Description

Grade 4214N/4244N is sioplas (two steps) natural curing silane XLPE compound, it is composed by compound A and compound B.Compound A is high-quality special polyethylene material with unique grafting process, while compound B adopts the advanced catalyst system. The product can be quickly crosslinked in hot water or after some time exposed in the air, it is suitable for 3kv and below low voltage cable. The major characteristics are

◆Quick crosslinking speed, not necessary be boiled in hot water, simplify the procedure, and improve the production efficiency and cost saving.

◆Non-corrosive tothe equipment line, non-corrosive to copper conductor.

◆Less affected bythe masterbatch.

Grade 4214N is suitable for the extrusion method of squeezing extrusion,half-tubing extrusion and tubing extrusion; grade 4244N is suitable for tubing extrusion method.

Suitable for small cable with cross sectional area equal to or larger than 1.5mm2.

Halogen free, and environment friendly.

Standard

Performance test is in accordance with JB/T 10437-2004standard. The cable made from the product grade 4214N/4244N can comply with the standard of IEC60502-2004, GB/T12706-2002.

Main Properties & Typical Values

Test items

Test method

Unit

Typical value

4214N

4244N

Tensile strength

GB/T1040.3

MPa

19.8

20.5

Elongation at break

GB/T1040.3

%

502

525

Heat elongation (200±3)℃x15minx0.2MPa)

Maximum elongation change under load

Maximum permanent elongation change after cooled

GB/T2951

%

%

72

4

64

0

Gel content

JB/T 10437

%

65*

72*

Heat ageing properties (Test temperature 135℃, 168hr)

Maximum tensile strength change

Maximum elongation at break change

GB/T8815

%

%

6*

-8*

8*

-6*

Impact brittle temp. (-76℃)

GB/T5470

---

pass

Pass**

Dielectric strength

GB/T1408.1

MV/m

37

35**

Dielectric loss factor 50Hz, 20℃

GB/T1409

---

3.0×10-4

5×10-4**

Dielectric constant 50Hz, 20℃

GB/T1409

---

2.25

2.30**

Volume resistance (20℃)

GB/T1410

Ω.m

2×1014

1×1014**

Typical values were tested on the 1mm sample strip by squeezing film extrusion after mixing compound of A& B (at percentage of 95:5), double-sided exposure in the constant temperature and humidity box (23℃, relative humidity 75%) and measured after 48 hours.

*Especially, these typical values were tested on fully solidified and cured sample (If the sample is not fully cured, it will continue the curing during ageing procedure, and consequently will affect the test result before and after heat ageing).

**Especially, these typical values were tested by press moulding sample under the condition of 180±2 ℃, 15min, and pressure over 15Mpa, then boiled in 90℃ water for one hour.

Recommended Processing Technique

1.   Extrusion Equipment

The product is easy to be plasticized, ordinary PVC-use single screw extruder (length-diameter ratio is 15 to 20) can be used,the equipment requirement is relatively simple screw structure and the flow way is smooth and no dead end.

2.   Extruder processing temperature and other related settings

Temperature Setting:  Specific processing temperature should be based on different equipment and pressing conditions, reference settings are asfollowing:

Grade

Feeding Section

(℃)

Compression Section(℃)

Measurement Section

(℃)

Die head and Mould

(℃)

4214N

130~140

150~160

160~170

170~180

4244N

130~140

150~160

160~170

160~170

Die head setting: 4214N is suitable for squeezing extrusion style, half-tubing extrusion style and tubing extrusion style. 4244N is suitable for tubing extrusion method. To produce with tubing extrusion style, the recommended draw ratio is less than 1.2 (4214N) / 1.3(4244N), the greater the draw ratio the greater the thermal shrinkage.

Cooling water temperature: Should not be less than 25℃, gradual cooling water tank is recommended.

Conductor temperature: Appropriate warm-up the copper or aluminium conductor, which can further reduce the heat shrinkage of the insulation and accelerate the cross link speed.

   

Crosslink Speed

For the cable made from this material, the cross link speed has close relation tothe insulation thickness, ambient temperature, environment humidity and coilsize. The thinner and smaller the coil size, the higher temperature and humidity, the shorter the time needed for cross linking. During cold and dry winter season, the crosslink speed in natural environment will be comparatively slow down. To reduce the cross linking time, it is recommended to spray some hot water on the surface of the insulation to accelerate cross link procedure.

Insulation thickness

23℃, humidity 75%

35℃, humidity 60%

90℃ in water

0.9 mm

2-3 days

1-2 days

<30 min

1.4 mm

5-7days

3-4 days

<60 min

1.8 mm

8-10 days

5-7 days

<90 min


Note:The above data were tested on the sample by squeezing film extrusion after mixing compound of A & B (at percentage of 95:5),double-sided exposure in the constant temperature and humidity box;the above value may differ from the actual cross link speed.


Q:Apple 6splus charge may not support this accessories how to do more
When the lighting circuit and the power circuit shared ladder, BV line is not allowed to put in the ladder, so it is recommended to use the wiring of the lamp ZC-YJV-3 * 2
Q:What are the T and T, s of the wire and cable test type?
The expression is not very clear, it should be said to wear a tube, if a single wear on the line 100. Outside diameter 60mm.
Q:Apple mobile phone does not support this charge when charging this thing how to charge
Charging line and the phone does not match, for the good point of the line just fine
Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:The data line is my online to buy the extension of the line, has been able to use, and today suddenly can not charge the electricity, and pop up the tips, which is why? More
What do you want to do? Do network cabling buried? Or in the building after the tube?
Q:If you want to sell wire and cable, then what to do in advance to detect? The The The The The
Line width, and can not pass the gap between the chip pins, even after, but also because the distance between the wire and the lead is less than the electrical rules specified in the safe distance. In general, the ground can not pass through the gap between the chip pins, go outside or take the gap between the two columns through the gap. The width of the ground wire can also be set appropriately, and the wire is widened by adding a polygon brass cut. The safety distance in the electrical rules defaults to 10 mils, which is relatively small, and the safety distance of the different networks should be set separately as needed.
Q:Wire and cable CCC product consistency is what
PVC line, the market is better with plastic, plastic, . Wantong, etc., if only home improvement, then the brand requirements do not need so high. Small brands are the same, we see the quality. Network cable, then preferred Ann or TCL.
Q:What are the varieties of wire and cable (detailed point)
(The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
Q:Apple phone display cable or accessories not certified how to do
The control cable transfers the electrical energy from the power distribution point to the power supply lines of the various electrical equipment The rated voltage of the power cable is generally 06 / 1kV and above, the control cable is mainly 450 / 750V The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick
Q:Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
The proportion of the cross-sectional area of the cable through the embedded pipe is 20%

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords