Online UPS 1KVA-200KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 10000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Model | 5K-LED
| 6K-LED
| 10K-LED
| 3C20KS-LED
| HT-10-80KS | H-100-200KS | SURTD5000XLI | SURT6000XLI
| SURT8000XLI
| SURT10000XLI
|
| ||||||||||
5KVA | 6KVA | 10KVA | 20KVA | 10-80KVA | 100-200KVA | 5KVA | 6 KVA | 8 KVA | 10 KVA |
| |||||||||||
Pure sine wave dual conversion on-line | |||||||||||||||||||||
Phase | Three phase+N+G | ||||||||||||||||||||
Voltage | 380V±25% | ||||||||||||||||||||
Frequency | 50HZ±10% | ||||||||||||||||||||
Rated DC voltage | 360Vdc | ||||||||||||||||||||
floating voltage | 405Vdc | ||||||||||||||||||||
Cut-off voltage | 315Vdc | ||||||||||||||||||||
charging time | charge to 90% in 8 hours | ||||||||||||||||||||
Phase | Three phase+N+G | ||||||||||||||||||||
Voltage | 380Vac±2%( stable load), 380Vac±5%( fluctuant load) | ||||||||||||||||||||
Frequency | 50Hz±0.5%(On battery) | ||||||||||||||||||||
Power factor | 0.8 | ||||||||||||||||||||
Wave-form | Sine wave | ||||||||||||||||||||
Total Voltage harmonics distortion | Linear load<3%; non-linear load <5% | ||||||||||||||||||||
Output voltage transient characteristic | (Load abrupt change From 0 to 100%) | ||||||||||||||||||||
Transient response time | <20ms | ||||||||||||||||||||
Crest factor | 3:1 | ||||||||||||||||||||
Overload protection | >125%,1min;>150%,200ms | ||||||||||||||||||||
Full load efficiency | ≥90% | ||||||||||||||||||||
Transfer time | 0ms | ||||||||||||||||||||
Protection | (Overload, over charge and over discharge; phase error, out the range of voltage and frequency, over current, short circiut, over temperature ect.) | ||||||||||||||||||||
Display | LCD and LED indicator | ||||||||||||||||||||
Communication | RS232 interface and SNMP card(optional) | ||||||||||||||||||||
Environment temperature | -5~40°C | ||||||||||||||||||||
Relative ambient humidity | 20~95% (Non-condensing) | ||||||||||||||||||||
Altitude | <1500m,1% rated capacity decrease against rised 100m | ||||||||||||||||||||
Cooling method | Forced air-cooling with temperature control | ||||||||||||||||||||
Surge protection | 10/700Us,5KV ;8/20Us,20KA | ||||||||||||||||||||
Safety rate | IP21 | ||||||||||||||||||||
Noise(dB) | <55dB | <65dB | |||||||||||||||||||
450*770*1000 | 700*853*1600 | 1070*900*1630 | 1390*960*1800 | ||||||||||||||||||
227 | 270 | 315 | 377 | 475 | 547 | 950 | 1000 |
|
|
| |||||||||||
- Q: What transformer can be used in a safety voltage lighting transformer?
- Early European countries used in the power industry, widely used in the electronic industry or industrial and mining enterprises, machine tools and machinery equipment general circuit control power supply, safety lighting and indicator light power supply.
- Q: Why is the two side of the lighting transformer grounded?
- Today's lighting products, regardless of the control system or the electronic power system itself, contain many semiconductorsComponents such as rectifier diodes, transistors, integrated circuits, LED, and so on. Semiconductor components are susceptible to staticElectrical damage, the two side of the power transformer grounding, help to produce a variety of factors, high pressure, residual static electricityDrain to avoid static electricity on the main circuit, to ensure product life.
- Q: Why is elevator lighting transformer installed?
- 1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- Power lines and lighting lines are connected to the same transformer, without affecting the use of a transformer power users, lighting and power are connected together.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- A set of coils in a autotransformer having one tap that does not function as a barrier. Or, the two sets of coils are attached.
- Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- 220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
- Q: Power and lighting transformers, lighting quality will be affected much?
- The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
1. Manufacturer Overview
Location | Guangdong,China (Mainland) |
Year Established | 2000 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 10.00% North America 10.00% South America 10.00% Southeast Asia 10.00% Mid East 10.00% Eastern Asia 10.00% Africa 5.00% Eastern Europe 5.00% Western Europe 5.00% Central America 5.00% Northern Europe 5.00% Oceania 5.00% Southern Europe 5.00% South Asia 5.00% Domestic Market |
Company Certifications | ISO 9001:2000;ISO 14001:2004 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Guangzhou |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS 1KVA-200KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 10000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords