Specification

Colour:
red, yellow, blue, green, black Yellow-green color etc
Rated voltage:
450/750V
Specifications:
0.75~185mm²
Insulation materials:
PVC
Product:
BVR Copper Wire
Conductor material:
Non-oxidized copper core (copper content: 99.99%)
Standard:
JB8734-2012
Model:
BVR
Academic name:
Copper Core PVC Soft Wire
Number of cores:
single core

BVR Copper Wire


High quality BVR Copper Wire  with a good price


Introduction

Product: BVR Copper Wire

Academic name: Copper Core PVC Soft Wire

Model: BVR

Standard: JB8734-2012

Conductor material: Non-oxidized copper core (copper content: 99.99%)

Number of cores: single core

Insulation materials: PVC

Specifications: 0.75~185mm²

Rated voltage: 450/750V

Colour: red, yellow, blue, green, black Yellow-green color etc

Application

This product is suitable for AC rated voltage 450 / 750V and below, requiring the use of fire-retardant occasions of electrical, instrumentation, telecommunications equipment, power equipment and lighting lines fixed laying.

Features

The long-term permissible operating temperature of all types of cables shall not exceed 70 ℃. The laying temperature of the cable shall not be less than 0 ℃. The outer diameter (D) is less than 25 mm cable allowed bending radius should not less than 4D. The outer diameter (D) of 25mm and above the allowable bending radius of cable should not be less than 6D.


Model


The insulation materials and sheath materials of BVR copper wire is PVC. BVR copper wire according to the different properties, the product can be divided into insulation, flame retardant, fire-resistant three categories, different uses of different categories:


Model

DesignationUse occasion
BVRCopper Core PVC Soft WirePower, electrical instruments and automation devices
ZR-BVRCopper Core PVC Flame-retardant Soft WireWith a fire-retardant requirements of electrical, instrumentation, telecommunications equipment, power equipment and lighting lines fixed laying.
NH-BVRCopper Core PVC
Fire-resistant Soft Wire
Control, monitoring circuits, power, line protection and other occasions, as well as large-scale construction, petroleum, metallurgy, chemical industry, cable, ship, personnel-intensive industries have higher flame retardant and fire resistance requirements

 
Technical parameters


Nominal 
cross section
(mm²)
Nominal insulation thickness(mm)Upper limit of average outer diameter(mm)20℃ Maximum
conductor resistance
MΩ.km
70℃ Minimum insulation resistance
MΩ.km
Copper coreTinned copper core
0.7572.924.524.80.013
173.118.118.20.012
1.573.412.112.20.011
2.5194.17.417.560.011
4194.84.614.70.009
6195.33.083.110.0084
10497.31.831.840.0072
16498.61.151.160.0062
259810.20.7270.7340.0058
3513311.70.5240.5290.0052
5013313.90.3870.3910.0051
70189160.2680.270.0045
9525918.20.1930.1950.0044
12025919.80.1530.1540.004
15033622.20.1240.1260.004
18542724.60.09910.10.004

 
Note: NH-BVV, ZR-BVV and BVV for the same series, so the structural parameters are the same


Introduction of our company


Our company is a professional China Wire and Cable Manufacturers, mainly supply Aerial bundled cable,House Electric Wire, Insulated Overhead Cable,Aluminium Conductor Steel Reinforced, PVC Control Cables,XLPE Power Cables,BV Electric Wires,Nylon Sheathed Cable,Buried Cable,High Voltage Cable,House Electric Wire,Single Core Flexible Copper Cable,Civil Wire And Cable etc. series of wire and cable products, sincerely welcome everyone to visit.




Q: I live in a home that is 50 plus years old. All of the electrical outlets in the home are the out dated 2 prong plug ins. Are there any safety issues associate with replacing the outdated 2 prong outlet with a 3 prong outlet to power a metal halide high bay light fixture with a 400 watt ballast? The wiring in the wall is also outdated and does NOT have the up to date 3 wire electrical supply.
No the electrical code requires a ground. Run a separate ground wire to it from the metal water line coming into the home or from the ground rod from the electrical service or Telephone ground rod.
Q: Upstairs toilet water seepage for a long time, my house is a large number of walls, has been unable to discuss the argument, the recent short circuit, and suspected to be the reason for water seepage, but upstairs and his insistence, even if there is a leaking can not affect wire. Because of this ignorant, so here to ask you, leakage of water will lead to short wire inside the wall? Thank you for answering. Question added: 1: is the old house, the wire is replaced seven years ago. 2: upstairs tenants insist on not admit leaking, but also invited his decoration master to see, they say no matter what the situation, even if the water leakage will certainly not lead to short circuit. For his argument doubt, so I would like to ask, is not any case, the leakage of water will not be inside the wall bubble to a short circuit? More
BV line is a single strand of hard copper wire, BVR that is copper core cord.
Q: I was just wondering is all electrical high voltage lines including low voltage is isolated to prevent electrical shock.
Some do and some don't ! High voltage power line that runs at 20000 volts to 50000 volts is a bare wire. Lower voltage street line from pole to pole (about 5000 volts) is also bare wire. After step down by the small street transformer then feed to the house 240 volts is insulated wire. All the AC wiring inside the house carries 120 volts and 240 volts is insulated wire. Most electronic circuit board has printed circuit which has hundreds of bare wire.
Q: Can electrical wire from a 50 ft drop cord be used to re-wire the lights on a old car with a 12 volt system ?
Yes, but it is not oil and gasoline resistant and the oil base products used in the vehicle will dissolve the insulation cause a fire hazard. You need automotive rated wire because the insulation will resist oil and gasoline and the high temperatures of an automobile.
Q: I want to install two separate outdoor lights. How do I do that from one wire? How can I make one wire into two wires and what would I need? Thanks.
this can be done with a external water proof junction box, be sure you know what you are doing, you could put your self and the building at risk.
Q: Power inside L and N on behalf of what ah
The The First, the excretion of training must first start, but also the most controversial training, is to train the puppy to the house excretion
Q: does the term, home-run refer to, and what are some other common terms with a brief description plrease? thanx! jk.
Home run means it goes straight back to the panel. I have done some wiring in my house and I try to do it all with home-runs. Its far simpler and you have fewer chances to screw up. For example, you want a new receptacle on your patio. You run a wire from the panel straight to the receptacle. No boxes or splits. That is a home-run.
Q: Home decoration to use much of the wires, such as light lines, sockets, air conditioning lines, refrigerator lines
Own house or more than 4 flat, safe first! Do not consider that little investment
Q: I do not want to break any nyc code law.
Non-metallic (NM) wire also known as Romex(brand name) is used in residential wiring but must be installed according to the National Electric Code (NEC). As it says in the first section of the NEC, All codes are subject to the authority having jurisdiction Which means your local electrical inspector has the final say. Your best bet would be to call your local inspector and ask him or her if you can use NM in your application.
Q: What is the difference between a radiation wire and a wire without radiation?
Metal rail or metal tank within the total cross-sectional area of the wire should not exceed 40% of its cross-sectional area, and the metal box containing the flow of wire should not exceed 30 16mm? wire diameter of 8mm, plus the maximum cross-sectional area after the insulation are: 502mm?; truncated area = (502 × 2) / 40% = 251mm ?; trunking a × b = 251/12 ≈ 209mm, × 12 of the trough as well