• Roofing Insulation Products:Aluminum Foil Foam Insulation with Overlap in Rohnert Park, CA System 1
  • Roofing Insulation Products:Aluminum Foil Foam Insulation with Overlap in Rohnert Park, CA System 2
Roofing Insulation Products:Aluminum Foil Foam Insulation with Overlap in Rohnert Park, CA

Roofing Insulation Products:Aluminum Foil Foam Insulation with Overlap in Rohnert Park, CA

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
46000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

This is a new environmentally friendly aluminum foil bubble heat insulation material, which is soft, light and easy to install. It is made from aluminum foil and polyethylene through special machinery.

Function:

Can be installed on roof, wall or floor, resist over 80% external heat from buildings, protect wall, resist thermal shock and sudden cold, etc.

Characteristics:

1.No odor and toxicity, environmentally- friendly;

2.Moisture barrier, sun-proof, waterproof, good sealing property, heat preservation, energy saving…

3.Heat reflection, heat insulation, sound insulation, anti-radiation, anti-vibration, and shielding;

4.Light, soft, dust free, fire retardant, easy to install;

5.Summer: moisture barrier, sun-proof, heat insulation, saving energy consumed by cool air conditioning ;

6.Winter: heat preservation, central heating saving, and remarkable energy-saving effect.

Product: fireproof material

Technical parameters:

Material structure: AL/XPE/AL



Roll size: 1.35M W*22.25M L (can be customized)

PROPERTIES

Test Data

Unit

Thickness

3.5

MM

Weight

256

G/M2

Emissivity

0.115

COEF.

Thermal conductivity

0.034

W/M0

Apparent Density

85

KG/M3

Reflectivity

95-96

%

Water Vapour Transmission

0.013

G/M2 KPA

Corrosion

Doesn't generate


Tensile strength (MD)

16.98

Mpa

Tensile strength (TD)

16.5

Mpa


Usage:
1. Roof, wall, floor;
2. Shells of air conditioner and water heater;
3. Protective coatings of water pipe and ventilating pip



Q: do I have to blow insulation in the roof of my mobile home if I install foam insulation under a meatle roof?
Vapor barriers always go on the heated side of walls or ceilings. If you are going to add insulation to your attic and don't want to put in more blown in insulation ( which does have a better R-factor) then purchase unfaced fiberglass insulation to put on top of existing insulation. The thing you need to avoid is called double vapor barriers. Years ago when the first started playing with super insulated houses they would put a poly on the inside and outside of the walls. What happened is any moisture picked up in the walls going from summer to winter would get trapped in the walls and rot them out. No matter what only one vapor barrier on the heated side of the insulation!!! Then your house can breath and release moisture regardless how thick your walls or ceiling.
Q: I have a low pitched roof so there isn't that much room up there hands and knees only.I have no eave ventilation but the ventilation is through the front and back of the house through triagle metal caps cut into the wood siding. I already have some R19 in the ceiling joists but was wondering would putting it in the rafters against the plywood holding the shingles also help insulate the living area of the house.
No blowing in some insulation will help but putting insulation against the roof wont help. the attic area is supposed to breath to avoid condensation and overheating. The only thing you would put on the roof side would be to help cooling in summer since the shingles heat up the wood underneath and heats the attic, which then works down through the ceiling.
Q: ... building code max. (R-50)???
The roof can also be heated enough to melt snow/ice by the sun. I wouldn't assume it's being caused by heat escaping from inside. That said, just because you have R50 doesn't mean it's perfect - it's not. Some heat will still escape. Prefect insulation is not feasible.
Q: should thermal insulation ever be applied directly to the underside of a roof top?
yes its done all the time on metal buildings. works well but expensive.
Q: roof was replaced eight years ago soon after there were leaks in the roof caused insulation toget wet then dry now the insulation is packed hard and has started to turn into power who would be responsible to replace the insulation.
Only you. 8 years is long past any roofer's warranty
Q: does insulation, with a high R value, in the attic prolong the life of the shingles on the roof.
No. Ventilation prolongs the life of a roof. Ventilation also reduces the air conditioning bill by a huge amount. If you use a lot of AC, also add an automatic attic fan. As for insulation, the idea is to have a good R factor, relative to where you live, directly above the highest living space ceiling in the house
Q: I gutted the room and now would like to rebuild. One side of the room slants (it's the roof) and the other side of the room is a dormer (all low ceilings).I want to insulate the ceiling but have no ridge vents so no moving air as someone mentioned I should have. I want to install foam channels to keep the insulation away from the roof but not sure if this is a good idea without the ridge vents. I will have a vent to the outside installed on the very top of the roof however and the small attic space is open all the way through the other two upstairs rooms and I will add another roof vent on that end of the house. I will only be able to install 3 inch insulation but that's better than none at all. I live in the northeast and was told if the job isn't done right I can get ice jams in winter. Also I don't see any way to drill ridge vents. would it be ok to just install the styrofoam channels and insulate then sheet rock or am I asking for trouble? Thanks in advance for any help.
Suggestion: install the insulation with the foam channels but leave the center section (roof ridge area) open from end to end. At each end you can install a static vent or an active one. Depending on the amount of space you have you may be able to install a power vent.If you can send me a diagram with measurements I can give you a more definitive answer.
Q: We had a water leak in our pipes in our foundation and had to re-route our pipes along our roof. We have tried some really basic insulation for piping, but it usually deteriorates very quickly due to sun light and wind. What are some ways we can insulate our pipes effectively without having to re-insulate every month? This has to be something fairly simple and inexpensive. We aren't looking for perfect insulation, just something that will keep the water warm in the winter and cool in the summer.
Contact a local remodeling contractor and install the new piping system properly. Even a system under a foundation can be repaired, but it is not cheap to do it.
Q: we want to put a model railway up in the loft,and i like the idea of having white plastic cladding throughout up there,my hubby is insulating the roof tomorrow,but he prefers plasterboard,at least the cladding will be maintenance free,
i think it might be able to pass code if you ever sell the house.i myself would use sheets of white wainscoting.also make sure the insulation if it has a paper backing ,paper faces the room.
Q: What are the roof insulation materials?
Compared with EPS sheet, XPS board is made of polystyrene resin and other additives by extrusion process has a continuous uniform surface and closed-cell honeycomb structure of the plate, the closed-cell structure of the insulation material can have different The pressure (150-500Kpa) also has the same low thermal conductivity

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords