Basic tech datasheet
UPS Model | EX1K | T1K | EX2K | T2K | EX3K | T3K | |
Capacity | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | ||||
Input | Voltage | (115~300) VAC | |||||
Frequency | 46~54Hz/56~64Hz (Adjustable via LCD panel) | ||||||
Output | Voltage | 220/230/240 (1±1%) VAC (Adjustable via LCD panel) | |||||
Frequency | 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%) | ||||||
Output Wave Form | Sine Wave | ||||||
Back-up Time | Full Load | ≥5′ | ≥9′ |
| ≥5′ |
| |
Half Load | ≥14′ | ≥21′ | ≥15′ | ||||
Battery Nominal DC Voltage | 36VDC | 96VDC | |||||
Transfer Time | 0ms | ||||||
Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms | ||||||
Communications | RS-232+Intelligent Slot | ||||||
Environment | Temperature | 0C~40C | |||||
Humidity | 15%~90% | ||||||
Dimensions (W*D*H)mm | 400*145*220 | 460*192*348 | 460*392*348 |
- Q: How many power illuminator can 5Kva 36V transformer drive?
- By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
- Q: Why should lighting transformers be used in factories and mines?
- There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- No, the zero line of the transformer doesn't go through the zero line of the transformer. It is a star connection, and the center point is zero line
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
- Q: How is the lighting power of the 380V transformer calculated?
- The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
- Q: Power and lighting transformers, lighting quality will be affected much?
- First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
- Q: What's the function of the lighting transformer?
- Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS with PFC Function
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords