• Natural Curing Silane XLPE Compound for 3KV and Below Cable Wire System 1
Natural Curing Silane XLPE Compound for 3KV and Below Cable Wire

Natural Curing Silane XLPE Compound for 3KV and Below Cable Wire

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000kgs kg/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

Grade 4214N/4244N is sioplas (two steps) natural curing silane XLPE compound, it is composed by compound A and compound B.Compound A is high-quality special polyethylene material with unique grafting process, while compound B adopts the advanced catalyst system. The product can be quickly crosslinked in hot water or after some time exposed in the air, it is suitable for 3kv and below low voltagecable. The major characteristics are

◆Quick crosslinking speed, not necessary be boiled in hot water, simplify the procedure, and improve the production efficiency and cost saving.

◆Non-corrosive to the equipment line, non-corrosive to copper conductor.

◆Less affected by the masterbatch.

Grade 4214N is suitable for the extrusion method of squeezing extrusion,half-tubing extrusion and tubing extrusion; grade 4244N is suitable for tubing extrusion method.

Suitable for small cable with cross sectional area equal to or larger than1.5mm2.

Halogen free, and environment friendly.

Standard

Performance test is in accordance with JB/T 10437-2004 standard. The cable made from the product grade 4214N/4244N can comply with the standard of IEC60502-2004, GB/T12706-2002.

Main Properties & Typical Values

Test items

Test method

Unit

Typical value

4214N

4244N

Tensile strength

GB/T1040.3

MPa

19.8

20.5

Elongation at break

GB/T1040.3

%

502

525

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load

Maximum permanent elongation change after cooled

GB/T2951

%

%

72

4

64

0

Gel content

JB/T 10437

%

65*

72*

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change

Maximum elongation at break change

GB/T8815

%

%

6*

-8*

8*

-6*

Impact brittle temp. (-76℃)

GB/T5470

---

pass

Pass**

Dielectric strength

GB/T1408.1

MV/m

37

35**

Dielectric loss factor 50Hz, 20℃

GB/T1409

---

3.0×10-4

5×10-4**

Dielectric constant 50Hz, 20℃

GB/T1409

---

2.25

2.30**

Volume resistance (20℃)

GB/T1410

Ω.m

2×1014

1×1014**

Typical values were tested on the 1mm sample strip by squeezing film extrusion after mixing compound of A& B (at percentage of 95:5), double-sided exposure in the constant temperature and humidity box (23℃, relative humidity 75%) and measured after 48 hours.

*Especially, these typical values were tested on fully solidified and cured sample (If the sample is not fully cured, it will continue the curing during ageing procedure, and consequently will affect the test result before and after heat ageing).

**Especially, these typical values were tested by press moulding sample under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for one hour.

Recommended Processing Technique

1.   Extrusion Equipment

The product is easy to be plasticized, ordinary PVC-use single screw extruder (length-diameter ratio is 15 to 20) can be used,the equipment requirement is relatively simple screw structure and the flow wayis smooth and no dead end.

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should be based on different equipment and pressing conditions, reference settings are as following:

Grade

Feeding Section

(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

4214N

130~140

150~160

160~170

170~180

4244N

130~140

150~160

160~170

160~170


Die head setting:
4214N is suitable for squeezing extrusion style, half-tubing extrusion style and tubing extrusion style. 4244N is suitable for tubing extrusion method. To produce with tubing extrusion style, the recommended draw ratio is less than 1.2 (4214N) / 1.3(4244N), the greater the draw ratio the greater the thermal shrinkage.

Cooling water temperature: Should not be less than 25℃,gradual cooling water tank is recommended.

Conductor temperature: Appropriate warm-up the copper or aluminium conductor, which can further reduce the heat shrinkage of the insulation and accelerate the cross link speed.

   

Crosslink Speed

For the cable made from this material, the cross link speed has close relation tothe insulation thickness, ambient temperature, environment humidity and coilsize. The thinner and smaller the coil size, the higher temperature and humidity, the shorter the time needed for cross linking. During cold and dry winter season, the crosslink speed in natural environment will be comparatively slow down. To reduce the cross linking time, it is recommended to spray somehot water on the surface of the insulation to accelerate cross link procedure.

Insulation thickness

23℃, humidity 75%

35℃, humidity 60%

90℃ in water

0.9 mm

2-3 days

1-2 days

<30 min

1.4 mm

5-7days

3-4 days

<60 min

1.8 mm

8-10 days

5-7 days

<90 min


Note:The above data were tested on the sample by squeezing film extrusion after mixing compound of A & B (at percentage of 95:5),double-sided exposure in the constant temperature and humidity box;the above value may differ from the actual cross link speed.


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.
Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
A very practical proposal: to your local talent market, a large job fairs, and the best and your professional relevance, to see, look at what positions, pay how? You can also chat with hr, you will understand.
Q: Apple 6splus charge may not support this accessories how to do more
5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
Q: The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
Power lines tied together, usb line bundled together, high and low pressure apart. Tie the tie on the line
Q: Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
casing filled with dry cement, and with a wooden hammer tamping, but a certain idea of security, high pressure line once rammed the skin is too dangerous, should be done before power, you now estimated to have power,
Q: Decoration when the purchase of water pipes, wires and other items included in the account
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q: Wire and cable model ZD what does it mean
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q: Why this cable has not yet been certified
Electromechanical products are usually used to be assembled into parts, multiple parts and then assembled into a single product, the number of products or the number of pieces measured
Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
Multi-core cable should be cable number, if not, should first use the table to find and put on the line with the tube.
Q: What are the T and T, s of the wire and cable test type?
The expression is not very clear, it should be said to wear a tube, if a single wear on the line 100. Outside diameter 60mm.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords