Vertical Fire Fighting Water Pump with XBD Series
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Vertical Fire Fighting Water Pump with XBD Series
1.Structure of Vertical Fire Fighting Water Pump with XBD Series Description
Portable Fire Fighting Water Pump with XBD Series is a high efficient water facility has characters of easy installation,saving space, water pool is not required.The pump energy efficient, using I mm converter speed control valve control over a large number of energy saving, the elimination of the high level of secondary pollution of water tanks,water tank eliminates the need to wash the cost and trouble,Water Pump achieve soft-start, start on the grid to reduce the impact of pumps to extend life.
2.Main Features of the Vertical Fire Fighting Water Pump with XBD Series
Water Supply: Urban water supply, boiler or condensate system, water filtering and distribution, water to water district, in charge of pressurized, high-rise building pressurization.
Industrial boosting: process water system, cleaning system, high pressure washing system, fire system.
Industrial liquid conveying: cooling and air conditioning systems, boiler feed and condensate systems, machine matching, acid and alkali.
Water Treatment: Industrial circulating system and processing system, environmental protection water treatment and infiltration analysis system, Ultrafiltration systems, reverse osmosis systems, distillation systems, separators, swimming pool
Irrigation: Agriculture irrigation and dewatering, sprinkler irrigation, drip irrigation.
3.Vertical Fire Fighting Water Pump with XBD Series images
4.Vertical Fire Fighting Water Pump with XBD Series Specification
model | capacity | pressure | speed | effeciency | power | npsh |
(L/s) | (MPa) | (r/min) | (%) | (Kw) | (NPSH)r(m) | |
XBD1.8/5-50W | 5 | 0.18 | 1450 | 65 | 2.2 | 3.2 |
XBD2.7/5-50W | 5 | 0.27 | 1450 | 65 | 3 | 3.2 |
XBD3.6/5-50W | 5 | 0.36 | 1450 | 65 | 4 | 3.2 |
XBD4.5/5-50W | 5 | 0.45 | 1450 | 65 | 5.5 | 3.2 |
XBD5.4/5-50W | 5 | 0.54 | 1450 | 65 | 5.5 | 3.2 |
XBD6.3/5-50W | 5 | 0.63 | 1450 | 65 | 7.5 | 3.2 |
XBD7.2/5-50W | 5 | 0.72 | 1450 | 65 | 7.5 | 3.2 |
XBD8.1/5-50W | 5 | 0.81 | 1450 | 65 | 7.5 | 3.2 |
XBD2.3/10-75W | 10 | 23 | 1450 | 68 | 5.5 | 3 |
XBD3.4/10-75W | 10 | 0.34 | 1450 | 68 | 7.5 | 3 |
XBD4.6/10-75W | 10 | 0.46 | 1450 | 68 | 11 | 3 |
XBD5.5/10-75W | 10 | 0.55 | 1450 | 68 | 11 | 3 |
XBD6.9/10-75W | 10 | 0.69 | 1450 | 68 | 15 | 3 |
XBD8.0/10-75W | 10 | 0.8 | 1450 | 68 | 15 | 3 |
XBD9.2/10-75W | 10 | 0.92 | 1450 | 68 | 18.5 | 3 |
XBD10.3/10-75W | 10 | 1.03 | 1450 | 68 | 18.5 | 3 |
XBD2.9/20-100W | 20 | 0.29 | 1450 | 72 | 11 | 3.5 |
XBD4.3/20-100W | 20 | 0.43 | 1450 | 72 | 15 | 3.5 |
XBD5.8/20-100W | 20 | 0.58 | 1450 | 72 | 22 | 3.5 |
XBD7.2/20-100W | 20 | 0.72 | 1450 | 72 | 30 | 3.5 |
XBD8.6/20-100W | 20 | 0.86 | 1450 | 72 | 30 | 3.5 |
XBD10.1/20-100W | 20 | 1.01 | 1450 | 72 | 37 | 3.5 |
XBD11.5/20-100W | 20 | 1.15 | 1450 | 72 | 45 | 3.5 |
XBD13.0/20-100W | 20 | 1.3 | 1450 | 72 | 45 | 3.5 |
XBD4.2/25-125W | 25 | 0.42 | 1450 | 73 | 22 | 3.5 |
XBD6.3/25-125W | 25 | 0.63 | 1450 | 73 | 30 | 3.5 |
XBD8.4/25-125W | 25 | 0.84 | 1450 | 73 | 45 | 3.5 |
XBD10.5/25-125W | 25 | 1.05 | 1450 | 73 | 55 | 3.5 |
XBD12.6/25-125W | 25 | 1.26 | 1450 | 73 | 75 | 3.5 |
XBD14.7/25-125W | 25 | 1.47 | 1450 | 73 | 75 | 3.5 |
XBD16.8/25-125W | 25 | 1.68 | 1450 | 73 | 90 | 3.5 |
XBD18.9/25-125W | 25 | 1.89 | 1450 | 73 | 90 | 3.5 |
XBD5.8/45-150W | 25 | 0.58 | 1450 | 73 | 45 | 3 |
XBD8.7/45-150W | 25 | 0.87 | 1450 | 73 | 75 | 3 |
XBD11.6/45-150W | 25 | 1.16 | 1450 | 73 | 90 | 3 |
XBD14.5/45-150W | 25 | 1.45 | 1450 | 73 | 110 | 3 |
XBD17.4/45-150W | 25 | 1.74 | 1450 | 73 | 135 | 3 |
XBD20.3/45/150W | 25 | 2.03 | 1450 | 73 | 155 | 3 |
XBD23.2/45-150W | 25 | 2.32 | 1450 | 73 | 180 | 3 |
