mn series 220v from 0.4kw to 3.7kw Frequency Inverter
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
SVF-MN
MiniSensorless Vector Frequency Inverter
Voltage and power range:
3phase, 380v: 0.4~5.5kw
3/1 phase, 220v: 0.4~3.7kw
Output frequency range: 0.00Hz-400.00 Hz
TechnicalAdvantage
Control mode
(1) VF control: Multipoint VF curve. This apply to the situation that one frequencyinverter drives multiple motors, such as fan, water pump, engraving machine,injection molding machine etc.
(2) Open-loop vector control: Steady speed with highprecision, wide range of speed governing, as the speed ratio is 1:150 and frequencyis 0.5Hz, we could output 150% rated torque. Good dynamic performance.
TechnicalParameter
Input voltage | Output current (A) | Adopter motor KW | |
SVF-MN0.4S/T2B |
Single or three phase 220V±15% | 2.5 | 0.4 |
SVF-MN0.75S/T2B | 5 | 0.75 | |
SVF-MN1.5S/T2B | 7 | 1.5 | |
SVF-MN2.2S/T2B | 9.6 | 2.2 | |
SVF-MN3.7S/T2B | 17 | 3.7 | |
SVF-MN0.4T4B |
Three phase 380V±15%
| 1.2 | 0.4 |
SVF-MN0.75T4B | 2.5 | 0.75 | |
SVF-MN1.5T4B | 3.7 | 1.5 | |
SVF-MN2.2T4B | 5 | 2.2 | |
SVF-MN3.7T4B | 8.8 | 3.7 | |
SVF-MN5.5T4B | 12.8 | 5.5 | |
SVF-MN7.5T4B | 17 | 7.5 | |
|
Relatedparts
ApplicationFields
SVF-MN series frequencyinverter could be widely used in the industry of food, packing, textile,engraving machines, washing machine, offset machine and rolling door etc.
- Q: Is the laptop power adapter high temperature normal? Is there anything else?
- Summer heat is normal, as long as it is not the kind of hand touch on the bubble temperature, no problem
- Q: 65w adapter and 90w laptop power adapter What is the difference?
- In general, notebooks have to use power consumption is to decide whether to use 65W or 90W adapter power supply, but not to say that 90W must not use the 65W power supply, but his power is not reached, it is possible that the machine is using some of the features Can not start, for example, external equipment, power supply, if the original request is 90W power supply, but you are using the 65W power supply, external equipment can not work properly. But some cases do not need external equipment, so choose a small 65W power supply is very convenient
- Q: Notebook power adapter on how to look at power
- then the same formula can be used to calculate: power (unit: W) = voltage (unit: V) × current (unit: A). For example: the power adapter only identifies the output voltage is 20V, the output current is 4.5A, then we set a formula to know the output power is 20 × 4.5 = 90W.
- Q: What is the motor series parameter setting of the inverter? If it is with the spindle,
- The number of motor poles can be estimated by the parameters: 1000Hz corresponds to 60000rpm, According to "Speed in rpm = 60 * Frequency in Hz / (Number of Poles / 2)", Number of poles = 60 * Frequency indicated by Hz * 2 / Speed in rpm = 60 * 1000 * 2/60000 = 2 poles. The same is true with 333Hz and 20000rpm projections. The number of motor poles for the frequency converter should be entered with the number of poles of the motor that are directly connected to the frequency converter.
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: There is no inverter comes with simple PLC programming function
- The inverter is an AC speed control device, like DC speed control device, DC speed is to change the armature and excitation current, and it is the input AC through the internal circuit into DC, DC and then DC, the last DC AC output, this is the original 50Hz frequency AC can output other frequencies of alternating current, because the speed v is proportional to the frequency f, so you can set the frequency of the inverter to change the speed of the control motor. It does not have its own programming function. But there are servo drives, in fact, is a frequency converter, but can handle some of their own signals, usually from the servo motor on the encoder, and then control the servo motor to achieve precise control.
- Q: The Schneider inverter reports the nlp command
- 1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.
- Q: Fuji inverter motor set the number of poles will not have any effect?
- The number of poles is not the same as the speed is not the same mistake machine can not work or motor coil burned
- Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- and then use the inverter into three-phase AC, 380 volts almost, Can only use the transformer rose to 380 volts.
- Q: Is the laptop power adapter hot?
- Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.