Model: HGD600

Dimension: 600×600×35/30(mm) 

 

This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.

TYPE Concentrated Load Impact Load Ultimated Load Uniform Load Rolling Load
 LB N KG N N N/ 10passes10000passes 
HGD600-Q  800 3550363 670 ≥9400 ≥14680 3560 2670
HGD600-B ≥1000 4450 453 670 ≥11970 ≥16900 4450 3560
 HGD600-Z ≥1250 5550567 670 ≥14360 ≥22240 5560 4450
 HGD600-CZ ≥1500 6660680 780 ≥17950  ≥26690 6670 5560


Features
  


Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available

 

Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.

 Pedestal and Stringer 

 

         

Installed Example 

 

HPL Colour Card 

 

8063

 

8117

 

8119

 

8132

 

8137

 

8138

 

8144

 

8156

 

8191

 

8192

 

8193

 

8194

 

8213

 

8311

 

8312

 


BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.


Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.


Why an Access Floor?


*     Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.

*     As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.

*      Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.

*      In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors. 

                                          


Q: Can flooring replace the antistatic floor?
Can not
Q: What is the anti-static floor edge material
The edge of the edge of the plant with the material is not sturdy shield box Yong Valley fall Yan Kai Kai, there are all steel, there are alloys, PVC, etc., as long as the conductive, are in use, the price is low to the provincial cost of the principle, Good quality to use good materials, there are no side of the floor.
Q: What kind of chair will not damage the anti-static floor
Below with wheels ,so cool.
Q: All-steel ceramic anti-static floor. How can you open the hole? Used to take the line. What tools can I open the hole at once? Question added: .. both brick and brick but also ceramic tiles have not? To open the hole, what turned around? More
Although the tile is beautiful, but to punch on the tile is not an easy thing. Because the tile itself is easy to bad plus a hole is easier to break along the gap. Method / Step 1 ? The position to be punched is pre-calibrated to ensure the level. (Note that the corresponding location of the wall do not have water and electricity lines) 2, with a glass drill hole in the ceramic tile, the first tilt direction to play a pit; otherwise the tile is too smooth and bad positioning; or not all tiles, with nails directly A small pit to come; think about precision, you can also have a hole (size appropriate) plate with the best. 3, set out to play a small mark can remove the positioning of the orifice, and then. Prepare a bottle in advance, drill a hole in the bottle, the bottle filled with water. Then, when the hole to the water at the same time to the drill bit and tile contact parts; especially the whole tile, be sure to have water Oh. 4, there is no need to change the impact of the drill. Open the tile part, continue to play the screw depth. Attention to play a hole, remove the glass drill, the blocked part of the drill bit to clear the hollow. (All the tiles in particular to do this step).
Q: The anti-static floor of the engine room with any suitable baseboard
Overhead activities are generally not equipped with the base of the floor, straight shop antistatic tile with a baseboard is more common, are generally ceramic black baseboard, better with some.
Q: Anti-static floor material classification
1, all-steel anti-static floor 2, clean room all-steel anti-static floor 3, protective-type anti-static floor 4, ceramic surface anti-static floor - metal composite activities floor 5, all steel anti-static ventilation plate 1, Anti-static ventilation board 2, aluminum grille plate 3, aluminum alloy blind plate 1, reinforced composite anti-static floor 2, anti-static ceramic steel composite flooring 1, straight pvc anti-static floor, permanent PVC anti-static floor 1, all steel 0A network floor
Q: PVC pipe with anti-static performance?
Pvc tube is not anti-static but there is anti-static pvc tube
Q: How to clean the room floor
Clean water with clean toilet and brush!
Q: Machine room length 7.6m, width 5.3m, about 40 square meters, the existing grounding copper belt 100m, specifications 3X30MM, insulated helium for the reclamation of the old rush to protect the child 10cm / sets, 100 sets, tin plating busbar 8 * 100 * 400mm, 1 set, lightning down ground, specifications 50mm2,1m, ground terminal, specifications 4 * 40 * 400 + 2000mm flat steel, 1 item. Room electrostatic floor there are others to do we only mine, I would like to ask 1, the room needs to be connected to the number of copper meters? 2, the above products how to do lightning protection grounding specific steps and what to pay attention to. 3, horizontal ground and electrostatic floor between the height of 15cm enough? (Between the ground and the electrostatic floor has a 10cm high trough) is best to give a set of programs, to help me solve the problem to the 100 Thank you more
1, the room needs to be polished copper how many meters? The number: can be as follows: 26m, 140m, the middle value can be. This is not a strict sense of the request, if the budget is sufficient to calculate by 140m. 2, the above products how to do lightning protection grounding specific steps and what to pay attention to. Lay near the electrostatic floor support, pay attention to the copper belt and other equipment and other connections. 3, the level of the surface of the helium for the reclamation of the old rush between the tacit and electrostatic floor between the height of 15cm enough? Adequate, generally recommended best attached to the ground. Not high and low under the floor how to go under the track, maintenance and maintenance of the latter part of the time are trouble.
Q: Will the silk be static?
I have learned that the same is true of electricity from the glass rods worn with silk, called positive electricity; and rubber bands that have been rubbed with fur. The same electricity is called negative.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords