• AC Solar Water Submersible Pump for Irrigation Purpose System 1
  • AC Solar Water Submersible Pump for Irrigation Purpose System 2
  • AC Solar Water Submersible Pump for Irrigation Purpose System 3
AC Solar Water Submersible Pump for Irrigation Purpose

AC Solar Water Submersible Pump for Irrigation Purpose

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.  Description of solar pumps. 

CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.

 

In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

 

2. Technical Function

1>  High efficient DC brushless motor requires less solar array. Rich social benefits.

2>  Optional centrifugal pump for big flow and helical rotor pump for high lift.

3>  High efficient semiconductor device used in main circuit. High reliability. Up to 98% conversion efficiency  of controller.

4>  Independent intellectual property of dynamic VI maximum power point tracking (MPPT) algorithm. Fast  response  and good stability. 99% MPPT efficiency.

5>  Full automatic operation. Complete protection functions. Integrated with water level monitor to prevent

  overflow and dry running.

6>  Full aluminum alloy case. IP52 protection grade. Ambient temperature: -20~+60.

Product Specifications


3. Specification details. 

1> Flow: 0.4m³/h~22m³/h

2> Head: 10m~210m

3> Power: 0.1~3Kw

 

4. FAQ

1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?

     The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements. 

2> Does your controller have the MPPT Function?

     Yes, our controller have. This would be not a problem. 

3> Can your pump work automatically?

     Yes, it would be the basic advantage of solar water pumps. 


AC Solar Water Submersible Pump for Irrigation Purpose



AC Solar Water Submersible Pump for Irrigation Purpose




Q: How does the centrifugal pump pump and cut the pump?
Check the motor, pump and fasteners in good condition; whether the lubricant is added or not;Disc dynamic coupling, whether or not stuck phenomenon;Open the inlet valve, remove the gas in the pump or pump the gas out of the pump;
Q: What is the principle of a turbopump?
The working conditions of the turbine are different from those of the medium used, so the structure of the turbine is varied, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) mounted on a turbine shaft with blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work.
Q: The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
Q: What's the meaning of the pump head in the water pump, please advise, thank you
The pump head of the centrifugal pump refers to the shell that contains the impeller and impeller, and also includes the shaft part that drives the impeller. It can be used as the part of the motor and shaft coupling and the base.
Q: How is the pump level of submersible sewage pump determined?
Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
Q: Difference between pump and compressor
In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.The working principle of the linear pump is different from that of any other pump. It adopts the principle of magnetic suspension and the hydraulic structure of the spiral ring to realize liquid propulsion, that is, to cancel the shaft, to cancel the shaft connection, and to cancel the sealing structure of the shaft. After starting, the electric current is transformed into a magnetic field, and the magnetic field force drives the spiral ring to move, namely, the spiral ring promotes the liquid advance.Compressor (compressor), a driven fluid machine that promotes low-pressure gas as a high pressure gas, is the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle.
Q: What are the parts of a pump? How do you classify it?I just want to know
Before opening the pump suction pipes and pumps must be filled with water. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet. The outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuous outflow from the discharge pipe.Mainly by the impeller, pump shell, pump shaft, bearings and packing sealing devices and other components
Q: The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q: What is the difference between centrifugal pump and self suction pump? Which is better?
If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords