Grade 4245 is specially used for 10KV below aerial hanging power cable, it is composed by 90% silane crosslinkable low density polyethylene (compound A) and 10% black catalyst (compound B). The product’s major characteristics are

◆Outstanding anti-ageing property

◆Low heat shrinkage rate

◆wild processing temperature, easy processing technique and convenient handling

◆Suitable for tubing style extrusion mould.

Standard

After crosslinked in the tepid water, the cable made from the product grade 4245 can comply with the standard of IEC60502-2004, GB/T14049-2008

Main Properties & Typical Values

Test Items

Unit

Test Method

Standard

Typical value

Tensile strength

MPa

GB/T1040.3

≥13.5

19.6

Elongation at break

%

GB/T1040.3

≥300

480

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change      

Maximum elongation at break change

%

%

GB/T8815

±20

±20

8.9

6.7

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load      

Maximum permanent elongation change after cooled

%

%

GB/T2951

≤80

≤5

48

4

Impact brittle temp. (-76℃)  

Impact brittle

Failure no.

GB/T5470

≤15/30

Pass*

Dielectric Strength

MV/m

GB/T1408.1

≥30

39*

Dielectric loss factor 50Hz, 20℃

--

GB/T1409

≤1×10-4

3×10-4*

Dielectric constant 50Hz, 20℃

--

GB/T1409

≤2.35

2.3*

Volume resistance (20℃)

Ω·m

GB/T1410

≥1.0×1014

5×1014*

Pressure crack test F50

hr

GB/T2951

1000

Pass*

Artificial atmosphere ageing properties:

Ageing After 42days,

Maximum tensile strength change      

Maximum elongation at break change

Ageing after 42days vs. after 21days

Maximum tensile strength change      

Maximum elongation at break change

%

%

%

%

GB/T14049

±30

±30

±15

±15

-17

-26

-8

-12

Typical values were tested on the sample strip by squeezing film extrusion after mixing compound of A & B(at percentage of 90:10) and be boiled in hot water at 90℃ for four hours.

*Especially, these typical values were tested by press moulding sample (A and B mixed at percentage of 90:10), under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for four hours.

Recommended Processing Technique

1.   Extrusion Equipment

Most extruders for PVC and PE suit for 4245

The recommended equipment and processing technique is as following.

Ratio of length and diameter                    18—25:1

Diameter                                                 45—120mm

Ratio of compressing                              1.5—3.5

Ratio of elongation                                  1:1.0—1:1.5

Filtering mesh                                         40/60/40

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should be based on different equipment and pressing conditions, reference settings are as following:

Feeding Section(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

135~155

155~170

170~180

180~200


Die head setting:
Tubing extrusion style is recommended.

   

3.   Crosslink

After extrusion and cooling, the cable can be crosslinked by immersed in hot water (90℃) or exposed in low pressure vapour. The time required for crosslink is based on the thickness of the insulation and the coil size, the thicker the insulation and the greater the coil size, the longer the crosslink time required. The crosslink time can be calculated according to the equation of 4hr/mm for 90℃.


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
There must be no room for consultation I did not have to do for seven years lazy they want to do nothing irresponsible
Q: Engineering materials inspection, all types of cable wires should be issued a test report?
You look at your TV behind the interface dvd are generally with the color of the port (green red and blue) interface you dvd the best copy of the flowers deduction ditch dumplings evil spear that interface on the LCD TV certainly with that color interface so that your set-top box Then the av interface (yellow) video port on the line there is a way set-top box with a terminal is the same as the mouse with the same interface with the mouse with the video port plus two voice interface on the line that is better than the av interface can also solve the problem LCD TV certainly Will take that interface you look at the set-top box and dvd have any different interface on the use of the impossible can not only two mouth it (yellow interface) and 40-inch LCD TV is generally high-end are generally two An av channel input you are inserted two lines are also ah
Q: Apple phone display cable or accessories not certified how to do
Indicating that your Apple data cable is not original, no effect, re-plug the general and you can use the.
Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
Directly to find Dell customer service bar, the general warranty period are free replacement, unless the insurance of the. You can extend the warranty period, it seems you like to do the experiment.
Q: Wire and cable CCC product consistency is what
Wire of course, is to use a good slightly, the first life, ah, can not buy cheap because of cheap, like China's top ten brands to buy the brand on the purchase of these brands I feel very good ah, Po Sheng , Luneng Taishan, Far East, Shenghua cable, on the up, prosperous photoelectric, Nexans Nexans these brands of wire is still very good. The landlord you can go to the above to learn more detailed information ah, the top ten wire brand is very detailed, the landlord can understand very clearly, the above brand is very good, my father last time to go above to see, and then buy
Q: Apple mobile phone does not support this charge when charging this thing how to charge
I use the TV as a computer screen, connect the HD line, how no sound
Q: Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q: What is the warranty period for wire and cable?
Direct selection of reton's 32-port digital KVM, model is: KS-2032C. Fast transmission, wiring is simple. Want to know the price to ask their website on it.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords