Automatic Revolving Door - Russian Seasons Hotel
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: | Brand Name: | Model Number: | |||
Open Style: | Position: | Surface Finishing: | |||
Type: | Sliding Door Type: | Door Material: | |||
Size: | Hardware: | Surface treatment: | |||
Standard: | Glass: | Opening pattern: | |||
Profile color: | Style: | Aluminum thickness: | |||
Name: |
Packaging & Delivery
Packaging Detail: | Packing of automatic revolving door 1. With carton+poly foam packing 2. With wooden pallet packing 3. Other packing methods by your requirement |
Delivery Detail: | 15-35 days after confirm the order |
Specifications
Revolving Door, Automatic Revolving Door
AUTOMATIC REVOLVING DOOR STANDARD FEATURES | |
System | Automatic |
Emergency Stop Button | 1 per entrances and exits |
Handicapped Button | 1 per entrances and exits |
Radar | 1 per entrances and exits up to 2200 mm passage width |
2 per entrances and exits from 2201 mm passage width | |
Presence Sensor | Optional for 4-wing up to Ø2400 mm, 3-wing up to Ø2800 mm |
Standard from 4-wing Ø2401 mm, 3-wing Ø2800 mm | |
Passage Height | 2200 mm |
Canopy Height | 300 mm |
Curved Glass | 4+4 Laminated (1,52 mm PVB) |
Wing Glass | 4+4 Laminated (1,52 mm PVB) |
Active Hand Jamming Buffer | Right fixed leaf |
Passive Hand Jamming Gasket | Left fixed leaf |
Lock | Manual lock |
Roof | MDF cover for indoor |
Aluminium sheet for outdoor | |
Brush | 40 mm Horsehair |
Ceiling | 12 pieces of aluminium sheet (1,5 mm thickness) |
Led Spot Light | Diameter 2000-3500 mm : 4 pieces (5x1W) |
Diameter 3600-4200 mm : 4 pieces (8x1W) | |
Diameter 4201-6000 mm : 6 pieces (8x1W) | |
Installation | On finished ground |
Glass Gasket | Epdm |
2 wings automatic revolving door was an unique revolving door with " 3 in 1 function ", that's Revolving door +Sliding door+ Balanced door, they are suitable for the door area which is much wider such as 3600mm, 4200mm or 4800mm.
Safety functions:
1, Drum wall load-bearing structure
2, Emergency stop
3, Handicap function
4, Anti-squeeze function
5, Anti-strike function
6, Force-sensitive Control.
7, Torque Control Function.
8, Safety Relay
9, Panic breakout.
10, LED Panel .
Specifications:
Inner Diameter (D) | 3600mm | 4200mm | 4800mm |
Outer Diameter (OD) | 3680mm | 4280mm | 4880mm |
Total Height (TH) | 2640mm | 2640mm | 2640mm |
Clear Height | 2300mm | 2300mm | 2300mm |
Canopy Height | 340mm | 340mm | 340mm |
Models:
Automatic Revolving Door Unit with 3 or 4 wings. Available in the following model sizes (delete as applicable)
3 Wing 4 Wing
1800mm Diameter
2100mm Diameter
2400mm Diameter
2700mm Diameter
3000mm Diameter
Standard equipment:
• Automatic drive
• Control unit built-in behind the fascia above the inside entrance Microprocessor controlled with plug-in modules and LED status lights
• Speed control
• Vertical safety switches
• Glass in drum: 8 mmclear laminated
• Glass in wings: 6 mm clear laminated
Other types of glass available
• Door sections made from aluminium profiles
• Ceiling made from white laminated panels
• Dust protection roof made from white laminated panels
Accessories and Options: (Delete as applicable)
• Powder-coated finish (RAL colours)
• Anodizing, clear or bronze
• Stainless steel cladding
• Emergency stop
• Electro-mechanical lock
• Mechanical lock on door leaves
• Fascia, non-standard height (300 - 1300mm)
• Internal height non-standard
• Sheet metal sandwich panel instead of glass
• Spotlights
• Water-resistant cover
• Rotation brake
• Emergency break-away system
• Midrails on door leaves
• Additional safety on rotating part
• Air curtain
Our quantity of Euipments are the No.1 in China
- Q: Whether the fire door is a revolving door or a sliding door
- The one who is chosen as the recommended answer may be right. But I would like to ask the fire door is the door of the revolving door also push the door of the problem when people are like me to learn the same information. Because the fire door belongs to a special kind of door, but fill in the special door inspection batch quality acceptance record table, his general project only sliding doors and revolving door 2 quick general project, so to determine the next fire door is sliding Automatic door or revolving door? From the top down on the fourth floor of the answer gave me the answer Fire doors should be regarded as a revolving door. The situation is not the same can only be so forget
- Q: Automatic door trademark category
- Hello, belong to the sixth class 0603 similar group, hoping to help you to adopt
- Q: House to be renovated, want to be in the living room. Bedroom with some induction door, the specific price is not clear who can provide some information! The Thank you
- I suggest that is calculated separately, for you more cost-effective. How much money the host, the number of dollars how much money the glass. Channel with stainless steel edge how much money in fact the general induction door to do down the words of 8 square or so had to 9000-10000 or so. This is my reference price for you. This is the host of domestic production. The difference in imports is big
- Q: The main requirement is that if someone or a car or the like to achieve the automatic stop to prevent the folder hurt people? Microwave radar is the displacement of the object response, and thus the reaction speed, suitable for people walking through the normal speed of the place, it is characterized that once the door near the staff do not want to go out and still do not move, the radar will no longer react, automatic The door will be closed, the door machine has a certain protective effect; Infrared sensors react to the presence of objects, regardless of whether the person moves or not, as long as it is within the scanning range of the sensor, it will react to the outgoing contact signal. These two that can be better, ask everyone to give an opinion! thank you very much!
- You know the infrared is what you say, I know the automatic door industry infrared night vision detection displacement, but the microwave is used in the band, the infrared is infrared. The You recommend the installation of safe light, similar to the kind of elevator things
- Q: Automatic door motor model is generally what, how to choose the motor?
- Automatic door forum has your answer
- Q: Automatic door and access control system plus remote control plus sensor can you
- This is possible, as long as you add the controller and the sensor inside the module can be a module, but the module will own to buy,
- Q: There is no relevant laws and regulations stipulated 'when the fire, the automatic doors need to automatically open' some brothers speed help out
- "When the fire, the automatic door to automatically open", have not seen such a requirement, you are not want to understand some of the installation of the access door to escape the fire in the relevant provisions of the fire. "Building design fire safety regulations" GB50016-2006 in the 7.4.12 of the provisions of Article 4: personnel-intensive places usually need to control the discretion of the evacuation door, or with access control system of residential buildings outside the door, should ensure that the fire No need to use any tools such as keys can be easily opened from the inside, and should be set in a prominent position logo and use tips. ???? If the fire door, then it is required in the fire is in a closed state, requiring the doors of the door closer function, that is, people through the door, the door can be automatically closed in time, the only way to achieve fire partition and smoke effect. Is in the architectural design fire safety specification is required to close instead of open!
- Q: and why do they even have the ones that you manually open?
- Our grocery stores don't even have manual doors unless the electronic ones aren't working. Then you have to manually open it.
- Q: I got the automatic garage door opener replaced a month ago. About a week ago the spring broke. I ended up removing the broken spring. At this point I have one spring working. The garage door still opens and closes automatically for me. What is the purpose of these springs and will the garage continue to open automatically if I don't fix the one spring?
- Another thing you need to do annually is go to Lowes/HD and go to the garage door aisle and get a can of garage door lube. I highly recommend. I had to replace a gear unit on my G-door. Buy it, put on a mask, spray it, and listen to how smoothly your G-door runs afterwards. But, yellow led on your G-door sensor, probably time to consult manual (hope you saved/filed). Or go where you bought and ask about yellow led. Good luck.
- Q: I am partially sighted, and I have never boarded a train before. I have to catch three trains tomorrow, and I am not sure if I have to search for a button/handle to open the train door?
- When the train arrives in the station the door mechanism is released by the guard or driver. It is then necessary to press a button located just to the side of the door to open it, or in the case of the Inter City 125 trains, a handle on the door. Do please ask for help from station staff at the stations where you board and alight and or the guard or train manager on the train. If on future journeys you contact the train company concerned 24 hours before your journey, they will provide specific staff members at the stations to assist you
Send your message to us
Automatic Revolving Door - Russian Seasons Hotel
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords