ZW Blockage-free Self Priming Centrifugal Water Pump
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 1000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Production Introduction 2. Application 4. FAQ 1. With regarding the submersible pumps, we can just get a pump head? It would be acceptable to arrange the pump head alone. All connections are conforming with the international standard. But it is also very necessary to have a confirmation before the delivery, because there are some models which is special. 2. Do you have smaller solar pump? Yes, we have. Except the solar submersible pump, we also have some surface solar pump, the voltage about it is 12V or 24V. The materials about them are plastic. 3. Can you customize the pump when we needed? This is acceptable. But we have to charge some fees in advance, because we need to make the new moulds for it sometimes. |
- Q: What are the uses and precautions of magnetic pumps?
- 5, after the motor starts, slowly open the drain valve, until the pump into the normal working state, and then discharge valve to the desired opening;6, before the pump stops working, should first close the exhaust valve, and then turn off the suction valve.
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: What are the ways of hydraulic pumps?
- Check valves, such as single piston pumps, three piston pumps, etc.;The port of the valve arrangement, such as the radial piston pump.
- Q: Water pump outlet valve sequence
- Design specifications detailed manual instructions, divided into two cases:1, pump water first check valve, suitable for small caliber pipeline, gate valve to protect the non-return valve, not damage function;2, pump water out of the first gate valve, check valve for large diameter pipe, at this point valve easy to open and close;The setting of the check valve is mainly to avoid the high reverse speed of the pump and the condition of the submerged pump house. Set in the suction port of the pump, then stop the pump water flow will still affect the pump. In addition, the pump suction should try to avoid installing too many pipe fittings, so that the pump can maintain sufficient cavitation margin.
- Q: The distance from the pump button to the ground
- A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- Should shut down the valve bar, reduce the flow to increase the point of the head, it is best to adjust within the best range of work, otherwise it is easy to cause the current is too large, burning the motor
- Q: What is the difference between centrifugal pump and positive displacement pump?
- Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;
- Q: Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
- Start the pump. Water pressure depends on how large you buy the pump, generally small, mostly 10-15 meters hydraulic pressure, about 200 of the price.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- According to your entire pipeline system to flow meter ah!How about the pressure, the material, the digital float or what?You must be sure of the size of the flow
- Q: How to calculate the motor power of metering pump?
- The total mechanical power and hydraulic power, divided by the overall efficiency of pump, and the pump head and the utilization rate of pump mechanical efficiency, and then multiplied by 1.1 times (API675), you can get a metering pump motor need more power.