This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.
TYPE | Concentrated Load | Impact Load | Ultimated Load | Uniform Load | Rolling Load | |||
LB | N | KG | N | N | N/㎡ | 10passes | 10000passes | |
HGD600-Q | ≥800 | 3550 | 363 | 670 | ≥9400 | ≥14680 | 3560 | 2670 |
HGD600-B | ≥1000 | 4450 | 453 | 670 | ≥11970 | ≥16900 | 4450 | 3560 |
HGD600-Z | ≥1250 | 5550 | 567 | 670 | ≥14360 | ≥22240 | 5560 | 4450 |
HGD600-CZ | ≥1500 | 6660 | 680 | 780 | ≥17950 | ≥26690 | 6670 | 5560 |
Features
Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available
Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.
Pedestal and Stringer
Installed Example
HPL Colour Card
8063 | 8117 | 8119 |
8132 | 8137 | 8138 |
8144 | 8156 | 8191 |
8192 | 8193 | 8194 |
8213 | 8311 | 8312 |
BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.
Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.
Why an Access Floor?
* Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.
* As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.
* Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.
* In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors.
- Q: The difference between plastic floors
- The difference between plastic floors...
- Q: How to install anti-static floor
- Step: 1, floor cleaning; 2, carefully check the surface flatness and perpendicularity of the walls, such as found not to meet the construction requirements, the departments concerned party; horizontal pull, the well floor mounting height with elastic ink line on the wall, ensure that the laying of the floor at the same level, the measuring chamber length, width, and appropriately select the laying reference position to reduce the cutting floor. the installation grid lines bracket the ground; to be mounted bracket is adjusted to the height of the same needs and the stent Ling Li and Gu pad pedicle cutting jig placed slightly bite into the ground of the cross grid lines; 3, with the screw secured to the frame beams, and with a spirit level n beams, perpendicular to each other and so that on the same plane ; with a suction plate is placed on the transom in the assembled floor: the square by four, if the size is less than the remaining wall length of the floor itself, the available methods for cutting floor fight Lee; 5, Edge; 6, clean up the site, completed; note 1, when the laying of the floor, with a bubble level leveling, the height adjustment bracket on the floor; 2, placing heavy apparatus at the room, the device should be in the base The lower plate installation bracket to prevent deformation of the floor; 3, when the floor needs to be cut or opening, the application opening in the corner drill hit Φ6mm-Φ8mm circular, veneer prevent breakage.
- Q: Antistatic floor which inspection lot should be used
- Antistatic flooring which inspection lot to adopt
- Q: To the customer made a conference system, including the LCD splicing screen and sound system, due to the sake of the carpet electrostatic extravagance of the United States and the United States and the United States, the United States and the United States, , The equipment on the cabinet, including the mixer, amplifier, timing power, wireless microphone receiver. Do not know how to ground to eliminate static electricity, is the equipment alone or to the cabinet grounding on the line? Gooseneck microphone how to ground? How are these devices connected to the ground? What materials do you need? Trouble you to the article Ming Road, brother do not understand, first thanked in the past. More
- In the room plus a humidifier, static electricity will not be so powerful
- Q: PVC anti-static floor of the anti-static index is how much
- Anti - static plastic floor of the technical parameters
- Q: PVC pipe with anti-static performance?
- Pvc tube is not anti-static but there is anti-static pvc tube
- Q: Which anti-static floor is the best quality?
- Domestic strength and brand strength are several: Shen Fei, Huatong, East China ah generally small room are only supplied with no muscle Shan crown catch 攉 non-Kyu stone helium will be installed, how much area is you? Need to leave a message
- Q: Will static electricity cause a fire?
- Under certain conditions will cause a fire!
- Q: Would like to ask epoxy anti-static self-leveling a few processes?
- This depends on how thick you are.
- Q: Antistatic aerial floor how much money a square meter?
- Common anti-static floor between 180-240 including the keel ~ ~
Send your message to us
Raised Floor with HPL finish(Steel Panel)
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5000 g/m²
- Supply Capability:
- 50000 g/m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords