Small Vertical centrifugal Sewage Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Production Introduction:
WQ blockage-free sewage submersible pump(hereinafter as pump) is untegrative motor and pump. Which is manufactured based on absorbing domestic and foreignadvanced technology and advantages. Impeller, designed with hydraulic model and made by precision casting, has the advantages of energy-saving, anti-winding and non-clogging,etc. At the same time, the pumps have a unique effect in the carriage of solid particles and long fibers garbage. Single or dual impeller structure ensures the pump has the higher efficiency when it has bigger flow. So this king of pump is a ideal drainage pumps for industries and cities.
Application:
1. Living waste water discharging
2.Sewage system of municipal works
3.Sewage system in factory and mine corporation
4.Other transportation of none orrosive and diluted medium
5.Temporary floodwater discharging
6.Waste water discharging of public facility
7.Various waterd is chharging system
Work Conditions:
1.Capacity scope:2-1500m³h;
2.System pressure:≤0.6mpa;
3.Medium consistency:≤1.3x10³kg/m³
4.Motor insulation class:IP68;
5.Rotation:clockwise rotation viewed from motor;
6.Rated Speed:970-2900r/min;
7.Head scope: 3-45;
8.Medium temperature:-15℃-+60℃;
9.Medium PH scope:5-9;
10.Motor insulation class:E Grode;
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q: What are the general water pump failure, how to repair?
- (4) because of the long latent water and the corrosion of the pipe wall, the water inlet of the water inlet is constantly dropping. When the holes appear above the water, the air enters the water inlet pipe from the hole.(5) there is a crack at the bend of the inlet pipe, and there is a small gap between the inlet pipe and the water pump, which may cause the air to enter the inlet pipe.
- Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
- [pump voltage] when braking, in the motor winding series resistance, motor equivalent to the generator, the energy will be converted to electric energy consumption in the series resistance. This method is widely used in all kinds of motor braking, and frequency conversion control is also used. From high to low (zero speed), then the electrical frequency changes quickly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power,
- Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,
- Q: What's the meaning of the pump head in the water pump, please advise, thank you
- The pump head of the centrifugal pump refers to the shell that contains the impeller and impeller, and also includes the shaft part that drives the impeller. It can be used as the part of the motor and shaft coupling and the base.
- Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
- The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
- Q: What's the word "pump"? Is that what advocates mean?RT
- Is generally believed that the "wholesale" is the "hoarding" of "hoarding" variant, can be used to replace the word "store". And "wholesale" compared to "store" is clearly better and better recognize, because the "store" is a phonogram, hoard shaped characters "mouth", said the biggest the range of aggregation, like a grain bin; "Tun" is also phonetic, semantic. Tun, originally refers to the grass speared out of shape, with curly tails, and gathered the meaning.In this case, the "fans" can be written as "Yong Tun". But this is also troublesome, because the "store" in addition to read "Tun" (Ping Sheng), another pronunciation of "Dun" (Qu Sheng), who said food utensils, when we had the "Valley" store. So, if the "fans" to "hold", is also wrong. "Bin Zhao Wei fans" although it sounds strange, but at least not ambiguous; if changed to "Zhao Wei", is that we have to hoard may hear "Zhao Wei" or "Zhao Wei hold hip", hold the shield this is not the more the more chaotic change it!It is suggested that the "fans" to "fantastic", the modified method was acceptable. In modern Chinese, "public" does not necessarily mean that many, can also refer to a single. "One of the masses", "one of the audience (or audience)" this kind of argument, has been about good. Since this kind, we say "a fantastic" what not? "Fantastic" at least than the "fans" straightaway. The problem is, the word and Hong Kong Standards, there is no "fantastic".
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- Centrifugal pump, and is a very common method of centrifugal pump, flow with the head (or pressure) increases, off a small valve resistance increases, the pump head should be increased, then the flow decreased, whereas open valve flow increase
- Q: What's the difference between a concrete pump and a concrete pump truck?
- Concrete pump is a pumping machine used in the field, while the concrete pump truck is a truck mounted pump.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- The pressure decreases, the diaphragm moves slowly, and the flow decreases.This is not particularly accurate, because the diaphragm is not a metering pump, but the approximate flow can still be controlled.
Send your message to us
Small Vertical centrifugal Sewage Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches