Technical specifications

Table 2.3: Technical Parameters of QD200 Series Frequency Inverters

ITEM

SPECIFICATIONS

Main

Input

Rated voltage and frequency

Single-phase 200V class:  200V-240V,50Hz/60Hz

3-phase 400V class:  380V-480V , 50Hz/60Hz

Allowable value of change

Voltage: 380V-15% ~ 480V+10%;  Frequency: ±15%

Main output

Output voltage

Maximum output voltage equals to input voltage

Output frequency

0.5 Hz to 400 Hz

Overload capacity

150% of rated output current for 60s, 200% of rated output current for 2s

Control performance

Modulation mode

3-phase PWM, 2-phase PWM

Control mode

V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving

Setting method of run command

Outer terminal, keyboard panel or serial communication

Setting method of speed command

Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal

Speed setting resolution

Keyboard: 0.1 Hz

Analog setting: 0.05/50Hz (10bit)

Speed control precision

V/f control:±2%

vector control without PG (open loop control): ±0.2%

Speed control range

V/f control 1:40

vector control without PG (open loop control)  1:200

Acceleration and Deceleration

Time

0-3200.0s

switching frequency

1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency

Analog input

Number

2 ways: AI1、AI2

Type

DC voltage or DC current

Maximum input range

AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable

AI2: 0 to 10VDC or PTC probe input receivable

Analog output

Number

1 way: AO1

Type

DC voltage or DC current

Maximum input range

Voltage output: 0 to 10V, Current output: 0/4 to 20mA

logic input

Number

0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2

15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2

note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic)

Type

Source or Sink

Maximum input range

0-24VDC

ITEM

SPECIFICATIONS

logic output

Number

0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C

15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C

pulse signal output

OC,output frequencycurrentoutput、ect other function

relay output

RA-RB-RC, including a NO contact and a NC contact

Maximum switch capacity:

T1A,T1B: 3A at 250VAC, or 4A at 30VDC

T2A,T2B: 2A at 250VAC or 30VDC

Serial communication interface

RS485 interface supports Modbus protocol.

Display

4-digit LED digital display

For display of frequency setting, output frequency, fault code and parameter setting etc.

Environment

Standard

Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3.

Altitude

Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m)

Ambient environment

0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating.

Storage: -25 ~ 70°C

Humidity

No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3

Impact strength

15gn for continuous 11ms, In accordance with IEC/EN60068-2-27

Maximum antipollution capacity

Class 2, in accordance with IEC/EN61800-5-1

Structure

Protection level

Top: IP41 (without removing the protective top cover). Other parts: IP20

Cooling Method

Forced Air cooling

Installation method

Wall mounted

Q: Pump frequency converter instantaneous restart and restart the problem
Speed tracking start, with them better. Speed search time is less than the free downtime, not too small too much, will be over-voltage protection. I do not understand and contact me. Your inverter voltage level, manufacturers.
Q: Laptop power adapter bad what is the phenomenon?
Either the power is bad or the machine on the power supply module is bad to repair service
Q: Octopus AC Servo motor can be driven with ordinary inverter?
If it is asynchronous motor, then take the power, voltage matching ordinary inverter drive no problem, you only need to enter the appropriate parameters, such as current, power size and other parameters, and then off-line parameters from the adjustment (if the vector control run), you can run
Q: Fuji inverter motor set the number of poles will not have any effect?
The number of motor poles set incorrectly, self-learning when the motor parameters are not correct, not the correct parameters of the motor. Inverter control speed is not accurate, and the motor will heat, can not work properly.
Q: Lenovo g450 laptop power adapter specifications is what?
Input: 100-240V ~ 1.5A 50-60Hz Output: 19V - 4.74A
Q: How do I select a drive? Which brand is better
?11, the inverter drives the synchronous motor, compared with the power frequency power regulator, reduce the output capacity of 10% to 20%, the inverter's continuous output current is greater than the synchronous motor rated current and synchronous pull the current value of the unit value product. ????12, for the compressor, vibration and other torque fluctuations in the load and the hydraulic pump and other peak load case, if the motor in accordance with the rated current or power value of the inverter, then there may be due to peak current over-current protection Action phenomenon. Therefore, you should understand the frequency of the operation of the situation, select the maximum current than the maximum current output of the inverter. When the inverter drives the submersible pump motor, the rated current is greater than the rated current of the submersible pump motor because the rated current of the submersible pump motor is greater than the rated current of the normal motor. ????13, when the inverter control Roots blower, because of its large starting current, so select the inverter must pay attention to whether the capacity of the inverter is large enough. ????14, select the inverter, be sure to pay attention to whether the protection level with the scene to match. Otherwise the scene of dust, water vapor will affect the long-term operation of the inverter. ????15, single-phase motor is not suitable for inverter drive. Recommended Ampang letter converter, domestic brand, quality and stability, first-class service, trustworthy!
Q: Laptop power adapter is used to do what
Simply put the transfer into DC China's electricity is 220V AC, and the notebook is a direct current, the need for adapter to rectify, filter, regulator, and finally we need to form a direct current
Q: Three motors, if coupled with the governor speed, is it necessary to add the inverter?
?Fifth, the hydraulic coupler speed: hydraulic coupler is a hydraulic transmission device, generally composed of the pump wheel and turbine, when the pump wheel in the prime mover driven under the rotation, in which the liquid is driven by the blade and rotation, in the Under the action of centrifugal force along the outer ring of the pump wheel into the turbine, in the same turn to the turbine blades to thrust, to drive the production machinery operation. Through different hydraulic (lubricants and turbines) to achieve speed.
Q: 90KW inverter start 90KW, 4-pole motor and 6-pole motor j What is the difference? The inverter can be used for it?
Two motors can use the same frequency converter, but the motor nameplate data through the parameters to adjust the input when the inverter should pay attention to some
Q: 380V 2 pole motor can use the inverter?
Of course, the stator winding can be connected with concentric While enameled wire to be better, preferably 180 degrees or 155, and even dedicated enameled wire