• Centrifugal Water Pump with Diesel Engine for Pump Station System 1
  • Centrifugal Water Pump with Diesel Engine for Pump Station System 2
  • Centrifugal Water Pump with Diesel Engine for Pump Station System 3
Centrifugal Water Pump with Diesel Engine for Pump Station

Centrifugal Water Pump with Diesel Engine for Pump Station

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                       Centrifugal Water Pump with Diesel Engine for Pump Station

1.Structure of  Water Pump with Diesel Engine Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Water Pump with Diesel Engine

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Water Pump with Diesel Engine  images

Centrifugal Water Pump with Diesel Engine for Pump Station

4.Water Pump with Diesel Engine Specification

 

Pump TypeSplit Casing Pump
Casing MaterialHT200
ImpellerSS304,SS316,Copper,HT200
Pump SealingPacking seal,Mechanical seal
Capacity Range126m3/h~8520m3/h
Head Range8m~140m
Inlet/Outlet diameter6"(150mm)~32"(800mm)
Rotary Speed1450rmp/2950rpm/585rpm/730rpm/970rpm
NPSH(r)2.5m~7.5m
N.weight165kgs~2550kgs
Pump Parts

Casing,Pump cover,Impeller,Shaft, Double suction sealing ring

Shaft sleeve,Bearing etc

Certificate

ISO9001:2008,CE,TUV

 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: What is the difference between swashplate pump and crankshaft pump?
Piston pump: valve plate, valve plate, piston, piston ring, crankshaft, connecting rod and so on, all belong to its spare parts.Piston pump working principle: by the piston in the pump cylinder for reciprocating movement to suction and remove liquid.
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
[suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
Difference:The installation position is different: one can discharge water, one is on the ground.The work principle is different: the principle of submersible pump is similar to the electric fan, centrifugal pump through centrifugal force to make the water throw out. According to the principle of centrifugal force design,
Q: Advantages and disadvantages of centrifugal pumps?
The uniform liquid no pulse phenomenon.(2) shortcomingsBefore running, the pump must be filled with liquid.For the supply of small flow, large pressure head inappropriate, inefficient and limited.Encountered imperfect design or operation is not at the time, such as milk, it is easy to produce foam, affecting the next process production.The installation is wrong. There will be "Qi tie" phenomenon.The efficiency is also lower than the reciprocating pump.The sources of knowledge are absolutely reliable!!!!
Q: Does the reservoir water heater press the booster pump (high marks)?
The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
Q: What is a positive displacement pump? He Weizheng displacement?
The principle and structure of positive displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow.
Q: Is the sewage pump the same as the mud pump?
Two of the main performance parameters of mud displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement. The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.Sewage pump is mainly used for industrial wastewater treatment, sewage treatment, environmental protection has played a big role. Among them, the sewage pump is also a sewage pump with cutting wheel, such sewage pump can be chopped dirt, and then extract the sewage clean.
Q: Common failure treatment of piston pump
x09x09 (3) no connecting key on pump shaft or motor shaft1) break2) missing x091) replace key2) patch keyx09x09 (4) pump internal slide vice stuck1) the clearance is too small2) parts accuracy is poor, assembly quality is poor, gear and shaft coaxial deviation is too large; plunger head clamping; blade perpendicularity difference; rotor pendulum difference is too big, rotor slot has wound or blade has scar, force after fracture and stuck
Q: How many concrete pump tube diameter
Different pipe diameter is different, most of the 125, there are 150. Now we have the smallest pump on the market, with a pipe diameter of 100.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords