Aluminum Air Grille  600×300 (mm) / 600×600 (mm)

Aluminum Air Grille 600×300 (mm) / 600×600 (mm)

Ref Price:
get latest price
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
500 m²
Supply Capability:
50000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Aluminum Air Grille

Dimension: 600×300 (mm) / 600×600 (mm)

 

Characteristics

The aluminium air grille is designed to deliver a large constant rate of air-flow to a computer/equipment room.The rate of air-flow to the room is dependent upon the pressure within the underfloor plenum,and can be easily adjusted when the air grille is fitted with a damper.The air grille has a natural anodized aluminium finish,which blends well with high pressure laminate panel finish.


Q:How is the floor of the anti-static floor?
Anti-static floor (including ceramic anti-static floor) in the laying, be sure to carry out anti-static grounding and then protect the resistance box, so as to play the effect of anti-static effect. In the anti-static grounding process in the ground connection is mainly used for anti-static pad grounding between the socket can be effective in the production work of the human body or pad to the electrostatic discharge to the earth. Antistatic grounding wire is mainly electrostatic grounding wire grounding wire components, including polyurethane straight or slingshot line, in the two ends of the head with suction cups, claws nails, ring terminals, button deduction, alligator clip If you want to achieve a simple ground pad, One end with 10mm universal button to connect table mats or mats, the other end of the connection to the public grounding point, the 10mm buckle precision injection molding, with green and yellow wiring, beautiful and durable. For the Taiwan ground universal grounding wire, often equipped with claw nail-type metal buckle, easy to install directly on the table mat; the other end of the ground wire with a banana plug and alligator clip, easy to insert the grounding socket and directly clamp the ground wire, through the ground The line will work in the static electricity generated by rapid discharge.
Q:What is the effect of static electricity on electronic components?
Electronic components in the actual use, always produce a certain amount of static electricity, which led to a series of problems. Therefore, how to effectively prevent the generation of electronic components static electricity has become one of the hot spots in the field of electronic information industry. In this paper, the principle of static electricity is analyzed, and the harm of static electricity to electronic components is discussed. Finally, the protection measures of electrostatic protection of electronic components are put forward....
Q:We need to renovate the engine room, the general number of space is appropriate?
The general height is ten centimeters, fifteen centimeters, twenty centimeters, twenty five centimeters, thirty centimeters, this height is the height of the ground to the board. Overhead anti-static floor, also known as dissipation-type electrostatic floor. When it is grounded or connected to any lower potential, the charge can be dissipated, characterized by a resistance of 10 to 5 in the order of 10 to 10.
Q:How to lift the UPS static electricity
The UPS is static because the ground is not connected because of the sinking of the socket. The role of anti-static floor is to prevent people walking on the floor when the human body to produce static electricity, and the role of different ground.
Q:Will the security system cabinets can be installed directly on the static floor, do not use the base for the care of the pile of stupid shoes, Please list the relevant specifications, the standard provisions to be explained! Thank you more
Yes. As long as the electrostatic board is made of cement and fireproof material on it
Q:Anti-static activities of the floor by which the map set
I do not know the practice is the standard production standards or construction requirements?
Q:Machine room length 7.6m, width 5.3m, about 40 square meters, the existing grounding copper belt 100m, specifications 3X30MM, insulated helium for the reclamation of the old rush to protect the child 10cm / sets, 100 sets, tin plating busbar 8 * 100 * 400mm, 1 set, lightning down ground, specifications 50mm2,1m, ground terminal, specifications 4 * 40 * 400 + 2000mm flat steel, 1 item. Room electrostatic floor there are others to do we only mine, I would like to ask 1, the room needs to be connected to the number of copper meters? 2, the above products how to do lightning protection grounding specific steps and what to pay attention to. 3, horizontal ground and electrostatic floor between the height of 15cm enough? (Between the ground and the electrostatic floor has a 10cm high trough) is best to give a set of programs, to help me solve the problem to the 100 Thank you more
Weak mine grounding: copper belt laying method There are several cases, 1, if the whole shop is 600 * 600 grid, 40 square will be 140 meters, so the cost is too high, the general project will not do so. 2, you can use the copper machine around the room is about 26 meters, the middle of a thin copper foil instead of doing electrostatic copper network, so a lot of low cost, but also in accordance with the norms to do this is more commonly used method. 3, can also be made "day" field head, so you can save a lot of material costs. Copper tape laying in the vicinity of the electrostatic floor bracket, copper belt and bracket, equipment to make a good connection between. These methods are useful to the project, the specific use of which method, this should be based on the design side or your material engineering offer. Insulators are mainly fixed, insulated copper role, the cost is cheaper. Horizontal ground and electrostatic floor between the helium for the reclamation of the old rush 15cm height enough. The main role of the busbar is to connect all the equipment ground, copper, pooled on the busbar, and then connected to 50 square bus, bus can be connected to the building public ground, the specific needs of how many meters, this should be based on distance. Probably this way. I hope I can help you
Q:How to properly regulate the installation of pvc plastic anti-static floor
Please professional construction team construction is the best!
Q:How to remove the clothes static, so that clothes do not close
After bathing some moisturizing lotion, hands and other exposed parts rubbing treasure, it is impossible to buy a static treasure. OKorder have to sell.
Q:How many anti-static floor with feet and beams
A square anti-static floor, the ratio of feet is 3.5, beam ratio is 5.5, an anti-static floor 0.36 square, calculated down, an anti-static floor foot ratio is 1.26, beam ratio of 1.98, do the project are generally So the ratio, if the wholesale, that ratio will be much less, should be wide floor professional to do the project, so the fight against the attack Jiqiu fluttering Wei Wei two pieces are according to this ratio, in summary, that 100 Block floor, feet to be equipped with 126, beam 198, 396 screws, a beam with 2 screws, and so on

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords