Outline
Pipeline booster named Incredibles is installed in the pipeline booster pump. General said pipeline booster refers installed in pipeline transmission fluid pump means is not limited to a particular type or form of the pump, which can be vertical can also be horizontal, vertical multistage centrifugal pump as , horizontal multistage centrifugal pumps, vertical single-stage centrifugal pumps, horizontal single stage centrifugal pumps, self-priming centrifugal pumps and so can be called a pipeline booster. General industry said pipeline booster pump refers pipeline structure. Specific booster pump principle and structure, please refer to the working principle.
Features
1, most of the pipeline booster pump centrifugal pump. With a wide range of performance, manufacturing technology is mature, are more convenient to use and maintain.
2, easy to operate, reliable, easy adjustment and maintenance, and easy to implement automation and remote operation.
3, high speed, can be directly connected with electric motors and turbines, transmission mechanism is simple and compact.
4, using the pipeline structure (inlet and outlet located on the same straight line) design, installation is very simple, only needs to butt out of the outlet; maintenance such as non-pump failure, you can not remove the pipe section to the overall maintenance of the pump .
5, simple and compact structure, small size, light weight, fewer parts, ease of manufacture, low cost, and small footprint, so it's equipment and repair costs are cheaper.
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
- The elevator is mainly used by the power grid through the rectifier, filter, inverter and other transmission to the motor. The motor in high speed when the brake suddenly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power, the reverse voltage and torque original electric state torque instead, and the motor with brake strong torque, forcing the rotor to stop fast but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible and therefore cannot go back to the grid, energy will be accumulated in the filter capacitor, produce pump voltage, this phenomenon of pump voltage converter has great destructive power.
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: Water pump can not be pumped out, how to maintain water?
- Packing overheating:Due to packing too tight, the cooling water can not enter the filler, or the shaft surface damage. Measures for proper relaxation of packing and cleaning of sealing pipe are adopted. Filler wear must be replaced with new ones. Before installation, soak in the oil and rotate it in turn. The incision should be staggered so that water leakage can be reduced. Fill the last lap after installed loading pressed to cover operation for further adjustment of the tightness.
- Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
- Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
- Q: Brief description of centrifugal pump on / off operation
- First, the preparation before the start(1) carefully check the inlet and outlet pipe line, valve, flange and pressure gauge joint of the pump, whether the installation is safe, comply with the requirements, whether the flow is correct, whether the anchor bolt and other connecting parts are loose or not.(2) add lubricating oil to the bearing case, and the oil level is 2/3 of the gauge of the bearing box.
- Q: Excuse me, what is the water pump from the lotus root?
- The utility model relates to a self coupling sewage pump, which is composed of a base, a self coupling frame, a guide rod, a guide rod, a support seat, etc., and the utility model does not need bolt connection
- Q: What are the constant pressure pumps?
- Constant pressure pump is also called the booster pump, the name is used for booster pump, its main purpose is water heater booster, with tall low pressure, sauna, bath and other pressure in the apartment, the lack of water pressure, solar automatic pressurization and so on.
- Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
- Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
- Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
- The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.