• Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation System 1
  • Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation System 2
  • Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation System 3
  • Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation System 4
Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation

Fanfold Roofing Insulation - Flexible Ducts Aluminum Foil Mylar Insulation

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
234 g/m
Supply Capability:
234 g/m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Material

 

10m length aluminum insulation ventilation duct with low priceis made of aluminum foil +fiberglass+aluminum foi+steel wire

 

 

 

Product Feature

 

8 inch insulated flexible aluminum air duct heating and cooling systems following feature:

 

1.Size.    (Customer's color requirement can be matched)
2.Color.   (Customer's color can be fulfilled )
3.Non-toxic .Harmless to people even long time exposure
4.Excellent light transmission.  transparent rate above 92%
5.Excellent weather resistance.  performance cant be change easily by Sunlight and Rain
6.Excellent Design.Personalized design and Human design with mordent concept

 


Product Advantages

8 inch insulated flexible aluminum air duct heating and cooling systems following advantages:

 

1.Material .environmentally friendly Acrylic
2.High Ruggedness.hard to attrit ,break and damage
3.Good anti-aging Properties .Long Using life Above 5 years
4.Strong Impact resistance .16 times than that of ordinary glass
5.Logo imprinting .Customer's Logo can be imprinted personally
6.OEM.ODM service. Satisfied related service can be offered in short time
7.Competitive price.Price at various level  can cater your various requirement
8.Reasonable Delivery time.Fast to arrive at your office By air or Sea  
9.Sample .Sample available for your proof and final decision
10.Trial Order are hotly welcome and allowed

 

Q: ... building code max. (R-50)???
"R" I think stands for "Resistance" factor against heat loss. It resists the heat transfer but doesn't stop it. There is no such thing as perfect insulation. Snow itself is a rather good insulator. So even though you are only losing very little heat, the snow on top of the snow directly on the roof helps trap that heat at the bottom. So the first layer will melt.
Q: I have 4 pieces (about 50 sq ft) of odd shaped polystyrene foam insulation between 3" and 4" thick. it's leftover from installing a flat roof. creative ideas anyone?
I'm a bit confused here Andy. If the flat roof needs replacing, when it is removed what is revealed is going to be exactly what you would see if you removed the ceilings. So why consider removing the ceilings if they are ok? When the flat roof is replaced put the insulation in then. Whilst rockwool would have been the material to use there is now roofing insulation board that is much more efficient, 50mm board gives equivalent insulation of something like 150mm rockwool. If the flatroof isn't fitted with suitable vents to keep it ventilated fit them when the roof is done too. The only reason I can see for replacing the ceiling plasterboard is if it hasn't got a vapor barrier ie foil backed board.
Q: Foam and the new building technolodgy's are coming to New Orleans. The rebuilding is causing New Orleans to be the "Greenest City in America". Energy Efficiency and the proper buiilding techniques tak hold.
First, "green" building is not technically defined as far as the construction industry is concerned. i.e. anyone can call their products "green" until the parameters are set up to strickly define what is "green" and what is not. To date, it's been more of a marketing strategy than anything. (Unless this has changed in recent months) I'm glad to hear New Orleans is taking the right path in rebuilding the place! Hope to get back down there soon.
Q: A roofer who wants to put a new roof on my mobile home says it will dry out. (We live in the rainiest part of the US)
If your insulation gets wet while the roof was removed, you will most likely have mold/mildew problems after the roof is replaced. While the roof is off, it's an excellent idea to inspect the insulation are replace as necessary. If your roofer isn't going to protect your insulation while it is exposed, find another roofer.
Q: How do I adequately insulate my attic roof to make the space a bit more habitable in the winter? The floors to the living area below are already insulated and we have a gable mounted fan which is great in the summer. I am thinking of adding insulation to the roof with baffles underneath for air circulation through the soffit vents. Am I anywhere near an idea that may work?
What you could do is line inbetween the roof trusses with fibre wool and then fix heavy cardboard sheets over them to keep them in place. Alternatively you could engage the services of a specialist company who will come and strip off your tiles/slates whatever and spray an insulating foam on the inside thus sealing everything in place.
Q: What is the aim of insulation in walls and in roofs?
The basic idea on insulation is to slow the movement of heat.
Q: i like to put a layer of sand in roofing instead of insulation. it's fireproof and insulates better. plus it's free. how much weight can ceiling board handle? I find about 15 inches poured into the roof works fine so far. Saves me about $1600 each house built
first sand is very heavy and will probably exceed the loading on the roof and walls the extra reinforcing you would need to make the house SAFE would far outway any savings
Q: The attic was converted into two rooms and I want to add insulation but the space between the ceiling of the rooms and the roof is about 5 inches? How should I do this?
u can buy blow in insulation. I think Home Depot even lets you rent the blower machine free if you buy a certain amount of bags of the insulation.
Q: The roof does not have fillet under tiles, our house tends to be very cold and we want to remove the insulation and put a knew one, will our house be warm? any tips and advice.thank you for your time
I was an insulation installer for a time and this is what we did. We never took out old insulation; this is even when we blew it into the walls. We used cellulose wood fiber aka recycled paper preferable news paper and phone books. After the stuff was ground up Borax and Boric acid was added to make it fire proof. This stuff was blown in on top of the old stuff, usually 6 to 8 inches. All you do is have one person in the attic who sits down, with a hose in hand you plow it in and take measurement as you move along to be sure it is the thickness you want. Try to keep it even and smooth (like icing a cake). The other person stands next to the blower, which is place outside our in the garage (ours was in the back of a truck). This person must keep the hopper full and walk from the blower to the attic to physically look at you for safety reasons. Both must were face mask over your mouth and nose, you may want to wear goggles as well. I didn’t like goggles because they fogged up. Before you start work out emergency calls and other communication. We did this by turning the blower on and off with the remote switch (which you must have in the attic). If you take the square footage of your attic to the store the sales person can tell you how much you need. This info use to be on the back of the bag and it is easy to do. Make sure you have the correct number of roof vent for the square footage of your space. Have a fun time doing it and it will be over in no time! The blowers may have the formula to figure how much you can do per square foot per hour. This will let you budget your time better, remember that formula is usually how much can be blown per hour; the other task will eat into that time frame. To do the side walls is a bit more involved, but if you need help with that as well I would be glad to tell you the details.
Q: I have a vented metal roof. WV winters
Check into heat tape tied to pipe, with insulation wrapped around that. turns on when freezing temperatures. insulation by itself, will not stop it from freezing if left for long periods without water moving through it. .