XBD26.1/45-150W | 25 | 2.61 | 1450 | 73 | 180 | 3 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: What's the pump? Where can I use it?
- Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
- Q: Why can't the inlet of centrifugal pump be negative pressure?
- The entrance can be a negative pressure. You can often see someone pumping water from the pool. How can you pump water if it is not negative pressure?
- Q: Is the sewage pump the same as the mud pump?
- Sewage pump is mainly used for industrial wastewater treatment, sewage treatment, environmental protection has played a big role. Among them, the sewage pump is also a sewage pump with cutting wheel, such sewage pump can be chopped dirt, and then extract the sewage clean.
- Q: How high can the pneumatic diaphragm pump be?
- Pump made of polyvinylidene fluoride (PVDF) material two, the series of pneumatic diaphragm pump belongs to the fluorine plastic pneumatic diaphragm pump is also known as the corrosion products of pneumatic diaphragm pump, diaphragm liquid contact using PTFE material, using PVDF material produced by pneumatic diaphragm pump is mainly used in corrosive the pH, mainly used for chemical liquid conveying multiple solvent, corrosion resistance effect is very good. The series of fluorine plastic pneumatic diaphragm pump in high temperature less than 93.3 degrees.POM pump material also has good resistance to solvent and abrasion resistance, low friction resistance, moisture absorption is also low, the highest temperature of such pumps within 65.5 degreesPolytetrafluoroethylene (PTFE) membrane corrosion resistance is very good, in addition to liquid metal lithium, potassium fluoride, sodium fluoride, three chlorine, three fluoride high temperature oxygen, high flow rate, almost all of the chemical liquid transport (including concentrated nitric acid and aqua regia), PTFE material the maximum temperature to 176.6 degrees. However, for the diaphragm pump product as the diaphragm moves back and forth in work, we suggest that at a temperature of 120 degrees, the prerequisite is the pump body pump must be made of metal material and plastic material. The pump is the pump of PVDF material temperature is highest in less than 93.3 degrees.
- Q: What are the main performance parameters of hydraulic pumps?
- Main performance parameters of hydraulic pump:1. Hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Specification for concrete cylinders:Bore * stroke mm 200 * 1650Hopper capacity L 800Feeding height mm 1400Motor model Y2-280M-4Power kw 90Rated voltage V 380Rated speed r/min 1480Soft starter withoutHydraulic system open-loop
- Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
- Have to know the ratio, pneumatic pump, if high pressure, you can have 2:1,3:1
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- First of all, we know that pump according to the principle of work is divided into speed and volume type, centrifugal pumps are speed type, and reciprocating pumps are volume type.The centrifugal pump can adjust the flow through the outlet valve and outlet valve opening can determine the pump flow and head performance curve parameters such as specific relationship between the outlet flow and pressure can be provided by the data pump manufacturers endplate that even close the outlet valve of the pump pressure will also have a fixed value, but not allow zero flow pump operation, vibration caused by damage to the pump on the mechanical seal is not good and so easy to cavitation, set the minimum reflux line.
- Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
- The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
- Q: What is the distance between the pump and the wall?
- What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Send your message to us
Vertical Fire Fighting Water Pump with XBD Series
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches