mn series 220v from 0.4kw to 3.7kw Frequency Inverter
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
SVF-MN
MiniSensorless Vector Frequency Inverter
Voltage and power range:
3phase, 380v: 0.4~5.5kw
3/1 phase, 220v: 0.4~3.7kw
Output frequency range: 0.00Hz-400.00 Hz
TechnicalAdvantage
Control mode
(1) VF control: Multipoint VF curve. This apply to the situation that one frequencyinverter drives multiple motors, such as fan, water pump, engraving machine,injection molding machine etc.
(2) Open-loop vector control: Steady speed with highprecision, wide range of speed governing, as the speed ratio is 1:150 and frequencyis 0.5Hz, we could output 150% rated torque. Good dynamic performance.
TechnicalParameter
Input voltage | Output current (A) | Adopter motor KW | |
SVF-MN0.4S/T2B |
Single or three phase 220V±15% | 2.5 | 0.4 |
SVF-MN0.75S/T2B | 5 | 0.75 | |
SVF-MN1.5S/T2B | 7 | 1.5 | |
SVF-MN2.2S/T2B | 9.6 | 2.2 | |
SVF-MN3.7S/T2B | 17 | 3.7 | |
SVF-MN0.4T4B |
Three phase 380V±15%
| 1.2 | 0.4 |
SVF-MN0.75T4B | 2.5 | 0.75 | |
SVF-MN1.5T4B | 3.7 | 1.5 | |
SVF-MN2.2T4B | 5 | 2.2 | |
SVF-MN3.7T4B | 8.8 | 3.7 | |
SVF-MN5.5T4B | 12.8 | 5.5 | |
SVF-MN7.5T4B | 17 | 7.5 | |
|
Relatedparts
ApplicationFields
SVF-MN series frequencyinverter could be widely used in the industry of food, packing, textile,engraving machines, washing machine, offset machine and rolling door etc.
- Q: What is the difference between variable frequency motor and variable speed motor?
- The variable frequency motor requirements are high, are special motor, so the general motor can not use the inverter to speed. According to the above formula, it can be seen that increasing the frequency, the motor speed will be faster, reduce the frequency of the motor speed is slow, variable frequency motor core is also a special material, because the ferromagnetic material There is a saturation period, to the saturation period, regardless of whether the motor current increases, the motor will not continue to increase the intensity of the magnetic field,
- Q: Is the inverter output current proportional to the output torque?
- When 50HZ or more, the voltage is not increased, the magnetic flux decreases. P = T * n / 9550, if the motor output torque does not change, the current will increase, the motor heat overload
- Q: Yaskawa inverter reported base blockade what is the reason?
- For example, when you stop the inverter, there will be a signal to the inverter, and then the inverter will base block, cut off the output, the motor will no longer work; when you need the inverter work, There is a signal to the inverter, the inverter to cancel the base blockade, it is normal work,
- Q: The notebook power adapter flashes
- The problem is very simple Well, used to know all the notebook Kazakhstan, the adapter has a light above, if it is lit that is the problem of the notebook, the other side of the notebook above also have a power indicator, the notebook above prompted the red, but not Rushed, that is, the problem of the notebook, the computer problem, you directly on the factory is finished, if the insurance, and casually find a place to repair a Kazakhstan, 50-80 yuan if the adapter is bad, buy a generic You can, but also more than 50 points, the last time I bought a bad 58 yuan, ASUS GM, to help people in the end, to give you a shop to buy the adapter, you ask the owner of Kazakhstan to get,
- Q: The Schneider inverter reports the nlp command
- Schneider inverter reported nlp ??? main circuit no electricity 1 re-power up 2 connected to the DC reactor terminals PO, PA / + between the short wiring, the main circuit can not be powered
- Q: What is the difference between AC and DC frequency converters?
- Inverter air conditioner is relatively speaking in terms of ordinary air conditioning, ordinary air conditioning compression motor using AC induction motor, speed unchanged, 50HZ when the speed is about 2880r / min. The inverter air conditioner is the first 220V, 50HZ single-phase AC into three-phase inverter AC (25 ~ 118HZ, 56 ~ 160), the supply of compressors, through the frequency changes to adjust the compressor speed, so that continuous cooling capacity to adapt to air conditioning Load needs. L inverter air conditioner works: inverter air conditioner compressor by the variable frequency motor drag, the power inverter output frequency changes in the alternating current to the motor, so that the motor speed can be based on the needs of indoor cooling and continuous change, the final compressor cooling capacity To achieve continuous changes in the automatic control. In order to meet the continuous changes in the cooling capacity, the refrigeration system uses an electronic expansion valve, the pulse motor switch valve core, rapid control into the evaporator refrigerant flow. Power frequency changes from the inverter to achieve, as shown in Figure 1: 220V, 50HZ of the mains input, the frequency converter A / D AC / DC conversion, D / A inverter, the output frequency required by the three-phase alternating current, Room switching power supply principle is similar.
- Q: Do not the laptop directly connected to the power adapter?
- "Notebook do not power adapter", can only use the internal lithium battery power supply work. It can not directly use 220V AC power supply for it. 1, because the notebook product design power supply standard, is to use the matching power adapter power supply. That is, the power adapter will 220V civilian AC, rectifier filter, and then converted to low-voltage 19V DC, for the notebook to provide power supply;
- Q: On the laptop power adapter problem
- Notebook power on the two specifications, one is 65W, one is 40W, 65W power supply is a discrete graphics notebook, 40W is integrated graphics notebook. Just connected to the use of power, then there is no problem. Just if you laptop battery with the light of the words, plug in the power can not be the same as with the 65W, immediately you can use the boot. Because the current is low, the charging speed is relatively slow. The other will not have any effect
- Q: What is the meaning of the bipolar polarity in the inverter ah There is a +10V signal input is a -10V What is the meaning of ah?
- Analog signal input: Reference setting Input voltage Positive terminal (0 --- 10V)
- Q: How to choose a power adapter
- With the seller to an output 20V ,, 0.5A IBM single hole power adapter
Send your message to us
mn series 220v from 0.4kw to 3.7kw Frequency Inverter
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords