Raised Floor with HPL finish(Steel Panel)
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5000 g/m²
- Supply Capability:
- 50000 g/m²/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
aised Floor with HPL finish(Steel Panel)
Model: HGD600
Dimension: 600×600×35/30(mm)
This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.
TYPE | Concentrated Load | Impact Load | Ultimated Load | Uniform Load | Rolling Load | |||
LB | N | KG | N | N | N/㎡ | 10passes | 10000passes | |
HGD600-Q | ≥800 | 3550 | 363 | 670 | ≥9400 | ≥14680 | 3560 | 2670 |
HGD600-B | ≥1000 | 4450 | 453 | 670 | ≥11970 | ≥16900 | 4450 | 3560 |
HGD600-Z | ≥1250 | 5550 | 567 | 670 | ≥14360 | ≥22240 | 5560 | 4450 |
HGD600-CZ | ≥1500 | 6660 | 680 | 780 | ≥17950 | ≥26690 | 6670 | 5560 |
Features
Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available
Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.
Pedestal and Stringer
Installed Example
HPL Colour Card
8063 |
8117 |
8119 |
8132 |
8137 |
8138 |
8144 |
8156 |
8191 |
8192 |
8193 |
8194 |
8213 |
8311 |
8312 |
BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.
Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.
Why an Access Floor?
* Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.
* As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.
* Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.
* In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors.
- Q: Brief description of anti-static floor function and construction practices?
- Google Encyclopedia some, very detailed ...
- Q: Anti-static PVC board where the use of, please give details of Thank you very much! The The Questions added: or what type of business with anti-static board, the best example Thank you ~ ~ more
- Generally used for the production of anti-static floor, electronics and semiconductor industry used a lot, is the most cost-effective anti-static floor materials....
- Q: How to install anti-static floor
- Step: 1, floor cleaning; 2, carefully check the surface flatness and perpendicularity of the walls, such as found not to meet the construction requirements, the departments concerned party; horizontal pull, the well floor mounting height with elastic ink line on the wall, ensure that the laying of the floor at the same level, the measuring chamber length, width, and appropriately select the laying reference position to reduce the cutting floor. the installation grid lines bracket the ground; to be mounted bracket is adjusted to the height of the same needs and the stent Ling Li and Gu pad pedicle cutting jig placed slightly bite into the ground of the cross grid lines; 3, with the screw secured to the frame beams, and with a spirit level n beams, perpendicular to each other and so that on the same plane ; with a suction plate is placed on the transom in the assembled floor: the square by four, if the size is less than the remaining wall length of the floor itself, the available methods for cutting floor fight Lee; 5, Edge; 6, clean up the site, completed; note 1, when the laying of the floor, with a bubble level leveling, the height adjustment bracket on the floor; 2, placing heavy apparatus at the room, the device should be in the base The lower plate installation bracket to prevent deformation of the floor; 3, when the floor needs to be cut or opening, the application opening in the corner drill hit Φ6mm-Φ8mm circular, veneer prevent breakage....
- Q: Ceramic anti-static flooring and PVC anti-static floor which is good wave tripod anti-static floor to tell you
- As far as I know, the ceramic is better.
- Q: How to drill holes in the engine room? Drill a good hole after drilling a good hole?
- Open the hole with a cutter and then plug it up
- Q: How to lift the UPS static electricity
- The UPS is static because the ground is not connected because of the sinking of the socket. The role of anti-static floor is to prevent people walking on the floor when the human body to produce static electricity, and the role of different ground.
- Q: PVC pipe with anti-static performance?
- There are anti-static pipe, such as coal mine gas pipe, ic package tube has anti-static requirements
- Q: Machine room length 7.6m, width 5.3m, about 40 square meters, the existing grounding copper belt 100m, specifications 3X30MM, insulated helium for the reclamation of the old rush to protect the child 10cm / sets, 100 sets, tin plating busbar 8 * 100 * 400mm, 1 set, lightning down ground, specifications 50mm2,1m, ground terminal, specifications 4 * 40 * 400 + 2000mm flat steel, 1 item. Room electrostatic floor there are others to do we only mine, I would like to ask 1, the room needs to be connected to the number of copper meters? 2, the above products how to do lightning protection grounding specific steps and what to pay attention to. 3, horizontal ground and electrostatic floor between the height of 15cm enough? (Between the ground and the electrostatic floor has a 10cm high trough) is best to give a set of programs, to help me solve the problem to the 100 Thank you more
- 1, the room needs to be polished copper how many meters? The number: can be as follows: 26m, 140m, the middle value can be. This is not a strict sense of the request, if the budget is sufficient to calculate by 140m. 2, the above products how to do lightning protection grounding specific steps and what to pay attention to. Lay near the electrostatic floor support, pay attention to the copper belt and other equipment and other connections. 3, the level of the surface of the helium for the reclamation of the old rush between the tacit and electrostatic floor between the height of 15cm enough? Adequate, generally recommended best attached to the ground. Not high and low under the floor how to go under the track, maintenance and maintenance of the latter part of the time are trouble.
- Q: Is the insulation floor and the anti - static floor the same thing?
- Anti-static floor is insulated floor, insulated floor is not necessarily anti-static. If you have more questions, you can click on ID consultation.
Send your message to us
Raised Floor with HPL finish(Steel Panel)
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5000 g/m²
- Supply Capability:
- 50000 g/m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords