• 0.5HP QB60 Vortex Electric Swimming Pool Pump System 1
  • 0.5HP QB60 Vortex Electric Swimming Pool Pump System 2
  • 0.5HP QB60 Vortex Electric Swimming Pool Pump System 3
0.5HP QB60 Vortex Electric Swimming Pool Pump

0.5HP QB60 Vortex Electric Swimming Pool Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

          0.5HP QB60 Vortex Electric Swimming Pool Pump

1. Application of QB Series Peripheral Pumps:

1>  Clean Water without abrasive particles, non-aggressive liquid.

2>  Domestic use.

3>  In particular for delivering water in combination with small pressure sets and for irrigation.

4>  Installed in enclosed places, or at least protected against inclement weather.


2.  Operating conditions for QB Series Peripheral Pumps:

1> Suction lift up to 8m.

2> Liquid temperature up to +40℃

3> Ambient temperature up to +40℃。

4> Max. working pressure: 6bar.


3.  Motor description of QB Series Peripheral Pumps:

1> 2-pole induction motor: 50Hz.

2> Insulation: Class B.

3> Protection:  IP44.

4> With capacitor and thermal overload protection.


4.  Material of QB Series Peripheral Pumps:

1> Pump body: Cast Iron.

2> Motor bracket: Aluminum.

3> Impeller: Brass.

4> Shaft with rotor: Stainless steel or CS45#

5> Mechanical seal: Ceramic-Graphite.

6> Copper Winding.


5. Detailed specification for QB Series Peripheral Pumps:

QB Series Peripheral Pumps with Brass Impeller

6. FAQ

1). Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2). Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3). How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.




QB Series Peripheral Pumps with Brass Impeller

QB Series Peripheral Pumps with Brass Impeller


Q:Why should I pump the pump before starting the centrifugal pump?
Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.
Q:Why can't the inlet of centrifugal pump be negative pressure?
However, the centrifugal pump will have its import pressure requirements, which is to prevent cavitation, that is, the fear of the delivery of liquid at low pressure will occur gasification. Centrifugal pump has an important parameter called NPSH, for example relating to the inlet pressure, the pump NPSH, 4 meters, it means that the absolute pressure of imports should be higher than the saturated steam conveying fluid pressure of liquid column is 4 meters high, so, when it is at a temperature of saturated vapor pressure for water transport 2 meters, 4+2=6 meters minimum inlet absolute pressure. Because the absolute pressure is 10 meters water column atmospheric pressure, at this time the entrance negative pressure is 10-6 meters =4 meters water column.
Q:The distance from the pump button to the ground
Yellow warning pop-up, indicating that the fire control room has issued alarm information, fire alarm controller (commonly known as the alarm host)
Q:Suction stroke and lift of water pump
For example: there is a kind of water pump, the model is called "BSP" series, the volume is not large, but the nominal suction process can be 4 meters, it can not add water to 4 meters, it is considered to be relatively high in the micro pumpIn micro pumps, not all pumps have self-priming capacity ("suction stroke")Some centrifugal pumps there is no self-priming ability to use must first do add water. Although some micro pump with self absorption capacity, but "suction" are often the subject of "and the water inlet pipe in all air, can smoke the vertical height of water gap, even only half not so. The pump selection, the absorption process is a relatively important parameter.
Q:How to select metering pump head?
The main index affecting the selection of the pump head is the composition of the medium to be transported and added, as well as the pressure and the temperature of the external environment
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
The pump is in operation, if the over-current part of the local area (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began in the area, produce a lot of steam, forming bubbles, when the liquid contains a lot of bubbles forward by high pressure impeller zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst at the same time, the liquid particle filled hole at a high speed, this moment has a very strong effect of water hammer, and with a high impact frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be.The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
Pump flow: the volume of liquid discharged per unit time.(3) volume efficiency of pump: the ratio of actual output flow of pump to theoretical flow rate.
Q:Variable flow pumps are variable pumps
To be exact, variable pump means variable displacement. Because if the displacement does not change
Q:The working principle of magnetic pump
Working principle of magnetic pumpN of the magnet (n is even) arranged according to the laws in the magnetic clutch assembly inside and outside the magnetic rotor, the magnet part consisting of magnetic coupling system. When the inside and outside the two poles in different relative displacements, two poles between the angle phi = 0, the lowest energy magnetic system; when rotates to the relative displacement is two poles, pole angle between phi = 2 pi /n, the magnetic system of magnetic energy. Remove the external force, due to the magnetic system of magnetic poles repel each other, magnetic magnet will return to the lowest energy state. So magnets in motion, driven by the magnetic rotor.
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
1) microcomputer frequency conversion control cabinet2) water pump unit3) current stabilizing compensator4) vacuum suppressor5) all kinds of pipe fittings, valves and so on

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords