• Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire System 1
Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire

Quick Extruding Silane Cross-Linkable PE Compound for 3KV and Below Cable Wire

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000kgs kg/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

Grade 4214Q is sioplas (two steps) silane XLPEcompound for low voltage cable with small cross sectional area, it is composed by silane crosslinkable low density polyethylene (compound A) and silane crosslinkable catalyst (compound B). Compound A is grafted by high activity silane and special PE compound, while compound B adopts the advanced cataly stsystem. The product has outstanding performance and major characteristics are

◆The product is suitable for the extrusion method of squeezing extrusion,half-tubing extrusion and tubing extrusion.

◆Cables made from the product have excellent performance in smooth cable surface, high extrusion speed and production efficiency.

◆Suitable for cable cross-sectional area less than 16mm2.

Standard

Performance test is in accordance with JB/T 10437-2004 standard. After crosslinked in the tepid water, the cable made from the product grade 4214Q can comply with the standard of IEC60502-2004, GB/T12706-2002.

Main Properties & Typical Values

Test items

Test method

Unit

Standard

Typical value

Tensile strength

GB/T1040.3

MPa

≥14.0

19.0

Elongation at break

GB/T1040.3

%

≥350

480

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change

Maximum elongation at break change

GB/T8815

%

%

±20

±20

-12

-5

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load

Maximum permanent elongation change after cooled

GB/T2951

%

%

≤80

≤5

68

-4

Dielectric strength

GB/T1408.1

MV/m

≥30

43*

Volume resistance (20℃)

GB/T1410

Ω.m

≥1.0×1014

3.5×1014*

Gel content

JB/T 10437

%

≥60

60

Typical values were tested on the 1mm sample strip by squeezing film extrusion after mixing compound of A& B (at percentage of 95:5) and be boiled in hot water at 90℃for four hours.

*Especially, these typical values were tested by press moulding sample under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for four hours.

Recommended Processing Technique

1.   Extrusion Equipment

Most extruders for PVC and PE suit for 4214Q.

The recommended equipment and processing technique is as following.

Ratio of length and diameter                    18—25:1

Diameter                                                45—120mm

Ratio of compressing                              1.5—3.5

Ratio of elongation                                  1:1.0—1:1.5

Filtering mesh                                         40/60/40

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should bebased on different equipment and pressing conditions, reference settings are as following:

Feeding section(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

150~165

165~175

175~190

190~200


Die head setting:
Squeezing extrusion style, half-tubing extrusion style and tubing extrusion style

Cooling water temperature: Should not beless than 25℃,gradual cooling water tank is recommended.

   

3.   Crosslink

After extrusion and cooling, the cable can be crosslinked by immersed in hot water (90℃) or exposed in low pressure vapour. The time required for crosslink is based on the thickness of the insulation and the coil size, the thicker the insulation and the greater the coil size, the longer the crosslink time required. The crosslink time canbe calculated according to the equation of 4hr/mm for 90℃.


Q: The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
Q: What machinery is required to make wire and cable?
Pouring concrete when you can line? Do you clear the problem?
Q: Ipad not charge how the matter. Said the cable or accessories have not been certified, and may not be able to cooperate with this ipad reliable work....
Several sets of cables in the same height of the laying, the adjacent cable between the bridge should be considered maintenance, maintenance needs, generally not less than 0.6m. This is just a matter of theory, it does not matter. Anyway, the actual construction is to do so,
Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
At the same time, security monitoring line itself is a weak line
Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
Directly to find Dell customer service bar, the general warranty period are free replacement, unless the insurance of the. You can extend the warranty period, it seems you like to do the experiment.
Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
You are not very clear: how to start again? 300μF capacitor is normal? If the sound is normal (very small) after no-load start, the cable and the motor temperature are normal, the coil can be judged to be normal
Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
Can not be removed, and so on after the first line of fluoride, and then demolition of air conditioning.
Q: Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
Cable is a unified call, including power cables, communication cables, etc., I do not know what type of cable you need the type specifications. On the power cable in terms of the main models are: VV, BJV, VV. BJV. . ZR, NH and other models, as the specifications that too much.
Q: What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!