Nylon cable Tie HS-250D
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100bags bag
- Supply Capability:
- 100000 bags/year bag/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications of Nylon Cable Tie HS-250
100PCS | ||||||
HS-200D |
8" |
200 |
7.6 |
50 |
120 |
55 |
HS-250D |
10" |
250 |
7.6 |
63 |
120 |
55 |
HS-300D |
11 5/8" |
300 |
7.6 |
82 |
120 |
55 |
HS-350D |
13 3/4" |
350 |
7.6 |
90 |
120 |
55 |
HS-370D |
14 1/2" |
370 |
7.6 |
102 |
120 |
55 |
HS-400D |
15 3/4" |
400 |
7.6 |
105 |
120 |
55 |
HS-450D |
17 3/4" |
450 |
7.6 |
118 |
120 |
55 |
HS-500D |
19 11/16" |
500 |
7.6 |
150 |
120 |
55 |
HS-550D |
21 11/16 |
550 |
7.6 |
160 |
120 |
55 |
HS-430DL |
17 " |
430 |
9 |
112 |
175 |
80 |
HS-550DL |
21 11/16" |
550 |
9 |
160 |
175 |
80 |
HS-650DL |
25 9/16" |
650 |
9 |
190 |
175 |
80 |
HS-760DL |
30" |
760 |
9 |
225 |
175 |
80 |
HS-810DL |
32 |
810 |
9 |
239 |
175 |
80 |
HS-920DL |
36 1/4" |
920 |
9 |
265 |
175 |
80 |
HS-1168DL |
46 |
1168 |
9 |
360 |
175 |
80 |
HS-550FL |
21 11/16" |
550 |
12.7 |
160 |
250 |
114 |
Packing of Nylon Cable Tie HS-250:
As Customer Request
Application fo Nylong Cable Tie HS-250:
Cable Package
- Q: Engineering materials inspection, all types of cable wires should be issued a test report?
- You look at your TV behind the interface dvd are generally with the color of the port (green red and blue) interface you dvd the best copy of the flowers deduction ditch dumplings evil spear that interface on the LCD TV certainly with that color interface so that your set-top box Then the av interface (yellow) video port on the line there is a way set-top box with a terminal is the same as the mouse with the same interface with the mouse with the video port plus two voice interface on the line that is better than the av interface can also solve the problem LCD TV certainly Will take that interface you look at the set-top box and dvd have any different interface on the use of the impossible can not only two mouth it (yellow interface) and 40-inch LCD TV is generally high-end are generally two An av channel input you are inserted two lines are also ah
- Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
- Directly to find Dell customer service bar, the general warranty period are free replacement, unless the insurance of the. You can extend the warranty period, it seems you like to do the experiment.
- Q: Cable a fire line power and why the other did not pick up the line with a pen test also have electricity? Answer detailed point
- Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.
- Q: Wire and cable CCC product consistency is what
- What brand of wire pipe PVC pipe used? Is not in the financial or plastic surgery better ah? Guiqiu we recommend, thank you! What brand of network cable used a good, need double shielded cable, thank you
- Q: Wire and cable: RVFV. : RVFSV. : UTP-CAT5E. : SYV-F-75-5 : RVFSP. : RVSP. : RVFVSP. What is the type of wire? Solve! More
- Pro, please buy in the hardware store turpentine wipe, a bottle of 3.5
- Q: Apple 6 Charging Why always show this cable has not yet been certified
- Set-top box with the AV cable connection: yellow - video, red and white - audio, corresponding to the TV's AV input interface can be connected (do not receive the TV component interface). As for the emergence of partial pink, the possible reasons are: . poor contact. You will re-connect the three-color AV cable to the set-top box, on the TV, to ensure good contact. . cable quality. Three-color AV cable may not be the quality, if you can replace a group of try, or use the DVD and other equipment connected with the TV to test the AV line with or without problems. . TV AV input failure. You can use other video source equipment connected to the TV test, such as: DVD, VCD machines and so on. . set-top box failure. May be set-top box AV output port problems, if there are multiple sets of AV output, you can try other port okay, not the case may be the quality of set-top box, call customer service it.
- Q: What are the varieties of wire and cable (detailed point)
- (The difference between the two cables: WDZ and WDZC are the combustion characteristics of the cable, both halogen-free low smoke flame retardant cable, but the former is a single vertical flame retardant test, which is bundled combustion C class flame retardant Test, but the flame retardant performance requirements are not the same. The meaning of the letter: W refers to the halogen-free; D refers to the low smoke; Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant reference )
- Q: How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q: This cable or accessory has not been certified and may not be able to work with this iphone reliably
- The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
- Q: If you want to sell wire and cable, then what to do in advance to detect? The The The The The
- Wire diameter, conductor resistance, insulation diameter, the thickness of the thinnest insulation,
1. Manufacturer Overview
Location | Guangdong,China |
Year Established | 2003 |
Annual Output Value | Above US$10 Million |
Main Markets | Mid East;Western Europe;North America,South Asia |
Company Certifications | ISO 9001:2008; |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen |
Export Percentage | 0.9 |
No.of Employees in Trade Department | 60 People |
Language Spoken: | English;Chinese; |
b) Factory Information | |
Factory Size: | Above 400,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered;Design Service Offered |
Product Price Range | Average |
Send your message to us
Nylon cable Tie HS-250D
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100bags bag
- Supply Capability:
- 100000 bags/year bag/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords