Needle-punched PET/PP Nonwoven Geotextile
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1*20FCL m.t.
- Supply Capability:
- 100 Million M2 Per Year m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Introduction of Needle-punched Nonwoven Geotextile:
Good flexibility, permeability, filtration, separation and easy for construction.
Application of Needle-punched Nonwoven Geotextile:
Geotextile has excellent permeability, acquired, durability, which can be widely used in railway, highway, movement hall, Dams, hydraulic structures, hence hole, coastal shoal, reclamation, environmental protection and other projects. The main products are Synthetic staple fibers needle punched non woven geotextiles and slit and spilt film yarn woven geotextiles.
Technical specification of short fiber Needle-punched Nonwoven geotextile:
No. |
Item |
Specification |
Note | ||||||||||
100 |
150 |
200 |
250 |
300 |
350 |
400 |
450 |
500 |
600 |
800 | |||
1 |
Weight Variation% |
-8 |
-8 |
-8 |
-8 |
-7 |
-7 |
-7 |
-7 |
-6 |
-6 |
-6 |
|
2 |
Thickness mm≥ |
0.9 |
1.3 |
1.7 |
2.1 |
2.4 |
2.7 |
3.0 |
3.3 |
3.6 |
4.1 |
5.0 | |
3 |
Width Variation % |
-0.5 | |||||||||||
4 |
KN/m≥ |
2.5 |
4.5 |
6.5 |
8.0 |
9.5 |
11.0 |
12.5 |
14.0 |
16.0 |
19.0 |
25.0 |
MD and TD |
5 |
Elongation at Break % |
25~100 | |||||||||||
6 |
CBR Mullen Burst Strength KN ≥
|
0.3 |
0.6 |
0.9 |
1.2 |
1.5 |
1.8 |
2.1 |
2.4 |
2.7 |
3.2 |
4.0 |
|
7 |
Sieve Size O90 mm |
0.07~0.2 |
| ||||||||||
8 |
Vertical Permeability Coefficient cm/s |
K×(10ˉ1~10ˉ3) |
K=1.0~9.9 | ||||||||||
9 |
Tear Strength KN≥ |
0.08 |
0.12 |
0.16 |
0.20 |
0.24 |
0.28 |
0.33 |
0.38 |
0.42 |
0.46 |
0.6 |
MD and TD |
- Q: Do you need a cushion on the ground floor?
- As well as the time to build a wooden building with concrete pier, from the ground or contact the ground to do a good job preserving.
- Q: Why do the basics of the cushion waterproofing
- Raft foundation do not do waterproof mainly depends on the design of the groundwater level considerations, calculated if the floor itself to meet the requirements, you can not do, and not rigid to do
- Q: Is it possible to make a waterproof layer
- 1, to do after the dry do, or prone to the phenomenon of wall skin off.
- Q: Is the raft cushion waterproofing full of the cushion?
- The request is full. Raft foundation do not do waterproof mainly depends on the design of the groundwater level considerations, calculated if the floor itself to meet the requirements, you can not do, and not rigid to do.
- Q: Can the floor tiles be removed from the cement mats on the prefabricated board floor?
- Cement cushion as a leveling layer on the floor, not designed to the structure of the load-bearing, the general can be dug, the cushion is generally 3 to 5 cm, chisel in addition to unloading the floor of the heavy objects, chisel in addition to the use of strong vibration Machine or penetrating machine is too large, with a small hammer small chisel, along the horizontal plane horizontal chisel, stripping cement cushion.
- Q: Cushion, waterproof layer construction to do what information
- 3, waterproof layer: In order to prevent the rain into the roof, groundwater into the wall, basement and underground structures, indoor water into the floor and walls and other materials layer.
- Q: Is foam concrete suitable for use as a cushion?
- Inappropriate. Bubble concrete is a new type of energy-saving and environmentally friendly building materials, which are widely used in wall materials, but there are still some defects, such as low strength, cracking, water absorption, as the cushion of its strength is not enough standard.
- Q: What is the waterproof layer and the waterproof cushion in the tile roof?
- Waterproof layer: set in the tile or metal sheet below, from the waterproof, moisture-proof structure of the layer. The waterproof cushion plays an important role in the tile surface, because the "tile" itself can not be counted as a waterproof material, only tile and waterproof cushion combination to form a waterproof fortification.
- Q: How to build a fine stone concrete cushion?
- Reduce ground cracking, plus steel mesh. Reinforced mesh, should be placed in the middle of the concrete, because the protective layer of concrete thick Fang generally only 5CM thickness, so the middle is the best.
- Q: Why calculate the amount of time to count a lot of cushion ah
- In the building construction refers to the base is located below the cushion sometimes also served as grassroots. With the cushion, in the above work is convenient, clean, especially the mold, bar reinforced, pouring concrete and other processes, will not be affected by the basic earth pollution. Set the place where the cushion is generally based, floor, roof (slope) and so on.
1. Manufacturer Overview
Location | Hebei, China |
Year Established | 2004 |
Annual Output Value | Above US$ 100 Million |
Main Markets | Europe; East Asia; America |
Company Certifications | ISO 9001 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qindgao; Tianjin |
Export Percentage | 50% - 100% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | 6 million square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered; Design Service Offered |
Product Price Range |
Send your message to us
Needle-punched PET/PP Nonwoven Geotextile
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1*20FCL m.t.
- Supply Capability:
- 100 Million M2 Per Year m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords