Centrifugal Water Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
PRODUCT INFORMATION
WQ series submersible non-clog sewage pump in the introduction of foreign advanced technology, based on the joint efforts by our researchers, while a wide range of suggestions from pump experts, and after many improvements and successfully developed, tested each Top performance indicators are that the advanced level of similar foreign producing countries. Used in chemical, petroleum, pharmaceutical, mining, paper industry, cement plants, steel mills, power plants, coal processing industry, and urban sewage treatment plant drainage systems, municipal engineering, construction sites etc sewage particles, dirt, can also be used to pump clean water and corrosive media.
Model significance
50WQ (QW) 25-32-5.5
50 caliber 50mm exhaust ----
WQ (QW) --- submersible sewage pump
25 ---- flow of 25m3 / h
32 ---- lift 32m
5.5 --- with motor power 5.5KW
Performance range
Flow: 7-950m3 / h
Head: 7-35m
Features
1. When using a unique monolithic or double blade wheel structure, greatly improving the living creatures capacity, can effectively through five times the diameter of the fiber material and pump caliber pump diameter of about 50% of the solid particles.
2. Mechanical seal with anticorrosive hard softening tungsten materials, can pump more than 8000 hours of continuous operation safety.
3. The overall structure is compact, small size, low noise, energy-saving effect is remarkable, easy maintenance, no need to build pumping stations, poured into the water to work, greatly reducing the project cost.
4. The pump seal oil chamber with high precision interference leakage detection sensors embedded in the stator windings of the thermal components, automatic protection of pump motor.
5. According to user needs with automatic control cabinet, the pump leakage, leakage, overload and overtemperature protection automatically improve product safety and reliability.
6. float switch can change depending on the desired level, the automatic control of pump start and stop, without special care, extremely easy to use.
7.WQ series according to user needs with double rail automatic coupling installation system, install it to bring more convenient maintenance, may not have to get into the sump.
8. be able to use in the whole head, but to ensure that the motor is not overloaded.
9. There are two types of installation, fixed automatic coupling installation system and traveling free installation system.
FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your company?
A world class manufacturer & supplier of castings forging in carbon steel and alloy steel,is one of the large-scale professional investment casting production bases in China,consisting of both casting foundry forging and machining factory. Annually more than 8000 tons Precision casting and forging parts are exported to markets in Europe,America and Japan. OEM casting and forging service available according to customer’s requirements.
②How to guarantee the quality of the products?
We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.
③How long can we receive the product after purchase?
In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The pecific time of receiving is related to the state and position of customers.Commonly 7 to 10 working days can be served.
- Q: Know flow and lift how to calculate the pump power?
- P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm works by changing the size of the diaphragm. When the cup is covered with an eraser and the edge is airtight, then pressing the rubber or pulling the rubber outward will make the pressure in the cup increase or decrease. Use this principle, in the pressure of an hour from a hole suction medium, when the pressure is large, from another hole extrusion medium, so as to achieve the purpose of conveying.
- Q: The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
- Difference:The installation position is different: one can discharge water, one is on the ground.The work principle is different: the principle of submersible pump is similar to the electric fan, centrifugal pump through centrifugal force to make the water throw out. According to the principle of centrifugal force design,
- Q: Why can't the inlet of centrifugal pump be negative pressure?
- Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- In a dead head will be relatively high, the main downstream equipment and pump, if a dead head high, so the design pressure of the pump needs downstream equipment will be relatively large, resulting in the cost increases, so close a better head lower dead point.
- Q: Does the reservoir water heater press the booster pump (high marks)?
- In addition, the water storage electric water heater has a safety valve is O.7MPa, before buying a booster pump, you can check the water inlet valve spring weakness, see the effect of water, barely even, then use it, do not buy.
- Q: Common failure treatment of piston pump
- Table 15 common troubles and treatment of hydraulic pumpsFault phenomenon, x09 cause analysis, x09 elimination method(1) the pump does not carry oil; the x091. pump does not turn x09 (1); the motor shaft does not rotate1) missed connection power supply2) electrical wiring and component failure, x09 check electrical and troubleshootx09x09 (2) motor heating trip
- Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
- Related concepts of hydraulic motorsFlow theoretical volume refers to the volume of oil inhaled in unit time without leakage.
- Q: What is the difference between an air pump and a water pump?
- Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- Centrifugal pumps are vertical, horizontal, single-stage, multi-stage, single suction, double suction, self suction and other forms. The centrifugal pump drives the water to rotate through the high speed rotating impeller blade, and the water is thrown out so as to achieve the purpose of pumping water. The impeller rotates at high speed, forcing the liquid at the center of the impeller to be removed at high speeds, resulting in a low pressure at the center of the impeller, and the liquid in the lower trough is continuously sucked.
Send your message to us
Centrifugal Water Pump for Sewage Water
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords