Network Raised Floor(Bare Panel)

Dimension: 500×500×28(mm)

 

Products Shape / Variations 

 Panel Type

 OA500S

 OA500C

 Product shape

  

 

 

 TYPE

 Concentrated Load

 Impact Load

 Ultimated Load

 Uniform Load

 Rolling Load

 LB

 N

 KG

 N

 N

 N/

 10passes

10000passes 

OA500S-Q
OA500C-Q

 ≥800

 3550

363

 670

 ≥9400

 ≥14680

 3560

 2670

OA500S-B
OA500C-B

 ≥1000

 4450

 453

 670

 ≥11970

 ≥16900

 4450

 3560

 

A four-square independently supports the structure. The upper board is made
from extra-hard steel board, and the lower board has been pulled deeply. The
flooring surface is processed with anti-static coating, and the inside is filled
with foamed cement. Zinc plating is used for the base support, and the height can
be adjusted and locks automatically. The rounds of the floor have cut-line and rivet
joints to make the shape.

OA Steel Panel is composed of whole-steel flooring, whole-steel support,
anti-static carpeting and other finishes. This high-intensity flooring has a high
load capacity and is fire, moisture, and static-proof.

Features:
1) Long use life, compact size, easy to change and maintain, flexible, reusable
2) Easy to install
3) Whole-steel construction, impact-resistant, scuff-resistant, corrosion-proof
4) High regulating range of 35 ~ 150mm
5) Comfortable to walk on, appealing to look at
6) Abundant space for wiring
7) Suitable for top-grade office buildings, computer labs, classrooms,
network rooms, and other areas that require comprehensive wiring
 

Pedestal  

                                                              

                 Cross Head Pedestal                                                  Border Pedestal


Q: The room and shop the floor and the use of static wiring on the bridge wiring, scientific and reasonable?
Yes ah this is nothing is unreasonable is a practical request Many telecommunications room are used, Hengtong Xin Hong anti-static floor...
Q: Selling and selling anti-static flooring which is easy
That is not easy, there is no easy work, Hengtong Xin Hong anti-static floor
Q: How to lift the UPS static electricity
The UPS is static because the ground is not connected because of the sinking of the socket. The role of anti-static floor is to prevent people walking on the floor when the human body to produce static electricity, and the role of different ground.
Q: An electrostatic pad (static skin to be separated by a large amount of static electricity installed in the installation of an electrostatic buckle, such as an electrostatic pad length of 5M? The More
Yes, you can look at their own anti-static mats, are generally two layers of green (blue, gray) under the black waste 禒 irrigation Pi Piao anti-lion set the upper layer for the anti-static layer, the surface resistivity of 10 ^ 6 ~ 10 ^ 9 ohm, the lower layer for the conductive layer, the surface resistivity of less than 10 ^ 5 ohm lower conductive, no matter how far, as long as a table mat, there is a ground button can be able to connect the whole table mats, of course, you More than a few also may wish, may be due to mechanical reasons, the ground button line may be broken
Q: How to ground the antistatic floor
Follow the ground, OK to adopt
Q: Room cabinet from the UPS distribution cabinet to take power, anti-static floor below the need to put a socket? Please recommend several commonly used
Direct PDU on the line.
Q: Will static electricity cause a fire?
Under certain conditions will cause a fire!
Q: How is the floor of the anti-static floor?
Anti-static floor (including ceramic anti-static floor) in the laying, be sure to carry out anti-static grounding and then protect the resistance box, so as to play the effect of anti-static effect. In the anti-static grounding process ground connection is mainly used for anti-static pad grounding connection between the ground can be effective in the production work of the human body or table mats generated by the electrostatic discharge of the battery into the earth. There will be a fixed bracket and so on ~
Q: Antistatic floor of the construction skills of what
Network floor outlet can be used to match the junction box (box with strong, weak socket) or in the cover on the outlet access to fixed in the work under the aluminum plate or furniture on the strength of the strong electrical outlet. When the furniture changes, the junction box outlet can be moved to the new address. If you long track Beike long flap hugs ready to decorate, need to buy building materials and furniture can go to a home network.