• Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire System 1
Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire

Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000kgs kg/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

Grade 4214Q is sioplas (two steps) silane XLPEcompound for low voltage cable with small cross sectional area, it is composed by silane crosslinkable low density polyethylene (compound A) and silane crosslinkable catalyst (compound B). Compound A is grafted by high activity silane and special PE compound, while compound B adopts the advanced cataly stsystem. The product has outstanding performance and major characteristics are

◆The product is suitable for the extrusion method of squeezing extrusion,half-tubing extrusion and tubing extrusion.

◆Cables made from the product have excellent performance in smooth cable surface, high extrusion speed and production efficiency.

◆Suitable for cable cross-sectional area less than 16mm2.

Standard

Performance test is in accordance with JB/T 10437-2004 standard. After crosslinked in the tepid water, the cable made from the product grade 4214Q can comply with the standard of IEC60502-2004, GB/T12706-2002.

Main Properties & Typical Values

Test items

Test method

Unit

Standard

Typical value

Tensile strength

GB/T1040.3

MPa

≥14.0

19.0

Elongation at break

GB/T1040.3

%

≥350

480

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change

Maximum elongation at break change

GB/T8815

%

%

±20

±20

-12

-5

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load

Maximum permanent elongation change after cooled

GB/T2951

%

%

≤80

≤5

68

-4

Dielectric strength

GB/T1408.1

MV/m

≥30

43*

Volume resistance (20℃)

GB/T1410

Ω.m

≥1.0×1014

3.5×1014*

Gel content

JB/T 10437

%

≥60

60

Typical values were tested on the 1mm sample strip by squeezing film extrusion after mixing compound of A& B (at percentage of 95:5) and be boiled in hot water at 90℃for four hours.

*Especially, these typical values were tested by press moulding sample under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for four hours.

Recommended Processing Technique

1.   Extrusion Equipment

Most extruders for PVC and PE suit for 4214Q.

The recommended equipment and processing technique is as following.

Ratio of length and diameter                    18—25:1

Diameter                                                45—120mm

Ratio of compressing                              1.5—3.5

Ratio of elongation                                  1:1.0—1:1.5

Filtering mesh                                         40/60/40

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should bebased on different equipment and pressing conditions, reference settings are as following:

Feeding section(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

150~165

165~175

175~190

190~200


Die head setting:
Squeezing extrusion style, half-tubing extrusion style and tubing extrusion style

Cooling water temperature: Should not beless than 25℃,gradual cooling water tank is recommended.

   

3.   Crosslink

After extrusion and cooling, the cable can be crosslinked by immersed in hot water (90℃) or exposed in low pressure vapour. The time required for crosslink is based on the thickness of the insulation and the coil size, the thicker the insulation and the greater the coil size, the longer the crosslink time required. The crosslink time canbe calculated according to the equation of 4hr/mm for 90℃.


Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
No way to save money! Moreover, the signal to you there, almost all attenuation finished.
Q: What brand of cable is good, what are the top ten brands of wires?
If you are talking about the three-core wire, black - ground brown - line of blue - zero line. If it is 3 plugs, your wire is only 2 lines. Then the yellow received L, black received N. The above is the ground wire.
Q: Apple 6splus charge may not support this accessories how to do more
Sometimes no way, the problem to the owners to solve the common, must wear, the owners agreed
Q: What is the difference between wires and cables?
The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
Q: What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q: Wire and cable model ZD what does it mean
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q: What are the varieties of wire and cable (detailed point)
Cable regardless of the definition of the number of elements in the definition of a few such as: YJV-3 * 50 + 1 * 16 calculated the number of lines is always a different, different wire rules Model input: bv-2 * 2.5 / bv-3 * 4 (different material), bv-2 * 2.5 + 3 * 4 (the same material)
Q: What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
Make a mark, such as red set into the bottom for a color in a layer, or you can draw a few plans, water and electricity is a strong power is a weak and one, the label can do a good job
Q: What are the T and T, s of the wire and cable test type?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!
Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!