total length and go to home depot and purchase 18-3 t-stat wire. They sell it in 25 feet, 50 feet, 100 feet, 500 feet, or by the foot. Compare prices and get enough to make a continuous run. Older 2 wire Tstats used a mercury or spring switch to simply connect the two wires together (24v + and sl return). Your new Tstat needs a common because it is being powered by the same feed that activates the unit. (So you have 24+ 24- and sl return) When you attach your new wire to your old wire be sure to actually strip the outer coating of about 4 inches or so and fold the wires around each other to get a good strong bond, and then tape it tight to keep it as small diameter as possible.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches