• Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China System 1
  • Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China System 2
  • Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China System 3
  • Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China System 4
Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China

Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
10 m.t.
Supply Capability:
3000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Black Annealed Iron Wire Description

Black Annealed Iron Wire is very good for Chain link fence, fencing mesh, gabion mesh box production and for construction business as tire wire, binding wire and galvanized wire raw material production.Our wire is of good quality and nice price. widely used in the construction industry, handicrafts, woven wire mesh, product packaging and day-to-day civilian fields. Black annealed wire can be used in building construction , making wire mesh , fencing , and tie wire .

Black Annealed Iron Wire and steel wire mainly used in construction, mining, chemical, mesh welding, welding hanger, re processing etc.. After the process of annealing wire become soft, pliable degree increase, do construction tie wire, binding reinforcement effect more.

2.Main Features of Black Annealed Iron Wire:

Wire diameter:BWG4-BWG28 /0.35MM-6.0MM

Elongation: 10%-25%

Tensile strength:  30-70kg/mm2  

Packing:0.3kgs-500kgs/roll


3. Black Annealed Iron Wire Images

Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China

Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China

Black Annealed Wire Binding Wire Tie Wire Soft Real Factory in China


4.Black Annealed Iron Wire Specification

Wire sizesSWG(mm0BWG(mm)Metric(mm)
84.064.194.00
93.663.763.70
103.253.403.50
112.953.053.00
122.642.772.80
132.342.412.50
142.032.112.10
151.831.831.80
161.631.651.65
171.421.471.40
181.221.251.20
191.021.071.00
200.910.890.90
210.810.8130.80
220.710.7110.70


5.FAQ
 

①Are you a factory?

Yes, We are a professional manufacturer of wire in China. The Mainly product is electro galvanized iron wire, black annealed iron wire, wire nail. Our company is built by two boss, one own a black annealed wire factory,the other own a galvanized wire factory.


②Is your company offer the sample?

Of course, our factory could supply the sample for free. 


③What does the material of your wire?

The mainly material is Q195 wire rod, based on its good performance in drawing and widely using specification. And also we could change the material as your requirement.


Q: I have a 2002 Chevy blazer 4.3 motor we'll I found some wires that look like trailer wires on the back of the car and I'm trying to connect a 4flat trailer plug in. So the wires are following on the car. Yellow is left blinkerGreen is right blinkerBrown is running lights Blue is brake lightsWhite groundSo the 4 flat wires are as following White groundYellow is left turnGreen is right turnBrown is taillightsSo my question is how can I get my brake lights and running lights on the trailer plug in. Cause I have 5 wires on my vehicle and only 4 on my trailer plug. Please help
On okorder /... also available at your local auto parts store
Q: the 2 wires that is connected from the key hole is cut .. how to fix or replace?
If there enough wire left on each side of the cut, say 1, then you could bear about 1/4 of the wire on each side and solder the wires back together making sure you are soldering the same wires together and wrap each soldered connection in electrical tape so they are not able to touch each other. Then a final wrap of tape around them both. If you are not up to soldering you could go to an auto parts shop and get a crimp connector to do the job, again bearing of wire is needed to get a contact through the cut area. If the cut is closer to the switch then there is no option but to replace the switch.....
Q: do speakers function better with thick or thin wires??
It depends. If you are just gonna wire the speakers and just play it with mid volumes or normal operating volumes. these wires weather thick or thin doesnt matter. but if you want to push the speakers to it's potential, you need a good quality wiring kit. mostly these are guage 4-8 wires or thick wires of course thicker wires more current it can handle .
Q: Hi,I'm trying to connect a Panasonic CQ RDP200-LEN car radio. Normally,there is red and yellow wire for ignition and constant,and a black wire for ground. However,this unit has 2 yellow wires,2 black wires and a red. Where do these wires go? thanks
Honest answer is to take it to a audio specialist. finding and wiring a stereo from scratch (termed hardwiring) is a hard job even for the most advanced audio specialist. This is speaking from experience. Most wires are not colour coded and you will need a amp meter to measure the current, voltage, continuity and resistance in order to find out what wire does what. One wrong wire could mean new speakers or in the worst case set fire to your car. I've have done hardwires for over 5 years, and I've seen some real mess, which quite possibly could have been avoided for a few quid but impatience and inexperience has lead to new cables, trim and other pieces which were damaged due to bad installations. Please be careful!! added 9/11/06: (Note To other answeres) Don't use Choc connections or block connectors for wiring stereos as these are open connections with exposed areas of metal if they came into contact with earthed chassis they can cause a short try using bullet style or butt connectors they are more secure and sheilded!
Q: I have some salvaged wire from a computer power supply and would like to know it's break-down voltage rating. Most hookup wire is rated at 600 volts but unfortunately, all computer stuff is now made in China. The repair job of a vintage piece of equipment requires wire that can withstand 300 VAC.
Computer power supply cables do not deliver anything like 300 volts, so I would say no, don't risk it.
Q: Is there anything else I could use to solder things without buying whole long spool of soldering wires? I mean like the wire inside the TV antenna cable from 99c store or nails and etc. ? Something I could use single time.
I need a decent anwer
Q: Hello, I have a 4 year old Trane XR12 unit. Recently the compressor fan is noisy, and now stops when when under power after 5-10 min. The main fuses and breakers are fine, the fan spins freely when turned, the contactor pulls in fine, the dual capacitor checks out. But, the wiring of the capacitor does not match wire diagrams. Could this have caused the fan motor to prematurely fail?..............................Terminal: C red wire, FAN brown wire, HERM has both orange and purple. Schematic shows the purple wire should be with red wire on common C. The purple also leads to fan.
Hi, I looked at the schematic on-line. If you still have the original fan motor in the unit then you are correct. The center terminal on the capacitor should have the red wire from the T1 terminal of the contactor, the red wire from the compressor, and the purple wire from the fan. The FAN terminal should have the brown wire from the fan. The HERM terminal should have the orange wire from the compressor. The black wire from the fan and the black/blue wire from the compressor should lead back to the T2 terminal of the contactor. Again, that is if the motor is the original motor. If it was replaced at some point in time, the wiring colors can change from manufacturer to manufacturer, in which case it's possible that the new motor is wired correctly. There should be a diagram on the motor to show you the correct wiring configuration.
Q: 1980 ford f150 300 engine i need the wiring specs for the back lights thank you for any answers
what okorder and go to the repair manual section.. Autozone has older (10 years or older) vehicle repair manuals online.. check it there as most include the wiring diagrams
Q: My house is currently wired using Cat-5 lines. If I were to replace the Cat-5 wiring with Cat-6 wiring, would I see an increase in my DSL speed?
Short answer is no. The reason is Cat-X is category then a number, the number meaning twists per inch. The twists help keep out crosstalk and interference. Rarely an issue in most households and even reasonably sized businesses.
Q: I want two lights on two 3-way switches.1. Power from basement box into light #1 with 12-2 wire. 2. Another 12-2 wire from light #1 to light #2.3. A 12-3 wire from light #1 to switch #1.4. Another 12-3 wire from light #2 to switch #2. Will this do it?
nevermind what I think....the guy under me knows EXACTLY what he is talking about! Do it exactly like he says. His way is better than mine was, honestly, because he has more experience. Thats why I deleted my own answer----we call that professional courtesy to seniority and its what electricians do when someone has more experience than we have speaks up. Now it doesnt matter what I think....I only have 22 years experience and someone with more experience than I has given better, sounder advice than I did. You should listen to him, not me.......or anybody else whom cannot match or exceed his experience. Or didnt you know that all Electricians are part of the same Brotherhood? This is why we always agree (or agree to be wrong). I was wrong, obviously, and my advice, second rate, compared to the advice you are about to get. So.....Pay attention! Wisdom follows!!!!

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords