The HF33 20-80K series UPS is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. HF33 20-80K series UPS provide customers safe and sound power supply.
Excellent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter
larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can
help to increase the protection level in industrial environment and safeguard the ups security when operation in bad environment.
N+X parallel redundancy (battery share in the parallel mode
The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the
system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS
in the system. The bigger the number of X is, the higher the reliability of the system.The advanced controlling strategy decrease customer's investment by sharing battery group in the parallel redundancy mode.
Intelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter, and provide
the optimum charging modes in different environment, types and amounts of cells, and the using condition of the battery. The
scientific charging mode extends the battery's lifetime. The optional addition to charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization of remote
management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the power loss of UPS.Th factor that the technology of IGBT FM intelligent rectifier and inverter is used , the input power factor is as high as 0.99, and
the input current harmonic wave is as low as 3%,which makes the output voltage electric property more extraordinary.Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1 minute in load of 125-150%. It also has the output short circuit protection capability.
MODEL | HF 3320L | HF 3330L | HF 3340L | HF 3360L | HF 3380L |
Rated Power | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW |
INPUT | |||||
Voltage | 380/400/415VAC(-45%~+25%) | ||||
Frequency | 50/60Hz | ||||
Phase | 3Ph+N+G | ||||
Power Factor | >0.99 | ||||
BYPASS | |||||
Voltage | 380/400/415VAC(-15%~+15%) | ||||
Phase | 3Ph+N | ||||
Frequency | 50/60Hz | ||||
Overload Capability | <150%, normally running | ||||
BATTERY | |||||
Battery Voltage | 336/360/384VDC | ||||
Charging Current | 1-10A(setting by battery capacity) | ||||
OUTPUT | |||||
Phase | 3Ph+N | ||||
Voltage | 380/400/415VAC±1% | ||||
Frequency | 50/60Hz | ||||
Power Factor | 0.8 | ||||
THD | <2%(linear load); <4%(non-linear load) | ||||
Overload Capability | <105% normally running;105%-125% 10min; 125%-150% 1min; 150% 1ms | ||||
Waveform | Pure Sine Wave | ||||
Transfer Time | <10ms | ||||
SYSTEM | |||||
Efficiency | >93% | ||||
Cooling | Fan Cooling | ||||
Communication Interface | RS232,RS485,SNMP card, Dry Contact | ||||
Display | LCD+LED | ||||
Operating Temperature | 0-40℃ | ||||
Humidity | 0-95% non-condensing | ||||
Altitude | <4000m(derated 1% per 100m above 2000m) | ||||
Noise Level | <50dB | <60dB | <65dB | ||
Protection Level | IP20 | ||||
Storage Temperature | -25℃~55℃ | ||||
Dimension(W×D×H mm) | 420×646×956 | 470×714×1160 | 600×800×1850 | ||
Weight(Kg) | 80 | 120 | 120 | 282 | 306 |
Specification is subject to change without prior notice. |
- Q: How to select the UPS power supply
- Multi machine power supplies are available for each other, and N is available in M (N, M for digital). The problem of parallel use of UPS will be involved in multi machine power supply. Because the UPS parallel power supply phase of each machine must agree on this point, the strategy is different, is common to a table clock or electric is synchronized, but when the "command" fault, transfer technology, operation command (set), great the differences between different products; another is a "foreign" recognition of UPS (electric or other UPS) phase function, but has a greater impact on the system reliability sampling scheme.
- Q: What are the UPS power supplies and its uses and features?
- UPS is divided into three major categories: backup, online and online;The US is the most commonly used backup UPS, such as the four HO series and SD series, it has automatic voltage regulator, power protection UPS the most basic and most important function, although the general conversion period of about 10ms, inverter output AC square wave and non sine wave, but due to the simple structure has the advantages of low cost, high reliability, so it is widely used in computer peripherals, POS, machine etc.;The on-line UPS structure is complex, but the perfect performance, can solve the problem of power supply, such as the four PS series, its remarkable characteristic is to continue zero interrupt output pure sine wave AC power supply, can solve all the problems of the peak surge, frequency drift; due to the need for greater investment, usually in the key equipment and network center the electric power demanding environment application;The other four, APC and other manufacturers also provides online interactive UPS, compared with the backup, online interactive with the function of filtering, anti electrical interference ability is very strong, the conversion time is less than 4ms, the inverter output is analog sine wave, so can be equipped with servers, routers and other network devices, or in a relatively harsh environment of power area; especially the four MD series UPS, the price is far lower than the line, should be a better choice to recommend to the user.
- Q: If possible, help to explain a little more about the UPS knowledge, thank you..
- UPS (Uninterruptible, Power, System), that is, uninterruptible power supply, is a kind of energy storage device, inverter as the main component of constant voltage constant frequency uninterruptible power supply. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately built-in battery power supply to 220V alternating current to the load through the method of inverse transformation, the load to maintain normal working and protect the load of software and hardware is not damaged.
- Q: What does "UPS" and "DPU" mean in power plants?
- UPS (Uninterruptible, Power, System), that is, uninterruptible power supply, is a kind of energy storage device, inverter as the main component of constant voltage constant frequency uninterruptible power supply. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices usually provide protection against too large voltages and too low voltages.
- Q: What is the name of the device that provides the server with power?
- The US is the most commonly used backup UPS, such as the four HO series and SD series, it has automatic voltage regulator, power protection UPS the most basic and most important function, although the general conversion period of about 10ms, inverter output AC square wave and non sine wave, but due to the simple structure has the advantages of low cost, high reliability, so it is widely used in computer peripherals, POS, machine etc.;The on-line UPS structure is complex, but the perfect performance, can solve the problem of power supply, such as the four PS series, its remarkable characteristic is to continue zero interrupt output pure sine wave AC power supply, can solve all the problems of the peak surge, frequency drift; due to the need for greater investment, usually in the key equipment and network center the electric power demanding environment application;
- Q: APC UPS power can not boot, what is the reason?
- APC RT3000UXICH DC is 192V, this must be wrong. First, make sure the input plug is power down Then boot, then press the boot button for more than 3 seconds, heard a sound, then let go, you try again
- Q: What server UPS power line?
- To configure the appropriate UPS power for your server, it is recommended that you understand the following:1. what is the number and total power of the server?2. what is the required UPS power supply time?Only in this way can I know how much UPS power and batteries are allocated to the server. As for the brand, the domestic can choose EAST, foreign can choose APC, Emerson, but foreign brands to be partial expensive, but after-sales service speed than domestic slow. Therefore, after consideration with after-sales protection, the choice of domestic brands more appropriate
- Q: Listen to the market vendors themselves, such as C3KS, the actual only about 2K more than a day, is how?
- Performance parameter. UPS uninterruptible power supply as a protective power supply equipment, its performance parameters are of great significance, should be our choice when considering the key. The wide input voltage range indicates that the utilization capacity of the power supply is strong, and the output voltage and frequency range are small, which indicates that the regulation capacity of the power supply is strong and the output is stable. The waveform distortion rate is used to measure the stability of the output voltage waveform, while the voltage stability indicates the stability of the output voltage when the Santak UPS power is suddenly switched from zero load to full load.
- Q: How does PLC use UPS?
- UPS is an uninterruptible power supply, it is the battery (more than lead-acid battery maintenance) connected with the host, through the host, inverter and other circuit modules to convert DC to urban electricity system equipment. The utility model is mainly used for providing stable and uninterrupted power supply for a single computer, a computer network system or other power electronic equipment, such as an electromagnetic valve, a pressure transmitter, etc.. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS immediately DC battery energy conversion method by zero switching inverter continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices are usually protected against high voltage or low voltage.And PLC connection to see the wiring requirements.
- Q: What is the difference between a UPS power supply and a general power supply?
- It is working in the electric machine, the electric AC inverter, and stored in their own power, once to stop power supply, it can provide power, using electrical equipment to maintain a working time, holding time may be 10 minutes, half an hour, the delay time of general battery capacity. Continuous - power regulator, purification to eliminate the power fluctuations and pollution - battery management function, prolong the service life of battery - intelligent monitoring function: to effectively solve the power supply maintenance function high reliability uninterruptible power supply, ensure the power of the
Send your message to us
Online UPS 40KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords