1.Structure of Sea Water Lift Pump with Automatic Coupler Description

 

Sea Water Lift Pump with Automatic Coupler of sewage basic dormant,along with sewage pumping,sewage things gradually deposition in the bottom of the pool. But the sediment could not force with sewage went out at the pumps normal operation of inlet water alone.So the deposit is more and more at bottom of pool,which eventually led to affect normal work of pump.Engineering clean the sewage pool regularly ,so as to avoid waste of human and material resources.We produce this kind of sewagepumps,which is mounted mixing impeller at the the bottom of pumps,along with the rotation of pump, driving the impeller highspeed mixing.Thus, stir up the deposit  of bottom, mix with water, and flow out with water.Also can match with coupler,make more quick and convenient installation and maintenance.

 

2.Main Features of the Sea Water Lift Pump with Automatic Coupler

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

•Parallel connection and have many models to be chosen for difference flow rate and head

•Horizontally and vertically installation as different pipeline system

3.Sea Water Lift Pump with Automatic Coupler images

Sea Water Lift Pump with Automatic Coupler with WQ Series

4.Sea Water Lift Pump with Automatic Coupler Specification

 

ModelCapacityHeadSpeedEfficiencyPowerOutlet
Q(m3/h)H (m)n(rpm)η (%)Kwmm
40WQ-12-15-1.51215290048%1.540
50WQ-10-10-0.751010290054%0.7550
50WQ-15-15-1.51515290051%1.550
50WQ-15-20-2.21520290051%2.250
50WQ-17-25-31725290053%350
50WQ-20-7-0.75207290062%0.7550
50WQ-22-20-42220290069%450
50WQ-25-10-1.52510290067%1.550
50WQ-25-32-5.52532290049%5.550
50WQ-40-15-44015290076%450
50WQ-40-30-7.54030290062%7.550
65WQ-25-15-2.22515290052%2.265
65WQ-25-28-42528290058%465
65WQ-37-13-33713290060%365
80WQ-29-9-2.2299290048%2.280
80WQ-40-7-2.2407290050%2.280
80WQ-40-15-44015290057%480
80WQ-43-13-34313290065%380
80WQ-50-10-35010290072%380
80WQ-50-25-7.55025290056%7.580
100WQ-50-22-7.55022145063%7.5100
100WQ-50-35-115035145062%11100
100WQ-65-15-5.56515145059%5.5100
100WQ-70-7-3707145075%3100
100WQ-70-22-117022145070%11100
100WQ-80-9-4809145062%4100
100WQ-80-20-7.58020145071%7.5100
100WQ-100-7-41007145075%4100
100WQ-100-15-7.510015145070%7.5100
100WQ-100-22-1510022145061%15100
100WQ-110-10-5.511010145067%5.5100
100WQ-110-15-7.511015145075%7.5100
150WQ-130-30-2213030145069%22150
150WQ-140-7-5.51407145079%5.5150

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: Why should the pump be closed when the centrifugal pump is started?
Therefore to close the outlet valve, the pump during starting output water, the minimum pump power, when the pump reaches the rated speed, slowly open the outlet valve, gradually increase the flow of water, the motor current is gradually increased to the rated current.
Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q: There are second cutting, third cutting, why three times?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q: Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,
Q: The main factors affecting the performance of centrifugal pumps
Revolutions required to have. It has the following meanings: 1, similar to the geometry of centrifugal pump, everywhere efficiency at the top of the similar condition; centrifugal pump 2, than the number of different, its geometry must be different than the number; the same pump, its shape is similar, but does not rule out the shape similar situation. The following factors are related to specific speed. The specific speed of centrifugal pump has nothing to do with the nature of the conveying fluid, but has a close relationship with the shape of the impeller and the performance curve of the pump. The pump with high specific speed corresponds to the highest efficiency when the flow rate is large and the head is small
Q: Is the sewage pump the same as the mud pump?
Two of the main performance parameters of mud displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement. The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.Sewage pump is mainly used for industrial wastewater treatment, sewage treatment, environmental protection has played a big role. Among them, the sewage pump is also a sewage pump with cutting wheel, such sewage pump can be chopped dirt, and then extract the sewage clean.
Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q: Working principle and structure of external gear pump
External gear pump is the most widely used gear pump, the general gear pump usually refers to the external gear pump. Its structure as shown in the diagram, there are mainly driving gear, driven gear, pump body, pump cover and safety valve and so on. The seal space of pump body, pump cover and gear is the workshop of gear pump. The wheel shafts of the two gears are respectively arranged in the bearing holes on the two pump cover, and the driving gear shaft extends out of the pump body and is driven by the motor to rotate. The external gear pump is simple in structure, light in weight, low in cost, reliable in operation and wide in application. When the gear pump works, the driving wheel rotates with the motor and drives the driven wheel to rotate