High Pressure Jet Pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 35000台 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.self-priming pump2.BrassPPO impeller
3.Copper wire
4.Single phase
5.1 year warranty
1'' 0.75hp jet pumps for boats
♦PUMP
1.Cast iron pump body
2.Brass/PPO impeller
3.AISI 304 shaft
4.MAX. liquid temperature:+40°C
5.MAX.suction:+50m.
♦MOTOR
1.C&U bearing
2.Motor with copper winding,
3.Bult-in thermal protector for single phase motor
5.Protection class:IP44
6.MAX.ambient temperature:+55°C
♦FEATURES
1. CE, GS certificate
2. 100% copper wire, automatic wiring
3. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and
precision.
4. CNC precision automatic lathe for smoother shaft.
5. Strict tests include water test, outgas test and performance test, ect.
6. Anti-rust treatment castings and electrophoresis.
7. 23-year experience, 1 year warranty.
♦MIAN MARKET
America,Russia,Australia,Turkey,Egypt,Gernamy,Bangladesh,Tailand,Srilanka,Pakistan,Iran,Lebanon,Iraq,Panama, Colombia, Afghanistan, Dubai, Hong Kong, Vietnam, ect.
♦TECHNICAL DATE
- Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
- The elevator is mainly used by the power grid through the rectifier, filter, inverter and other transmission to the motor. The motor in high speed when the brake suddenly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power, the reverse voltage and torque original electric state torque instead, and the motor with brake strong torque, forcing the rotor to stop fast but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible and therefore cannot go back to the grid, energy will be accumulated in the filter capacitor, produce pump voltage, this phenomenon of pump voltage converter has great destructive power.
- Q: What is the minimum continuous flow of a pump?
- At'-- the allowable temperature rise of pumping medium,C- pumping medium specific heat, kj/ (kg DEG C);Ho- off dead center lift, M.Minimum continuous flow minimum continuous stable flow and minimum continuous thermal flow and the maximum value in the selection, or use the pump process, the minimum continuous flow process requirements must be greater than the minimum flow rate of the pump, otherwise it will cause the pump cavitation, vibration and noise, so that the pump parts damaged. If the minimum continuous flow the pump can not meet the minimum requirement's process, can install the bypass reflux device or reflux system in the pump pipeline, to ensure that the minimum continuous flow pump.
- Q: What's the pump? Where can I use it?
- Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
- Q: What are the reasons for sealing damage of centrifugal pumps?
- The reasons for sealing damage of centrifugal pumps are as follows: six, the specific contents and handling methods are as follows:First, the centrifugal pump water quality is poor, containing particles.As a result of poor water quality, containing small particles and medium hydrochloride content is high, forming abrasive wear, centrifugal pump seal plane or pull the surface, resulting in groove, ring groove and so on.Treatment method: improve water pressure or medium, replace machine seal.
- Q: What is the function of a submersible pump?Do you have any knowledge about submersible pumps?.
- The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.
- Q: Water pump does not produce water, what are the reasons?
- 1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
- Q: Is the sewage pump the same as the mud pump?
- The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
- Q: Suction stroke and lift of water pump
- The absorption process is also called the "largest self-priming height" (also can be understood as "the degree of self suction). Micro pumps do not add water at the circumstances, can automatically water suction pump up the maximum height (the vertical distance from the pump to be pumped from the mouth of pumping liquid).Generally lower than the water pump positioned equal when there is self-priming pump required capacity. For example, outdoor tourism, need to extract the water in the river, with the best micro pump self-priming ability (impossible to people ran to the river water inlet pipe with water. It) or pumping the liquid corrosion, easy to add water and so on occasions.
- Q: Metering pumps related matters
- 2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
- Q: How to calculate the motor power of metering pump?
- Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw