• Rated Voltage 600V PVC Insulated Nylon-jacket Wire and Cable System 1
  • Rated Voltage 600V PVC Insulated Nylon-jacket Wire and Cable System 2
Rated Voltage 600V PVC Insulated Nylon-jacket Wire and Cable

Rated Voltage 600V PVC Insulated Nylon-jacket Wire and Cable

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Applications

PVC insulated nylon sheathed wire is according to UL62, UL83, UL1581 standard and the design and manufacture. Nylon sheathed line main model have: THHN, THWN, 80 ℃ and 105 ℃ and heat resistance level.

Nylon sheathed wire is more excellent electrical and physical properties, good heat resistance, can slow or reduce the PVC components has escaped or migration. Nylon sheathed line with protection against corrosion and self lubrication and oil resistance characteristics, and the same specification PVC insulated wire with diameter than it small, light weight, small static friction coefficient and anti-corrosion, can improve the safety in laying and suitability.


AWG

Conductors Construction

n/mm

Conductor

Outer diameter

mm

PVC Insulation

Min Average Thickness mm

 

PVC Insulation

Reference outer diameter

mm

Nylon-jacketMin Average Thickness mm

Wire reference

Outer diameter

mm

Maximum DC resistance at 20 ℃Ω/km

22

1/0.643

0.64

0.38

1.46

0.10

1.66

54.3

22

7/0.254

0.76

0.38

1.58

0.10

1.78

54.3

22

11/0.200

0.77

0.38

1.59

0.10

1.79

54.3

22

17/0.160

0.76

0.38

1.58

0.10

1.78

54.3

21

1/0.724

0.72

0.38

1.54

0.10

1.74

42.7

21

17/0.178

0.85

0.38

1.67

0.10

1.87

42.7

21

21/0.160

0.85

0.38

1.67

0.10

1.87

42.7

20

1/0.813

0.81

0.38

1.63

0.10

1.83

33.9

20

7/0.310

0.93

0.38

1.75

0.10

1.95

33.9

20

21/0.180

0.95

0.38

1.77

0.10

1.97

33.9

20

26/0.160

0.94

0.38

1.76

0.10

1.96

33.9

18

1/1.020

1.02

0.38

1.84

0.10

2.04

21.4

18

7/0.390

1.17

0.38

1.99

0.10

2.19

21.4

18

16/0.254

1.17

0.38

1.99

0.10

2.19

21.4

18

34/0.180

1.21

0.38

2.03

0.10

2.23

21.4

18

41/0.160

1.18

0.38

2.00

0.10

2.20

21.4

16

1/1.300

1.30

0.38

2.12

0.10

2.32

13.5

16

7/0.500

1.50

0.38

2.32

0.10

2.52

13.5

16

19/0.300

1.50

0.38

2.32

0.10

2.52

13.5

16

26/0.254

1.49

0.38

2.31

0.10

2.51

13.5

16

65/0.160

1.49

0.38

2.31

0.10

2.51

13.5

14

1/1.630

1.63

0.38

2.45

0.10

2.65

8.45

14

7/0.620

1.86

0.38

2.68

0.10

2.88

8.45

14

19/0.373

1.87

0.38

2.69

0.10

2.89

8.45

14

41/0.254

1.88

0.38

2.70

0.10

2.90

8.45

14

105/0.160

2.15

0.38

2.97

0.10

3.17

8.45

12

1/2.060

2.06

0.38

2.88

0.10

3.08

5.31

12

7/0.810

2.43

0.38

3.25

0.10

3.45

5.31

12

19/0.480

2.40

0.38

3.22

0.10

3.42

5.31

12

65/0.254

2.36

0.38

3.18

0.10

3.38

5.31

10

1/2.588

2.59

0.51

3.69

0.13

3.95

3.36

10

7/0.980

2.94

0.51

4.04

0.13

4.30

3.36

10

19/0.595

2.98

0.51

4.08

0.13

4.34

3.36

10

49/0.370

2.99

0.51

4.09

0.13

4.35

3.36

10

105/0.254

3.41

0.51

4.51

0.13

4.77

3.36

8

1/3.270

3.27

0.76

4.85

0.13

5.11

2.11

8

7/1.250

3.75

0.76

5.33

0.13

5.59

2.11

8

19/0.750

3.75

0.76

5.33

0.13

5.59

2.11

8

78/0.370

4.28

0.76

5.86

0.13

6.12

2.11

8

168/0.254

4.31

0.76

5.89

0.13

6.15

2.11

6

7/1.630

4.89

0.76

6.47

0.13

6.73

1.33

6

19/0.950

4.75

0.76

6.33

0.13

6.59

1.33

6

66/0.511

5.43

0.76

7.01

0.13

7.27

1.33

6

105/0.404

5.42

0.76

7.00

0.13

7.26

1.33

6

126/0.370

5.43

0.76

7.01

0.13

7.27

1.33

6

266/0.254

5.48

0.76

7.06

0.13

7.32

1.33

4

7/1.961

5.88

1.02

8.02

0.13

8.28

0.84

4

19/1.200

6.00

1.02

8.14

0.13

8.40

0.84

4

105/0.511

6.85

1.02

8.99

0.13

9.25

0.84

4

168/0.404

6.85

1.02

8.99

0.13

9.25

0.84

4

420/0.254

6.81

1.02

8.95

0.13

9.21

0.84

2

7/2.473

7.42

1.02

9.56

0.13

9.82

0.53

2

19/1.510

7.55

1.02

9.69

0.13

9.95

0.53

2

266/0.404

8.62

1.02

10.76

0.13

11.02

0.53

2

312/0.370

8.55

1.02

10.69

0.13

10.95

0.53

2

672/0.254

8.62

1.02

10.76

0.13

11.02

0.53

1

7/2.780

8.34

1.27

10.98

0.18

11.34

0.42

1

19/1.690

8.45

1.27

11.09

0.18

11.45

0.42

1

209/0.511

9.67

1.27

12.31

0.18

12.67

0.42

1

340/0.400

9.52

1.27

12.16

0.18

12.52

0.42

1

396/0.370

9.06

1.27

11.70

0.18

12.06

0.42

1

840/0.254

9.50

1.27

12.14

0.18

12.50

0.42

1/0

191.900/

9.50

1.27

12.14

0.18

12.50

0.33

1/0

266/0.511

10.28

1.27

12.92

0.18

13.28

0.33

1/0

418/0.404

10.93

1.27

13.57

0.18

13.93

0.33

1/0

498/0.370

10.93

1.27

13.57

0.18

13.93

0.33

1/0

1056/0.254

9.45

1.27

12.09

0.18

12.45

0.33

2/0

19/2.130

10.65

1.27

13.29

0.18

13.65

0.26

2/0

329/0.511

12.27

1.27

14.91

0.18

15.27

0.26

2/0

532/0.404

12.33

1.27

14.97

0.18

15.33

0.26

2/0

630/0.370

12.29

1.27

14.93

0.18

15.29

0.26

2/0

1330/0.254

12.26

1.27

14.90

0.18

15.26

0.26

3/0

19/2.390

11.95

1.27

14.59

0.18

14.95

0.21

3/0

418/0.511

13.83

1.27

16.47

0.18

16.83

0.21

3/0

666/0.404

13.80

1.27

16.44

0.18

16.80

0.21

3/0

795/0.370

13.81

1.27

16.45

0.18

16.81

0.21

4/0

19/2.680

13.40

1.27

16.04

0.18

16.40

0.17

4/0

513/0.520

15.59

1.27

18.23

0.18

18.59

0.17

4/0

840/0.404

15.50

1.27

18.14

0.18

18.50

0.17

4/0

999/0.370

15.48

1.27

18.12

0.18

18.48

0.17


Q: What is the outer diameter of the copper cable 3 * 25 + 2 * 16? What is the cable diameter of 4 * 50 + 1 * 25?
Sailing cold drill. The The Cool cold supreme. The The Pioneer (burner). The The
Q: is it possible to run a 2-wire AC power cable (2x2.5mm2 or thicker) from the telephone junction box to the inside of the house instead of using an ordinary thin phone cable? will that affect the voice quality or maybe an ADSL setup? the distance is approximately 50 meters.thanks a lot.
telephone wire is twisted pair.. which reduces interference, and induction problems... using electrical cable in place of phone cable would work but not without acting like an antenna and picking up all kinds of back ground interference... as well as potentially degrading the signal for your DSL...
Q: i have 2 xbox 360s; one german one american, only problem is my american one(110 volts) has lost its power cable, now i thought why not just use the german (220 volt) power cable; but im afraid that might blow up the cable or whatever, any suggestions??
right, the power outage would be too high
Q: Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
Power cable YJV22-8.7 / 15kv-3 * 300 Meaning: refers to the copper core XLPE insulated double steel tape armored PVC sheathed power cable, cable rated working voltage 8.7 / 15KV, cable for the three-core, single Conductor cross-sectional area of 300mm2. YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated working voltage 8.7 / 15 kV 3 * 300 Specifications: YJV22-8.7 / 15kv-3 * : Three conductors, single cross section of 300 square feet.
Q: Single single 10kV power cable with copper shield can wear steel pipe? What will be the impact?
. the first two said two cables, KW is KVV that PVC insulated jacket control cable. . the control cable for industrial and mining enterprises, energy and transportation sector, for the exchange rated voltage 450/750 volts below the control, protection lines and other occasions, the use of PVC insulated, PVC sheathed control cable. . the performance difference: the power cable in the main line of power systems used to transmit and distribute high-power power, control cable from the power system distribution point of electricity directly to a variety of electrical equipment, power equipment, power lines. The rated voltage of the power cable is generally 0.6 / 1kV and above, the control cable is mainly 450 / 750V. The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick.
Q: I have my Clearwire modem but have lost the power cable. Does anyone know what I would look for in a replacement power cable.
Try contacting the manufactor. They usaully have spare parts.
Q: My power cable says it is plug in but will not charge it. What is wrong?
It could be your cable or power supply unit went bad. Or, your power socket on the main board went south. The good thing about laptops is that the power supply unit is external and easy to swap out.
Q: my laptop power cable is pluged in and turned on but it fails to charge or power my laptop but its in properly and sumtimes works .. any help?
ok....this might not be you power supply cable.. this may be a problem with your powerjack in your laptop, if that's loose, then it won't recieve any power from the cable...it will randomly though..i had the same problem a few months ago, and a little solder job will do the trick! take it to a good local repair guy (or me if you're in the uk hahaha)... and have the power jack resoldered.. try your power supply on another similar laptop to make sure it's not that..but generally speaking..once a power supply's fried..it won't work randomly...all it is, is a transformer and a converter... it would make sense if it was the power jack loose or has a faulty connection to the motherboard :) hope this helped!
Q: Hello,We are having a problem with our power cable and that being that most time whenever we insert the power cable into the back of the laptop the orange light at the front of the laptop does not always light up. We think the problem lays with the power cable, because it has been tugged and dropped before on many occasion.So, is it possible to buy a power cable for our Toshiba laptop, and we have retained the sticker. We think that the Toshiba part no is PA3396E-1ACA and the model no is PA-1650-02.So is it possible to buy a new power cable?
it sounds as if the jack plug on the board needs doing. it is a common problem and reasonable in cost to repair.
Q: How do power-station-cable thieves manage to get away without being electrocuted?