EMC XLPEFLEX Wind Energy Shielded Control Cables
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
EMC XLPEFLEX Wind Energy Shielded Control Cables
Product Introduction:
EMC XLPEFLEX wind energy shielded control cable is applicable for free hanging or fixed installation in fin cabin.
Conductor should comply with the requirements for Class 5 specified in IEC60228.
The surface of conductor should be bright and clean no grease, no burr or bulge or faulted wire to damage the insulation.Every conductor coat with an isolated layer made from appropriated material.
The nominal value of the insulation thickness shall comply with IEC60227-7. The average value of insulation thickness should be no less than nominal value, and the thinnest part should be no less than 90% -1mm of nominal value.
Insulation adopts XLPE, whose property should comply with provisions in IEC60502-1. The insulation should be rapped on conductor tightly and easy to peel without damaging the insulation, conductor and coating. The surface of the insulation should be flat and color evenly
Operating Characteristics:
• The lowest temperature that cable could work should not lower than-300C.
• Max temperature is 150 0C for short period ( 2h maximum duration each time).
• Minimum bending radius is 30 times of cable diameter.
Specification:
Altitude: 1000m
Ambient air temperature: Perennial mean temperature: 10℃
Extreme high temperature: 50℃
Extreme low temperature: -42℃
Average relative humidity: normal value for accumulated year: 80%
Earthquake Proof: Horizontal acceleration: 0.2g
Normal acceleration: 0.1g
Safety factor: 1.67
Note: g is acceleration of gravity. g=9.8m/s²
Extreme wind speed:30.0m/s
Range of Laying:
Cables mainly lay in the cabin of fan, where machinery oil may leak or overflow.
Operating Properties:
Rated Voltage U0/U: 300/500V
Continues operating temperature: Flexible: -5~+90℃
Fixed: -40~+90℃
Min. ambient temperature when laying: -5℃
Min. bending radius : Flexible:10d
Pictures
- Q: my tv is mounted on the wall, and my friend came round and we tryed to plug in his ps3 and we knocked the main power plug from the tv.we have fiddled about for around an hour looking for wer it came from and need help before my mam gets back!
- Ignoring all the upfront on-line research I undertook, I made 8 separate visits to the showrooms of the 'usual suspects' in UK electrical retail I was so torn between the sony panasonic 42 offerings!! As a brands snob I wanted the Sony because I wanted a sony on my wall.. But every time I viewed the TV's in various store environments I kept getting drawn back to the simplicity if the panasonic's operation, the depth of tone / image on screen vs. the sony. After much consideration I went for the panasonic as (for me) it's a better TV to watch TV on!.. Technically the sony has a faster refresh rate plus slightly more advanced image 'in-fill' technology and technically it should therefore give a
- Q: I need a longer power cable for my xbox 360 dvd drive, can anyone tell me where I can find out on OKorder?Or what its called? I type in dvd drive power cables on OKorder, but only the short stock ones show up I need one with about 10 inches or so.Thanks!Can these be found in radioshack?
- try looking at a game store like Game Stop or check with the manufacturer
- Q: Cable yjv-0.6 / 1kv-4 * 120 + 1 * 70 What does it mean?
- "Electrical design of civil buildings," 8.10.13; steel cable bridge straight section length of more than 30m, aluminum or glass fiber reinforced plastic cable bridge length of more than 15m, should be set up expansion joints. Cable bridge across the building deformation joints, should be set compensation device. The telescopic section is set for temperature change; the compensating device is to prevent settlement at the deformation.
- Q: I have an HP Pavilion ze5385us.... the power cable is messed up and I'd like to replace it, but the ones on the HP website are pretty expensive... I have a different computer so if I have to spend over 100 bucks then forget it. Does anyone know of a good generic brand?
- try on the OKorder and you could get cheaper and the same is about ?20.
- Q: Welding cable (230v) doesn't, so why would (14v) car audio cables
- Well....that depends on how big the amp is. An extension cord has either 2 or three wires inside at somewhere between 16 and 12 gauge wire. You could twist all the conductors together and be good up to about 40 amps with three 12 gauge wires. The issue with amplifiers is current not voltage. The thicker the wire the more current it will handle. Most any wire you buy is rated at least 120V. Check what size fuse the amp requires, if it is more than 30 to 40 amps I would buy the right size single wire for the amp. Also, fuse the wire at the battery. Fire is not our friend. :)
- Q: What is the outer diameter of the copper cable 3 * 25 + 2 * 16? What is the cable diameter of 4 * 50 + 1 * 25?
- You can use, but look at your LCD TV there is no DVI port or HDMI port, the best use of HDMI port or DVI port, the specific look at your TV size, if your TV support 1080P, it is best to use HDMI or D fans ridicule guest Piji nine Depends on the end VI, because the VGA can only 1080I can not 1080P, with HDMI or DVI display will be better.
- Q: I bought a LG Plasma TV, it comes with 3 Ferrite cores, two of them is a little bigger than the diameter of the power plug and it's not tight on it and one is small, is it effective to but the bigger one one the power cable?
- It doesn't make any difference, they are just as effective if they are loose. Actually the bigger ones should be more effective at filtering because there is more ferrite material in them.
- Q: hai am working with QATAR PETROLEUM i have one job i have to supply barrier i have the barrier power supply for barrier 120/230v which braker and which cablecore with formula i have to submit for approval regardsravi
- contained in the former days we used to partition off because of the speeds of not worry-free drives and how records replaced into saved. Now a days, distinct walls do not some thing for speed, the really authentic positives could be a million, once you've a Boot Partition, sufficiently enormous to take care of the OS, and under no circumstances set up any courses on it, then one partition on your courses, and a very last partition on your records. in case you ever favor to reinstall or format the OS, you received’t lose your records. in my opinion even with the indisputable fact that, I don’t partition some thing, I run 500GB for my important force, then use an exterior 1TB for backups. So, to respond to your question a touch extra obviously, searching on the way you've it partitioned, it can slow your computing device down, or do not some thing solid or undesirable. it received't income you in speed except from what i discussed above conserving the OS on a separate partition so it does not get affected by capacity of courses being put in and uninstalled. no count the way you examine out it, 7 drives is way too a lot.
- Q: What is the cable bucket in the power cable installation project?
- Is the separator divides the bridge into 2 and a half, usually with two different roles of the cable at the same time laying in a cable bridge, such as the power cable with the signal cable with the bridge laying, in order to avoid electromagnetic interference, with separator separation.
- Q: (for example : 1sqmm, 4sqmm, 35 sqmm) i need a formula to calculate current by knowing the area of the cable?
- This is not a simple answer. The amount of current that a cable can carry depends on the amount of voltage drop that you can tolerate (mostly an issue in long cables) and the temperature rating of the insulation used on the cable ( the higher the temperature rating, the higher the current that you can run in the cable) and the ability of the cable to loose the heat that is generated from the I^2R drop in the cable. For example, if a cable is in open air with no other heat sources near it, it can accomodate more current before compromising the insulation. If a cable is in a conduit with other cables that are generating heat, then the conductor needs to be increased in size to decrease the heat. The ampacity of the cable is also affected by the duty cycle of the current that the wire is carrying. If the duty cycle of the current is 10% then the wire can carry much more current compared to a current of 100% or continuous. Having said all this, there are tables of ampacities for various sized wires.
Send your message to us
EMC XLPEFLEX Wind Energy Shielded Control Cables
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords