aised Floor with HPL finish Steel flooring
Model: HGD600
Dimension: 600×600×35/30(mm)
This product is made of quality steel plate, which is stretched forming, point welded and plastic sprayed with bubble cement filler filled in its inner cavity. The fire-resistant decoration plates that can endure high temperature adhere to its surface with conductive chips embedded around it. The pedestals and cross beams are wholly plated with zinc and the height of pedestals is adjustable and can be self-locked.
TYPE | Concentrated Load | Impact Load | Ultimated Load | Uniform Load | Rolling Load | |||
LB | N | KG | N | N | N/㎡ | 10passes | 10000passes | |
HGD600-Q | ≥800 | 3550 | 363 | 670 | ≥9400 | ≥14680 | 3560 | 2670 |
HGD600-B | ≥1000 | 4450 | 453 | 670 | ≥11970 | ≥16900 | 4450 | 3560 |
HGD600-Z | ≥1250 | 5550 | 567 | 670 | ≥14360 | ≥22240 | 5560 | 4450 |
HGD600-CZ | ≥1500 | 6660 | 680 | 780 | ≥17950 | ≥26690 | 6670 | 5560 |
Features
Designed specially for computer room&clean room
Excellent rolling load & ultimate load performance
Light weight cementitious fill makes panels solid and quiet
Completely non-combustible
Black electrodeposition cathodic epoxy paint finish for life time protection
Class A flame spread and smoke development rating
Wide range of finishes available
Applicable Fields
Computer rooms, programmed control equipment rooms, electrical-controlled classrooms, places that have requirements of dust-proof and anti-static, and fields with aerial requirements.
Pedestal and Stringer
Installed Example
HPL Colour Card
8063 | 8117 | 8119 |
8132 | 8137 | 8138 |
8144 | 8156 | 8191 |
8192 | 8193 | 8194 |
8213 | 8311 | 8312 |
BEISIDE® computer, server, control room, and general office access floors is China fastest growing raised access-flooring manufacturer. HUIYA help design and create smarter buildings utilizing HUIYA's state of the art raised flooring systems to help organize your voice and data requirements. Create your intelligent building by using the access floor as an open-air plenum. With over 10 years of experience around the construction industry, HUIYA is committed to being part of the solution.
Businesses have responded quickly and dramatically to rapid technological changes over the last several years. Yet, building systems have been slow to accomodate these demands. Changes to office environments continue to be disruptive, slow and wasteful. Repairs to sensitive equipment and data remains unnecessarily high. Environmental efficiency and comfort is more important than ever. HUIYA's Raised Access Flooring systems eliminate the need for embedded wiring and provides instant access to wiring and cabling, allowing for quick and easy reconfiguration of your office space. HUIYA has the technology to address advances in electronic work flow, conservation and occupant comfort.
Why an Access Floor?
* Construction programmes are reduced by at least two weeks per floor due to elimination of a sand cement screed.
* As warm air rises, considerable cost savings are achieved by an underfloor air plenum delivering conditioned air exactly where it is needed - compared with the traditional uneconomic alternative of forcing conditioned air from the ceiling.
* Maximum flexibility for the installation and reconfiguring of services to equipment and workstations a matter of hours.
* In new construction the use of an access floor for total service distribution reduces the overall building height by about 13%. Or, for the same height, you can increase the number of floors.
- Q: Can flooring replace the antistatic floor?
- Yes, need to be soft ground or with electrostatic sensitive parts, other conductors and other potentials. Further need to study the upper and lower limits to the practical requirements.
- Q: Whether the floor is suitable for flooring on the floor
- OA flooring need to shop the carpet, the general floor of the static floor do not need to shop the carpet, of course, if it is important to the conference room room or something, in order to more beautiful and then lay a layer of electrostatic carpet can be.
- Q: PVC anti-static floor of the anti-static index is how much
- Anti - static plastic floor of the technical parameters
- Q: The anti-static floor of the engine room with any suitable baseboard
- Generally do not have the baseboard it has to install optional PVC or tile, can not choose the wood
- Q: Composite anti-static floor with an empty one square meter how much money
- Please enter your answer here, each composite anti-static floor with an aerial one square meter how many professional solutions will create your authority image
- Q: How many anti-static floor with feet and beams
- A square anti-static floor, the ratio of feet is 3.5, beam ratio is 5.5, an anti-static floor 0.36 square, calculated down, an anti-static floor foot ratio is 1.26, beam ratio of 1.98, do the project are generally So the ratio, if the wholesale, that ratio will be much less, should be wide floor professional to do the project, so the fight against the attack Jiqiu fluttering Wei Wei two pieces are according to this ratio, in summary, that 100 Block floor, feet to be equipped with 126, beam 198, 396 screws, a beam with 2 screws, and so on
- Q: Is the beige flooring nice? A long time will not change color?
- Yes, as long as the quality of qualified, generally will not change the color. Floor, ie the surface of the building floor or floor. Made of wood or other material. There are many types of flooring, according to the structure classification: solid wood flooring, laminate flooring, solid wood flooring, bamboo flooring, cork flooring and the most popular multi-layer parquet, etc .; by use classification: home, commercial , Anti-static floor, outdoor flooring, stage dance dedicated floor, sports hall floor dedicated floor, track and field floor, etc .; according to environmental protection classification: E0 floor, JAS star standard F4 star floor and so on.
- Q: Is there any difference between anti-static flooring and insulation mats or anti-static floor insulation? Ask the master to advise more
- Anti-static floor is insulated floor, insulated floor is not necessarily anti-static
- Q: Construction of weak and fire control room must do anti-static floor? Has there been any impact on future acceptance?
- Not have to do, but it is best to do anti-static floor, generally with anti-static steel floor, the general price as long as more than one hundred square. If you do not install anti-static floor, the acceptance must be affected, in order to ensure the acceptance is acceptable, I suggest you still use anti-static floor.
- Q: Would like to ask epoxy anti-static self-leveling a few processes?
- Primer - mortar in the coated - paste conductive copper foil - scraping conductive putty - steamed bread anti-static epoxy self-leveling paint!
Send your message to us
Raised Floor with HPL finish Steel flooring
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 4000 g/m²
- Supply Capability:
- 50000 g/m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords