Low Carbon Steel Wire For Armouring Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5mts m.t.
- Supply Capability:
- 3000mt/Month m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery of Low Carbon Steel Wire For Armouring Cable
Packaging Detail: | 1) By coil: coil weight from 50kg-800kg 2) By plastic reel: each reel is about 25kgs to 40kgs 3) Coils with steel hook and pallets |
Delivery Detail: | 3 or 4 weeks after the confirmation of the order |
Specifications of Low Carbon Steel Wire For Armouring Cable
1 used for fencing and armoured cable
2 diameter:0.3mm-6.0mm
3tensile strength:340-550mpa
1 Standard: BS 443, BS 1442(EN10244-2&EN10257-1)
2 Diameters: from 0.2mm-6.0mm
Raw materials of Low Carbon Steel Wire For Armouring Cable
A, wire rod: 1006, 1008,1018, Q195,etc
B, Zinc with 99.995 purity.
4 Diameter tolerance:+/-0.01mm-0.07mm
5 Zinc coating: 35g-275g/m2
Size mm | Zinc coating min/m2 | ||
A1 | A2 | ||
0.80-1.00 |
150 |
120 | |
1.00-1.20 |
180 |
150 | |
1.20-1.40 |
200 |
150 | |
1.40-1.60 |
220 |
150 | |
1.60-1.80 |
220 |
180 | |
1.80-2.20 |
240 |
190 | |
2.20-2.50 |
260 |
210 | |
2.50-3.00 |
270 |
240 | |
6 Torsion Test: 15 turns-45 turns
7 Tensile Strength:
Size mm |
Tensile strength MPA |
0.80-3.50 |
340-550 |
8 Elongations: 10%min
9 Packing:
1) By coil: coil weight from 50kg-800kg
2) By plastic reel: each reel is about 25kgs to 40kgs
3) Coils with steel hook and pallets
10 Usage: Mainly used on armoring cable.
- Q: The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
- What do you want to do? Do network cabling buried? Or in the building after the tube?
- Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
- According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
- Q: Apple mobile phone does not support this charge when charging this thing how to charge
- I use the TV as a computer screen, connect the HD line, how no sound
- Q: Wire and cable model ZD what does it mean
- Put the water clean, with a table to measure the insulation resistance between the lines, as long as no less than 1.5-2 can.
- Q: What are the varieties of wire and cable (detailed point)
- (The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
- Q: Why does the bird stand on the wire without anything, but if people touch it,
- Please provide air-conditioned three-leg socket photo, because you said "open inside is 2.5 square line ~ is a separate line ~" is not very understanding.
- Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
- Multi-core cable should be cable number, if not, should first use the table to find and put on the line with the tube.
- Q: If you want to sell wire and cable, then what to do in advance to detect? The The The The The
- Wire diameter, conductor resistance, insulation diameter, the thickness of the thinnest insulation,
- Q: What are the T and T, s of the wire and cable test type?
- May be charging head of the problem, the line may also be a problem. If the warranty can be free for the change.
- Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
- Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
1. Manufacturer Overview
Location | Hebei, China |
Year Established | 2002 |
Annual Output Value | USD10,000,000.00 |
Main Markets | Southeast Asia;Mid East;Domestic Market |
Company Certifications | ISO9001-2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin |
Export Percentage | 70% - 80% |
No.of Employees in Trade Department | 50 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 8,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range | High; Average |
Send your message to us
Low Carbon Steel Wire For Armouring Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5mts m.t.
- Supply Capability:
- 3000mt/Month m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords