Outline
Pipeline booster named Incredibles is installed in the pipeline booster pump. General said pipeline booster refers installed in pipeline transmission fluid pump means is not limited to a particular type or form of the pump, which can be vertical can also be horizontal, vertical multistage centrifugal pump as , horizontal multistage centrifugal pumps, vertical single-stage centrifugal pumps, horizontal single stage centrifugal pumps, self-priming centrifugal pumps and so can be called a pipeline booster. General industry said pipeline booster pump refers pipeline structure. Specific booster pump principle and structure, please refer to the working principle.
Features
1, most of the pipeline booster pump centrifugal pump. With a wide range of performance, manufacturing technology is mature, are more convenient to use and maintain.
2, easy to operate, reliable, easy adjustment and maintenance, and easy to implement automation and remote operation.
3, high speed, can be directly connected with electric motors and turbines, transmission mechanism is simple and compact.
4, using the pipeline structure (inlet and outlet located on the same straight line) design, installation is very simple, only needs to butt out of the outlet; maintenance such as non-pump failure, you can not remove the pipe section to the overall maintenance of the pump .
5, simple and compact structure, small size, light weight, fewer parts, ease of manufacture, low cost, and small footprint, so it's equipment and repair costs are cheaper.
- Q: Why does the centrifugal pump close the pressure to start?
- Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
- Q: What does the pump mortar do?
- In order to effectively reduce the flow resistance of concrete and pipe, to avoid obstruction caused by pipe sticking and to achieve normal pumping, and its role is generally only pumps.
- Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
- Large pump control valve controlled energy consumption at least 30% reason is that there are serious throttling loss of a throttle valve control system of severe fever but simple structure and low cost which is why now valve control system still occupy the main market reasons.Pump control system with complicated structure especially when serious nonlinear control unsymmetrical cylinder control effect is not ideal, but the biggest advantage is energy-saving and low fever America professor Monika points out that using the pump control system of hydraulic excavator energy efficiency compared with the valve control system can be improved by over 46% but costs are high. But in control, the three pump invented by Professor Quan LONG of China is a good solution. LZ can find the invention patent or find his paper on sage. It seems that there are three or four SCI about this pump
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
- Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
- Q: What is double hydraulic pump?
- [double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
- Q: The working principle of magnetic pump
- Working principle of magnetic pumpN of the magnet (n is even) arranged according to the laws in the magnetic clutch assembly inside and outside the magnetic rotor, the magnet part consisting of magnetic coupling system. When the inside and outside the two poles in different relative displacements, two poles between the angle phi = 0, the lowest energy magnetic system; when rotates to the relative displacement is two poles, pole angle between phi = 2 pi /n, the magnetic system of magnetic energy. Remove the external force, due to the magnetic system of magnetic poles repel each other, magnetic magnet will return to the lowest energy state. So magnets in motion, driven by the magnetic rotor.
- Q: What is the cause of the damage of pump bearings?
- Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
- Q: What is a vacuum pump for?
- Aquaculture, screen printing machine, photographic plate machine, injection molding machine, automatic feeding machine, paper transport...
- Q: What do you mean by the self coupling device on the pump?
- Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.