Online UPS 1KVA-200KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 10000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Model | 5K-LED
| 6K-LED
| 10K-LED
| 3C20KS-LED
| HT-10-80KS | H-100-200KS | SURTD5000XLI | SURT6000XLI
| SURT8000XLI
| SURT10000XLI
|
| ||||||||||
5KVA | 6KVA | 10KVA | 20KVA | 10-80KVA | 100-200KVA | 5KVA | 6 KVA | 8 KVA | 10 KVA |
| |||||||||||
Pure sine wave dual conversion on-line | |||||||||||||||||||||
Phase | Three phase+N+G | ||||||||||||||||||||
Voltage | 380V±25% | ||||||||||||||||||||
Frequency | 50HZ±10% | ||||||||||||||||||||
Rated DC voltage | 360Vdc | ||||||||||||||||||||
floating voltage | 405Vdc | ||||||||||||||||||||
Cut-off voltage | 315Vdc | ||||||||||||||||||||
charging time | charge to 90% in 8 hours | ||||||||||||||||||||
Phase | Three phase+N+G | ||||||||||||||||||||
Voltage | 380Vac±2%( stable load), 380Vac±5%( fluctuant load) | ||||||||||||||||||||
Frequency | 50Hz±0.5%(On battery) | ||||||||||||||||||||
Power factor | 0.8 | ||||||||||||||||||||
Wave-form | Sine wave | ||||||||||||||||||||
Total Voltage harmonics distortion | Linear load<3%; non-linear load <5% | ||||||||||||||||||||
Output voltage transient characteristic | (Load abrupt change From 0 to 100%) | ||||||||||||||||||||
Transient response time | <20ms | ||||||||||||||||||||
Crest factor | 3:1 | ||||||||||||||||||||
Overload protection | >125%,1min;>150%,200ms | ||||||||||||||||||||
Full load efficiency | ≥90% | ||||||||||||||||||||
Transfer time | 0ms | ||||||||||||||||||||
Protection | (Overload, over charge and over discharge; phase error, out the range of voltage and frequency, over current, short circiut, over temperature ect.) | ||||||||||||||||||||
Display | LCD and LED indicator | ||||||||||||||||||||
Communication | RS232 interface and SNMP card(optional) | ||||||||||||||||||||
Environment temperature | -5~40°C | ||||||||||||||||||||
Relative ambient humidity | 20~95% (Non-condensing) | ||||||||||||||||||||
Altitude | <1500m,1% rated capacity decrease against rised 100m | ||||||||||||||||||||
Cooling method | Forced air-cooling with temperature control | ||||||||||||||||||||
Surge protection | 10/700Us,5KV ;8/20Us,20KA | ||||||||||||||||||||
Safety rate | IP21 | ||||||||||||||||||||
Noise(dB) | <55dB | <65dB | |||||||||||||||||||
450*770*1000 | 700*853*1600 | 1070*900*1630 | 1390*960*1800 | ||||||||||||||||||
227 | 270 | 315 | 377 | 475 | 547 | 950 | 1000 |
|
|
| |||||||||||
- Q: What transformer can be used in a safety voltage lighting transformer?
- An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- The key is that the 220V terminals and 0 can not provide 1000VA capacity?
- Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
- 380V-220V/36V transformers, commonly known as safety transformers or line transformers, are mainly used for lighting in shop equipment and mobile lighting for inspection and maintenance. Their power is 50W, 100W, 200W, 300W., and their line size is determined by power!
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: The difference between lighting transformers and control transformers
- A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
- Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
- Q: How is the lighting power of the 380V transformer calculated?
- The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- 500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
1. Manufacturer Overview
Location | Guangdong,China (Mainland) |
Year Established | 2000 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 10.00% North America 10.00% South America 10.00% Southeast Asia 10.00% Mid East 10.00% Eastern Asia 10.00% Africa 5.00% Eastern Europe 5.00% Western Europe 5.00% Central America 5.00% Northern Europe 5.00% Oceania 5.00% Southern Europe 5.00% South Asia 5.00% Domestic Market |
Company Certifications | ISO 9001:2000;ISO 14001:2004 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Guangzhou |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS 1KVA-200KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 10000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords