Variable Frequency Converter 50HZ 60HZ 220v to 380v Inverter 4KW 5.5KW 7.5KW 11KW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Variable speed drive
1), Super quality, competitive price, good after-sale service
2), universal motor speed control
3) VFD
VFD AC frequency converter Inverter 50HZ 60HZ 220v to 380v AC motor Drive
Product Description
PI9000 series inverters are high performance open loop vector inverter for controlling asynchronous AC induction motors andpermanent magnet synchronous motors.
PI9000 Specification
Item | Specification | |
Control | Voltage and frequency levels | Single-phase 220,50/60Hz Three-phase 220V,50/60Hz |
Three-phase 480V,50/60Hz 380,50/60Hz | ||
Three-phase 690V,50/60Hz | ||
Allowable fluctuation | Voltage:±10% Frequency:±5% | |
Control system | High performance vector control inverter based on DSP | |
Output frequency | Vector control:0 to 300Hz V/F control:0 to 600Hz | |
Control method | V/F control, vector control W/O PG, vector control W/ PG | |
Automatic torque boost function | Realize low frequency (1Hz) and large output torque control under the V/F control mode. | |
Acceleration/deceleration control | Straight or S-curve mode. Four times available and time range is 0.0 to 6500.0s. | |
V/F curve mode | Linear,square root/m-th power,custom V/F curve | |
Over load capability | G type:rated current 150% - 1 minute, rated current 180% - 2 seconds | |
F type:rated current 120% - 1 minute, rated current 150% - 2 seconds | ||
Maximum frequency | Vector control:0 to 300Hz V/F control:0 to 600Hz | |
Carrier Frequency | 0.5 to 15kHZ;automatically adjust carrier frequency according to the load characteristics. | |
Input frequency resolution | Digital setting: 0.01Hz Analog setting: maximum frequency×0.025% | |
Start torque | G type: 0.5Hz/150% (vector control W/O PG) F type: 0.5Hz/100% (vector control W/O PG) | |
Speed range | 1:100 (vector control W/O PG) 1:1000 (vector control W/ PG) | |
Steady-speed precision | Vector control W/O PG: ≤ ± 0.5% (rated synchronous speed) | |
Vector control W/ PG: ≤ ± 0.02% (rated synchronous speed) | ||
Speed control accuracy | Vector control W/O PG≤±0.3% ( rated synchronous speed ) | |
Torque response | ≤ 40ms (vector control W/O PG) | |
Torque boost | Automatic torque boost; manual torque boost(0.1% to 30.0%) | |
DC braking | DC braking frequency: 0.0Hz to max. frequency, braking time: | |
Jogging control | Jog Frequency Range: 0.00Hz to max. frequency; | |
Multi-speed operation | Achieve up to 16-speed operation through the control terminal | |
Built-in PID | Easy to realize closed-loop control system for the process control. | |
Automatic voltage regulation(AVR) | Automatically maintain a constant output voltage when the voltage of electricity grid changes | |
Torque limit and control | "Excavator" feature - torque is automatically limited during the operation to prevent frequent | |
Running method | Keyboard/terminal/communication | |
Communication | RS485/RS232/CANBUS/PROFIBUS | The optional completely isolated RS485/RS232/CANBUS/PROFIBUS communication module can communicate with the host computer. |
Product standard | Product adopts safety standards. | IEC61800-5-1:2007 |
Product adopts EMC standards. | IEC61800-3:2005 | |
Cooling method | Forced air cooling and natural air cooling |
FAQ
Why do most clients choose PI9000?
1,150% torque at 0.5hz;
2,Vector control with open-loop,closed-loop control;
3,Automatically identify the motor parameters,self-learning;
4,install PID,main spindle control for CNC lathe;
5, Modbus communication protocol,RS485 communication,CANlink;
6, Simple PLC and multistage speed;
7,Speed tracking function;
8,Carrier frequency automatic adjustment;
9,Pendulum frequency;
10,Various protection mechanisms (over current/over voltage/overload, overheating, etc),
to protect the inverter and motor.
- Q: What is the number of parameters of the motor frequency of the Siemens inverter?
- It is best to provide the model of the inverter Oh!
- Q: Does the teacher know the working principle of the inverter?
- The frequency converter is an AC-DC-AC power electronic device that converts 50 Hz AC sine wave into straight high voltage direct current and then converts it into an AC power that can control the voltage and frequency, driving the three-phase AC motor.
- Q: What is the laptop adapter
- 3, classification: according to the use of points (AC, such as home, office use AC are called AC; DC, such as the car, the aircraft are used DC are called DC); by the output voltage current (12V series, ASUS more commonly used, such as ASUS 12V3A; 15V series, TOSHIBA more commonly used, such as TOSHIBA 15V3A, 15V4A, 15V5A; 16V series, SONY, IBM more commonly used, such as SONY 16V4A, IBM 16V4.5A; Series, HP, such as HP 18.5V3.5A; 19V series, such as ACER 19V3.42A, TOSHIBA 19V3.42A; 19.5V series, such as DELL 19.5V3.34A, SONY 19.5V4.1A; 20V series, such as DELL 203.5A , LENOVO 20V3.25A; 24V series, such as APPLE 24V1.875A; 9.5V-24V series, such as Acharger ALS-185A35C).
- Q: Laptop power adapter leakage
- In fact, the adapter does not matter fake real goods, brand machine adapter are also purchased. According to my point of view, or I choose the words: casually buy one can, dozens of dollars on the line. In fact, the adapter is also worth tens of dollars, selling a few hundred dollars are also almost the same thing. Adapter is a small switching power supply, 100W or so, the value of that price.
- Q: Will the motor suddenly stop when the inverter is suddenly powered down?
- Generally in the absence of external brake or brake case, if the power, the motor is in a free stop state, uncontrolled,will gradually slow down to 0
- Q: My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
- Motor current when the current 10A this has no effect on you, the rated current is 31.4A, your inverter is selected how many W, is the fan pump type or universal? Now the motor operating current reached 34-35A, more than the rated current, then the motor may have two problems, one is the motor leakage powerful, and in a motor is overload, resulting in increased current
- Q: The inverter is running independently
- . Main working circuit (1) Operation circuit: the external speed, torque and other instructions with the detection circuit current and voltage signal comparison operation, determine the inverter output voltage, frequency. (2) voltage and current detection circuit: isolation with the main circuit potential detection voltage, current and so on. (3) drive circuit: drive the main circuit device circuit. It is isolated from the control circuit to turn on and off the main circuit device. (4) speed detection circuit: mounted on the asynchronous motor shaft speed detector (tg, plg, etc.) signal for the speed signal into the operation loop, according to the command and operation can make the motor running at the command speed. (5) protection circuit: the detection of the main circuit voltage, current, etc., when the overload or over-voltage and other abnormalities, in order to prevent the inverter and asynchronous motor damage
- Q: What is the frequency converter used to do, why some motor with the inverter?
- Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply and other fields. The motor is equipped with the frequency converter.
- Q: Siemens g120 inverter torque limit what is the meaning
- Torque is a strain, the inverter can not actively control the output torque size, only according to the size of the load demand torque, the output of the corresponding torque.
- Q: Quartet of the TA, TC terminals have positive and negative?
- This can not be said to be positive and negative, should be called the public, TA, is the common.
Send your message to us
Variable Frequency Converter 50HZ 60HZ 220v to 380v Inverter 4KW 5.5KW 7.5KW 11KW
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords