1.Structure of Vertical Fire Fighting Water Pump with XBD Series Description
Portable Fire Fighting Water Pump with XBD Series is a high efficient water facility has characters of easy installation,saving space, water pool is not required.The pump energy efficient, using I mm converter speed control valve control over a large number of energy saving, the elimination of the high level of secondary pollution of water tanks,water tank eliminates the need to wash the cost and trouble,Water Pump achieve soft-start, start on the grid to reduce the impact of pumps to extend life.
2.Main Features of the Vertical Fire Fighting Water Pump with XBD Series
Water Supply: Urban water supply, boiler or condensate system, water filtering and distribution, water to water district, in charge of pressurized, high-rise building pressurization.
Industrial boosting: process water system, cleaning system, high pressure washing system, fire system.
Industrial liquid conveying: cooling and air conditioning systems, boiler feed and condensate systems, machine matching, acid and alkali.
Water Treatment: Industrial circulating system and processing system, environmental protection water treatment and infiltration analysis system, Ultrafiltration systems, reverse osmosis systems, distillation systems, separators, swimming pool
Irrigation: Agriculture irrigation and dewatering, sprinkler irrigation, drip irrigation.
3.Vertical Fire Fighting Water Pump with XBD Series images
4.Vertical Fire Fighting Water Pump with XBD Series Specification
model | capacity | pressure | speed | effeciency | power | npsh |
(L/s) | (MPa) | (r/min) | (%) | (Kw) | (NPSH)r(m) | |
XBD1.8/5-50W | 5 | 0.18 | 1450 | 65 | 2.2 | 3.2 |
XBD2.7/5-50W | 5 | 0.27 | 1450 | 65 | 3 | 3.2 |
XBD3.6/5-50W | 5 | 0.36 | 1450 | 65 | 4 | 3.2 |
XBD4.5/5-50W | 5 | 0.45 | 1450 | 65 | 5.5 | 3.2 |
XBD5.4/5-50W | 5 | 0.54 | 1450 | 65 | 5.5 | 3.2 |
XBD6.3/5-50W | 5 | 0.63 | 1450 | 65 | 7.5 | 3.2 |
XBD7.2/5-50W | 5 | 0.72 | 1450 | 65 | 7.5 | 3.2 |
XBD8.1/5-50W | 5 | 0.81 | 1450 | 65 | 7.5 | 3.2 |
XBD2.3/10-75W | 10 | 23 | 1450 | 68 | 5.5 | 3 |
XBD3.4/10-75W | 10 | 0.34 | 1450 | 68 | 7.5 | 3 |
XBD4.6/10-75W | 10 | 0.46 | 1450 | 68 | 11 | 3 |
XBD5.5/10-75W | 10 | 0.55 | 1450 | 68 | 11 | 3 |
XBD6.9/10-75W | 10 | 0.69 | 1450 | 68 | 15 | 3 |
XBD8.0/10-75W | 10 | 0.8 | 1450 | 68 | 15 | 3 |
XBD9.2/10-75W | 10 | 0.92 | 1450 | 68 | 18.5 | 3 |
XBD10.3/10-75W | 10 | 1.03 | 1450 | 68 | 18.5 | 3 |
XBD2.9/20-100W | 20 | 0.29 | 1450 | 72 | 11 | 3.5 |
XBD4.3/20-100W | 20 | 0.43 | 1450 | 72 | 15 | 3.5 |
XBD5.8/20-100W | 20 | 0.58 | 1450 | 72 | 22 | 3.5 |
XBD7.2/20-100W | 20 | 0.72 | 1450 | 72 | 30 | 3.5 |
XBD8.6/20-100W | 20 | 0.86 | 1450 | 72 | 30 | 3.5 |
XBD10.1/20-100W | 20 | 1.01 | 1450 | 72 | 37 | 3.5 |
XBD11.5/20-100W | 20 | 1.15 | 1450 | 72 | 45 | 3.5 |
XBD13.0/20-100W | 20 | 1.3 | 1450 | 72 | 45 | 3.5 |
XBD4.2/25-125W | 25 | 0.42 | 1450 | 73 | 22 | 3.5 |
XBD6.3/25-125W | 25 | 0.63 | 1450 | 73 | 30 | 3.5 |
XBD8.4/25-125W | 25 | 0.84 | 1450 | 73 | 45 | 3.5 |
XBD10.5/25-125W | 25 | 1.05 | 1450 | 73 | 55 | 3.5 |
XBD12.6/25-125W | 25 | 1.26 | 1450 | 73 | 75 | 3.5 |
XBD14.7/25-125W | 25 | 1.47 | 1450 | 73 | 75 | 3.5 |
XBD16.8/25-125W | 25 | 1.68 | 1450 | 73 | 90 | 3.5 |
XBD18.9/25-125W | 25 | 1.89 | 1450 | 73 | 90 | 3.5 |
XBD5.8/45-150W | 25 | 0.58 | 1450 | 73 | 45 | 3 |
XBD8.7/45-150W | 25 | 0.87 | 1450 | 73 | 75 | 3 |
XBD11.6/45-150W | 25 | 1.16 | 1450 | 73 | 90 | 3 |
XBD14.5/45-150W | 25 | 1.45 | 1450 | 73 | 110 | 3 |
XBD17.4/45-150W | 25 | 1.74 | 1450 | 73 | 135 | 3 |
XBD20.3/45/150W | 25 | 2.03 | 1450 | 73 | 155 | 3 |
XBD23.2/45-150W | 25 | 2.32 | 1450 | 73 | 180 | 3 |
XBD26.1/45-150W | 25 | 2.61 | 1450 | 73 | 180 | 3 |
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also
provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.
- Q: Fire pump and shower pump flow head selection, high resolution.
- 3, larger than 25000, the minimum water consumption of indoor fire hydrant is 20L/s4, the minimum water consumption is the flow of a fire hydrant.
- Q: Must the water pump in the tank be all soaked in water?
- Need a submersible pump in the water, but it is not entirely like this, I have to work for a long time no problem in water, but there is a problem you should pay attention to the water pump, at least in half, or stop when the smoke is not on water.
- Q: What are the characteristics of a pipe shield pump?
- According to the transmission of liquid temperature, pressure, viscosity and particle level have different requirements, the pump can be divided into the following types: first, the basic type (standard type) transport medium temperature does not exceed 120 degrees, the head of not more than 100m, the pump other types are variations on the basic type and improved.
- Q: What are the reasons for sealing damage of centrifugal pumps?
- Three, water shortages caused by running dry grinding damage.This phenomenon is more common in mounted form inlet pressure, inlet air, air cavity pump, pump boot, high temperature operation of the mechanical seal friction at high speed, can not be cooled, check the mechanical seal, the spring tension is normal, the friction surface of charred black, rubber hard cracking.Treatment methods: exhaust the pipe and pump cavity air, replace the machine seal.Four, install too tight, observe the mechanical seal of dynamic and static ring plane, if there is serious burning phenomenon, flat black and deep traces, sealing rubber hardens, lose elasticity.This phenomenon is due to tight installation.Treatment methods: adjust the installation height, impeller installed, with a screwdriver to move the spring, the spring has a strong tension, release after the reset, there is 2-4mm moving distance can.
- Q: Excuse me, what is the water pump from the lotus root?
- Submersible sewage pump with septic tank, outlet pipe automatic coupling installation, dipping down can be.
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- Direct connected pump: pump impeller installed directly on the motor shaft, it looks like a whole, relatively compact, simple installation, but the general power is relatively small (big bad processing connection, but not absolute);Non direct pump: pumps and motors are independent of each other, through the coupling torque transmission, the structure is relatively large, complex installation, to adjust the level / concentricity and so on, the general power is relatively large
- Q: Hydraulic pump displacement refers to the pump shaft what?
- You can see the sign of your hydraulic pump. There will be a displacement **ml/r in the sign of the hydraulic pump (r stands for every turn, ML is milliliter)
- Q: Common failure treatment of piston pump
- Table 15 common troubles and treatment of hydraulic pumpsFault phenomenon, x09 cause analysis, x09 elimination method(1) the pump does not carry oil; the x091. pump does not turn x09 (1); the motor shaft does not rotate1) missed connection power supply2) electrical wiring and component failure, x09 check electrical and troubleshootx09x09 (2) motor heating trip
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- Day pump: the pump and pipe will be placed in a position on the site, the pipe in the air like the crane arm
- Q: Metering pumps related matters
- Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.