380v Frequency inverter 50Hz to 60Hz for three phase motors 380V 245kw inverter :
AMK3500 Magnetic flux vector control AC Drive:0.75kW--2.2kW
AMK3800 Current vector inverter:4kW--630kW
Voltage:Low voltage 380v
Size:Width: 790mm Height: 1172mm Thickness:397mm
Performance characteristics:
1,This inverter can automatic energy-saving operation; Aimike inverter can increase the rate of power saving utmost.
2,This inverter can maximum limit keep voltage stability.
3, This inverter can be tested to automatic over-current and over-voltage protection; Aimike inverter can protect customers utmost equipment and frequency converter.
4, This inverter can automatically detect the load function.
5, This inverter has the advanced current closed-loop vector control algorithm; Aimike load response of the inverter can be quickly, to get the best output performance.
6, This inverter has the unique adaptive control technology, and unique pulse width modulation technology; Aimike inverter can make optimal control performance.
7,Use the SVPWM optimized modulation technology to improve product stability and longevity.
8, This inverter adopts flexible control method, such as RS - 485 control, PI regulation, multistage speed, process control, etc.
- Q: Laptop power adapter current is not the same alternative?
- so the output voltage, the same output polarity, the output current of the adapter can be used in smaller power notebook, and small power adapter can not be used to give Powerful notebooks,
- Q: Is it possible to use a different laptop's power adapter?
- For the power adapter, whether access to equipment, the following aspects of the measurement standards: Interface form The interface plug and socket used must be dimensioned. Voltage size The output voltage of the adapter is the same as the required voltage of the connected device (eg notebook). Inconsistencies may not be able to start or burn the device properly. Current or power The power of the adapter is greater than the maximum power required by the device. Power is not enough, may cause the voltage to drop, the adapter is hot, or burn the adapter. More than the above, the use of more power of the power adapter, while meeting the interface and voltage conditions, it can be replaced.
- Q: The relationship between the power supply of the notebook and the battery
- The relationship between the laptop power adapter and the battery should not be called a power supply relationship, both of which are devices that power the notebook host. The basic relationship between the power adapter, the battery, and the host is as follows:
- Q: The inverter is running independently
- . Main working circuit (1) Operation circuit: the external speed, torque and other instructions with the detection circuit current and voltage signal comparison operation, determine the inverter output voltage, frequency. (2) voltage and current detection circuit: isolation with the main circuit potential detection voltage, current and so on. (3) drive circuit: drive the main circuit device circuit. It is isolated from the control circuit to turn on and off the main circuit device. (4) speed detection circuit: mounted on the asynchronous motor shaft speed detector (tg, plg, etc.) signal for the speed signal into the operation loop, according to the command and operation can make the motor running at the command speed. (5) protection circuit: the detection of the main circuit voltage, current, etc., when the overload or over-voltage and other abnormalities, in order to prevent the inverter and asynchronous motor damage
- Q: My laptop can not use the power adapter, and can only use the battery, how is it ah,
- I have encountered the same problem, plug in the adapter, or use the battery power, the battery alarm, not the battery charge, the power adapter can not be used. But the power can charge the battery. If the power adapter alone, one will automatically shut down. Measure the adapter voltage normally. And then to get the computer city maintenance department, gymnastics, it is a simple question, the original power line in the circuit board on the solder joints are loose, that is, Weld, resulting in insufficient current, no wonder, off the machine can charge, boot can not charge, It shuts down. Spent 100 yuan. Business really black. I saw the repair. On the welding a few times OK. No wonder, once I suddenly shot about, the adapter can be used. Later, how to shoot not work. However, although spent 100, but my computer's heat silicone grease for the whole, the computer CPU temperature is not so high before. The beginning of the maintenance staff said that the power management chip may be broken, if the bad to more than 100, then, no bad, just contact the problem, welding also received me 100, really depressed. In fact, you can say good, if the contact problem, certainly below 100.
- Q: What is the frequency of `30 points
- AC are frequency, China is 50 Hz, is in a second amplitude of 50 times. To change this frequency, it is necessary to use some electronic components to change the current frequency. General frequency conversion for the tributary motor speed more. So that some equipment can be stepless. Principle, see the first floor just fine, copy the more detailed.
- Q: Yasukawa inverter reported bb code that is the reason why the base blockade?
- This should be the meaning of the drive block, that is, the drive signal is locked, there is no drive signal, and start a frequency change but no voltage output, you find someone to repair the circuit board can be used normally, this is generally the circuit board Problem, the module is less likely to be bad
- Q: Fuji inverter motor set the number of poles will not have any effect?
- The number of motor poles corresponds to the speed of the motor, the number of poles is not set when the speed of the control error, in the high speed requirements of the transmission is not allowed.
- Q: Taian inverter 3.7KW 380V with 4.0KW 2 pole motor 18000 to 300HZ can it?
- Second, is the higher speed, parking, inertia, the motor into a generator, to the module reverse power supply, resulting in the module burned, this time, should consider adding braking resistor and braking unit.
- Q: What is the IGBT? Our inverter IGBT fried,
- Popular point is a switch, give him the signal to continue in accordance with a certain order switch, the DC through the switch into a change in the exchange of alternating current, different frequency.