• Chemical Pump for Hot Temperature Food Oil System 1
  • Chemical Pump for Hot Temperature Food Oil System 2
  • Chemical Pump for Hot Temperature Food Oil System 3
Chemical Pump for Hot Temperature Food Oil

Chemical Pump for Hot Temperature Food Oil

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                   Chemical Pump for Hot Temperature Food Oil

1.Structure of Chemical Pump Description

Chemical Pumpis used in transporting high temperature liquid without solid particles.The temperature is not higher than 370 °C.This pump is proper in machinery manufacturing, food processing, medicine making and the circling system for oil supplying of the hot oil boiler, the circling system of the heating installation.

 

2.Main Features of the Chemical Pump

•Reached JB/JQ20104-1998 standards
•Oil temperature can reach to 200degre. 
•SS304 material 
•Good quality

3.Chemical Pump images

Chemical Pump for Hot Temperature Food Oil

 

4.Chemical Pump Specification

 

Chemical Pump for Hot Temperature Food Oil 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: What is a water pump coupling device?
Advantages of water pump coupling device:1. automatic coupling device, easy installation and maintenance. In the absence of automatic coupling device, fixed installation, such as water pump failure, maintenance personnel need to unscrew screws, lifting pumps for maintenance, or with other small pumps pumping water perfect maintenance,If the water is dirty, it is difficult for people to get down, when the inspection and repair encountered great difficulties. But it is equipped with GAK submersible sewage pumpAfter the automatic coupling device needs lifting, the person can directly lift the water pump without the need to screw the screw into the waterAfter graduation, down the guide rail, you can realize the sealing of water pump and pipeline, so as to make the pump run normally. Small sewage pumps are freeInstallation, large sewage pumps are generally equipped with automatic coupling device, automatic installation, installation and maintenance is very convenient.
Q: What are the causes of pump shock?
6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
Q: The distance from the pump button to the ground
A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q: Why can't the inlet of centrifugal pump be negative pressure?
Therefore, the centrifugal pump inlet pressure can be negative, and negative number, should be used to pump cavitation margin and liquid saturated steam pressure parameters to specific calculation. Sometimes, the liquid saturated steam conveying pressure is very high, such as the 9 m water column, then the minimum pressure of the pump inlet should be equal to 4+9=13 meters, the atmospheric pressure is higher than 3 meters, not only for negative pressure, even higher than the atmospheric pressure to work properly.
Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
Q: Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q: What are the main performance parameters of the pump?
RPM revolutions per minute. In N, the unit is R / minThe power delivered by the shaft power prime mover to the pump shaft. In P, the unit is kW.The ratio of useful power to shaft power of an efficient pump. With ETA said. It is an indicator of the degree of perfection of the pump in terms of hydraulic power
Q: Why is the sewage pump device coupler?
2. automatic coupling device of the sewage pump coupling device has compact structure and small occupation area. Because the sewage pump is submerged, it can be installed directly in the sewage tank, and no special pump room is needed to install the pump and pump. It can save a lot of land and infrastructure costs.
Q: What is the cause of the damage of pump bearings?
In high-speed equipment, the most likely damage to bearings is high temperature.