Specifications of Cable Conductor HS137
ACSR Conductor Cable
1.Conductor:Hard drawn aluminium wire
2.Steel core:Galvanized steel wire,solid or concentric stranded
ACSR Conductor, Reinforced pecifications of Cable Conductor HS137
Aluminum Conductors Steel Reinforced ACSR ASTM B 232 Specifications of Cable Conductor HS137
Area |
Stranding and wire diameter |
Approx. overall diameter |
Weight |
Nominal breaking load |
Nominal DC resistance at 20 deg. | ||||||
Nominal |
Alum. |
Steel |
Total |
Alum. |
Steel |
Alum. |
Steel |
Total | |||
AWGorMCM |
mm2 |
mm2 |
mm2 |
mm |
mm |
mm |
Kg/km |
Kg/km |
Kg/km |
kN |
Ohm/km |
1272 |
644.51 |
81.68 |
726.19 |
54/3.90 |
19/2.34 |
35.10 |
1795 |
638 |
2433 |
194.00 |
0.04516 |
1272 |
644.51 |
17.87 |
662.38 |
36/4.78 |
1/4.78 |
33.42 |
1777 |
140 |
1917 |
115.85 |
0.04472 |
1351.5 |
684.84 |
47.10 |
731.94 |
45/4.40 |
7/2.92 |
35.16 |
1898 |
368 |
2266 |
160.70 |
0.04230 |
1351.5 |
684.84 |
86.71 |
771.55 |
54/4.02 |
19/2.41 |
36.17 |
1906 |
679 |
2585 |
206.05 |
0.04250 |
1431 |
725.10 |
50.32 |
775.42 |
45/4.53 |
7/3.02 |
36.24 |
2009 |
393 |
2402 |
170.71 |
0.03994 |
1431 |
725.10 |
91.87 |
816.97 |
54/4.14 |
19/2.48 |
37.24 |
2019 |
719 |
2738 |
218.24 |
0.04013 |
1510.5 |
765.35 |
52.90 |
818.25 |
45/4.65 |
7/3.10 |
37.20 |
2120 |
414 |
2534 |
177.89 |
0.03784 |
1510.5 |
765.35 |
96.84 |
862.19 |
54/4.25 |
19/2.55 |
38.25 |
2131 |
759 |
2890 |
230.20 |
0.03802 |
1590 |
805.68 |
55.48 |
861.16 |
45/4.77 |
7/3.18 |
38.16 |
2232 |
435 |
2667 |
187.02 |
0.03595 |
1590 |
805.68 |
102.13 |
907.81 |
54/4.36 |
19/2.62 |
39.26 |
2243 |
799 |
3042 |
242.55 |
0.03613 |
80 |
40.52 |
14.13 |
54.65 |
8/2.54 |
1/4.24 |
9.32 |
112 |
110 |
222 |
23.60 |
0.7115 |
101.8 |
51.61 |
30.06 |
81.67 |
12/2.34 |
7/2.34 |
11.71 |
143 |
235 |
378 |
41.75 |
0.5613 |
110.8 |
56.13 |
32.77 |
88.90 |
12/2.44 |
7/2.44 |
12.22 |
156 |
256 |
412 |
51.25 |
0.5161 |
134.6 |
68.19 |
39.81 |
108.00 |
12/2.69 |
7/2.69 |
13.46 |
189 |
311 |
500 |
61.70 |
0.4248 |
159 |
80.58 |
46.97 |
127.55 |
12/2.92 |
7/2.92 |
14.63 |
223 |
367 |
590 |
72.55 |
0.3595 |
176.9 |
89.48 |
52.19 |
141.67 |
12/3.08 |
7/3.08 |
15.42 |
248 |
409 |
657 |
78.50 |
0.3237 |
190.8 |
96.71 |
56.39 |
153.10 |
12/3.20 |
7/3.20 |
16.03 |
268 |
441 |
709 |
84.80 |
0.2995 |
203.2 |
102.97 |
91.87 |
194.84 |
16/2.86 |
19/2.48 |
18.14 |
285 |
722 |
1007 |
128.80 |
0.2813 |
211.8 |
107.10 |
62.45 |
169.55 |
12/3.37 |
7/3.37 |
16.84 |
297 |
488 |
785 |
93.90 |
- Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
- No way to save money! Moreover, the signal to you there, almost all attenuation finished.
- Q: Apple 6splus charge may not support this accessories how to do more
- 5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
- Q: Apple phone display cable or accessories not certified how to do
- Reply 3 # shops always have the door, and the door must be adjacent to the outdoor channel. Outdoor channel is public space! So the shop should be able to find the wiring channel. You have not encountered the situation, the map stickers out to see it?
- Q: What is the difference between wires and cables?
- The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
- Q: IPhone mobile phone data cable can not charge the power, the above shows the cable or accessories not certified can not work with the iPhone,
- Not allowed to slot the proposal with PVC gusset which is only 1 cm thick only open protective layer on it! The water pipe is not enough unless you have a thickened wall outside the decoration.
- Q: Apple mobile phone does not support this charge when charging this thing how to charge
- Just show that the sound is still in the host, must be an external sound, your computer monitor can sound it? Not to sound - Bao Haiping studio
- Q: What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
- Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria.............................................
- Q: How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q: If you want to sell wire and cable, then what to do in advance to detect? The The The The The
- Wire diameter, conductor resistance, insulation diameter, the thickness of the thinnest insulation,
- Q: What are the T and T, s of the wire and cable test type?
- The expression is not very clear, it should be said to wear a tube, if a single wear on the line 100. Outside diameter 60mm.
Send your message to us
Cable Conductor HS137
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5mt m.t.
- Supply Capability:
- 40000mts/year m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords