KA023 - 3/4 WingsRevolving Door

The designs for revolving doors provide an imposing entrance to anybuilding, while serving as an airlock as well, to minimize a building’s heatingand air conditioning losses, therefore maximizing energy savings. The bestselling model called KA023 3/4-wing revolving door is not only elegant but alsoeconomical and practical.

Safety functions:

1. SpecialLoad-Bearing Structure

2. Vertical/horizontalsafety switch

3.Anti-squeeze

4.Anti-strike

5.Force-sensitive Control

6. TorqueControl

7. Panicbreakout system

8. Handicap

9. NightSecurity Door

Operation features:

1.Continuous working mode

2.Go/Stop working mode

3. Remotecontrol function

Technical Data:

Powersupply : 220VAC±10%,50HZ

Ratedcurrent :12VAC,50HZ

Ratedpower : 600W

Downlights : 400W

Highspeed adjustment range(revolving door) : 1-4r.p.m.

Low speedadjustment range(revolving door) : 0.5-1.5 r.p.m.

Ambienttemperature : -30 - 45 degree

Maxrelative humidity : 90%.

Totalweight :  <1000Kg

Operatingnoise : <= 60db (A)

Specifications:

Inner Dia(D)

1800mm

2100mm

2400mm

2700mm

3000mm

3600mm

Outer Dia (DT)

1880mm

2180mm

2480mm

2780mm

3080mm

3680mm

Clear height

2300mm

2300mm

2300mm

2300mm

2300mm

2300mm

Canopy height

300mm

300mm

300mm

300mm

300mm

300mm

Total height

2600mm

2600mm

2600mm

2600mm

2600mm

2600mm

Key Components:

1. Maincontrol unit : SIEMENS from Germany

2.Operation program software : KBB

3.Transducer :  SIEMENS

4. Driveunit :  SIEMENS

5. Gearbox : Sewdrive

6.Deceleration belt :  CONTITECH

7. Spotlight : PHILIPS from Netherlands

8.Detection radar : Infrared, BEA from Belgium

9. Highprecision speed /position radar : HENGSTLER

10.Emergency stop button : KBB

11.Handicap button : KBB

12.Curved glass : YAOPI, security laminated glass

13.Planar glass: YAOPI, security laminated glass

14. Aluminiumframe profile : JIHUA

Note : Similar with KA023, we hadanother model of 3/4 wings revolving door called KA061,different from KA023,there are several obvious pillars outside of  KA061 which covered the gaps on the doorsurface and make the whole door looks more aesthetic .


Q: Won't automatically open when you approach it?
Not scared, but sometimes it's embarassing when they don't open fast enough and you have to slow down to let the door open.
Q: Like do they sense human? Or like heat?But… what if I throw a chair at it? Would it open?!??But what if I paint myself invisible and carry a chair through. Would it sense us, or just the chair?
If somebody has limited use of their palms and better physique, they could no longer be waiting to do it in any respect with out advice from different human beings or contraptions put in on the door itself. yet whilst they're utilising a motorized chair, they may well be waiting to diminish back as much as a door and push it open with the chair. Or, if a knob desires turning they may well be waiting to get close adequate to show the knob at the same time as advancing the chair in the process the door. All of this is extremely, very perplexing of direction, so in places that have not have been given federally or state mandated get admission to for the disabled, human beings could place self assurance in different human beings to help them.
Q: I just picture on the 8051 chip, the infrared sensor automatic door map, so I am in the extra points The following answer to the uncle to find to find you why ..... hope to help me to design or find a can
8051 chip is what stuff? Automatic door should be what brand + what model.
Q: It's the &amp;quot;AutoLoc&amp;quot; brand. If anyone has that brand... please let me know! thanks!
Automatic Lambo Doors
Q: When the vehicle reaches 15 mph, the doors automatically lock. I'd like to know how I can disengage this feature.
This feature can be enabled and disabled using computer equipment at the dealer.
Q: Automatic door and access control system plus remote control plus sensor can you
This is possible, as long as you add the controller and the sensor inside the module can be a module, but the module will own to buy,
Q: Can the fire door be replaced by an electric door?
The fire access door must be ready to be pushed at any time to be pushed outside. So, as long as you can always open, set the automatic door is possible. But turn the door, the shutter door is not enough, be sure to set the door or shutter doors, only in the side next to set out to open the door.
Q: Here is my situation. We have an automatic garage door. Two people use the garage, we both have garage door openers as well. Other than the garage door, the only other entrance to the garage is always locked. The garage door has been discovered open three times now, when both garage users are certain they closed the garage door. We need to figure out what the issue is so our cars stop being vandalized. Any ideas?
Another quick possibility: There is also something known as phantom operation. This is when there is something in proximity to your opener that is on a similar frequency to your remote control and causes the door to open unintentionally. This problem is remedied by one of two means: (1) clear out the receiver's memory and re-code all remotes or (2) purchase a new receiver/remote kit to use on your opener. If everyone is certain the door was completely closed when they left this could very well be the issue. Have a merry CHRISTmas!
Q: There is no relevant laws and regulations stipulated 'when the fire, the automatic doors need to automatically open' some brothers speed help out
"When the fire, the automatic door to automatically open", have not seen such a requirement, you are not want to understand some of the installation of the access door to escape the fire in the relevant provisions of the fire. "Building design fire safety regulations" GB50016-2006 in the 7.4.12 of the provisions of Article 4: personnel-intensive places usually need to control the discretion of the evacuation door, or with access control system of residential buildings outside the door, should ensure that the fire No need to use any tools such as keys can be easily opened from the inside, and should be set in a prominent position logo and use tips. ???? If the fire door, then it is required in the fire is in a closed state, requiring the doors of the door closer function, that is, people through the door, the door can be automatically closed in time, the only way to achieve fire partition and smoke effect. Is in the architectural design fire safety specification is required to close instead of open!
Q: Garage door stops about 12&amp;quot; above garage floor both, opening and closing. One of the sensors has a yellow LED...tried to realign and adjust manually, could see that alignment was ok, but sensor light still yellow and problem persists...wife is on me and the baseball playoff are on, please help...
Another thing you need to do annually is go to Lowes/HD and go to the garage door aisle and get a can of garage door lube. I highly recommend. I had to replace a gear unit on my G-door. Buy it, put on a mask, spray it, and listen to how smoothly your G-door runs afterwards. But, yellow led on your G-door sensor, probably time to consult manual (hope you saved/filed). Or go where you bought and ask about yellow led. Good luck.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords