Technical Specification
Control Characteristics | Control Mode | SPWM (Sinusoidal Pulse Width Modulation) control (V/F sensorless vector control) | ||
Freq. Setting Resolution | 0.1Hz | |||
Output Freq. Resolution | 0.1Hz | |||
Torque Characteristics | Including the auto-torque, auto-slip compensation, starting torque can be 150% at 5.0Hz | |||
Overload Endurance | 150% of rated current for 1 minute | |||
Skip Frequency | Three zones, settings range 0.1~400Hz | |||
Acc/Dec Time | 0.1~600s (Independent settings) | |||
V/F Curve | Arbitrary V/F curve setting | |||
Stall Prevention Threshold Frequency Setting | 20~200%, Setting of Rated Current | |||
DC Injection Braking | Operation frequency 0.01~60Hz, output 0~100% rated current, start time 0~5s, stop time 0~25s | |||
Braking Torque | Approx. 20% (up to 125% possible with option brake resistor or brake unit externally mounted) | |||
Operating Characteristics | Frequency Setting | |||
External Signal | Potentiometer 5kΩ/0.5W 0~+10VDC, 4~20mA, interface RS485; Multi-function Inputs (7 steps, Jog, Up/Down) | |||
Operation Setting Signal | Keypad | Set by RUN, STOP | ||
External Signal | S0~S5 can be combined to offer various modes of operation, RS485 serial interface (MODBUS) | |||
Multi-function input signal | Multi-step selection 0 to 7, Acc/Dec inhibit, two Acc/Dec switches, External Counter, Jog, PLC operation, External Base Block, auxiliary motor protection, auxiliary motor control is invalid, drive reset, UP/DOWN key settings | |||
Multi-function output signal | AC drive operating, frequency attained, zero speed, PLC operation, counter attained, over torque, base block, operation mode, fault indication, drive is ready, overheat alarm, emergency stop | |||
Analog output signal | Indicate output frequency, current, voltage, frequency command, speed, power factor output signal | |||
Alarm Output Contact | Drive is fault, the contact will be ON (One form C contact or 3 open collector outputs) | |||
Operation Functions | AVR, over-voltage, over-current stall prevention, 3 fault records, reverse inhibition, momentary power loss restart, DC injection braking, auto torque compensation, slip compensation, S-curve, auto tuning, adjustable carrier frequency, frequency limits, parameters reset, vector control, PID feedback control, external counter, PLC, MODBUS communication, abnormal reset, abnormal restart, digital frequency output, sleep/revival function, 1st/2nd frequency source selections | |||
Protection Functions | Over voltage, over current, under voltage, external fault, overload, contact protection, overheating, electronic thermal, ground fault | |||
Display Keypads | 6-key, 4-digit, 7-segment LED, 4 status LED, master frequency, output frequency, output current, custom units, parameter values for setup, review and faults, RUN, STOP, RESET, FWD/REV | |||
Built-in brake chopper | Built-in for all models | |||
Environment Condition | Protection threshold | IP20 | ||
Pollution Degree | 2 | |||
Installation location | Altitude 1000m or lower, keep from corrosive gasses, liquid and dust | |||
Ambient temperature | -10°C~50°C non-condensing and not frozen (-10°C~40°C for above 5.5KW) | |||
Storage/Transportation temperature | -20°C~60°C | |||
Ambient humidity | Below 90%RH (non-condensing) | |||
Vibration | 9.80665m2(1G) less than 20Hz; 5.88m/s2(0.6G) at 20 to 50Hz | |||
Approvals |
Technical Parameter
VFD Capacity | Input Voltage (V) | Power Capacity (KVA) | Input Current (A) | Output Current (A) | Adapter Motor(KW) |
3.7S/T2B | 3 Phase 230V | 5.9 | 19.6 | 18 | 3.7 |
Model Size
VFD Model | W1 | H1 | W | D | H | Installation Aperture | Weight (Kg) |
SVF-MN3.7S/T2B | 110.0 | 205 | 125 | 166 | 220 | 3.2 |
Accessories
Company Introduction
Shandong Chinsc Electric Technology Co., Ltd. is a manufacturer of professional inverters integrating research and development, production and sales. With advanced technologies, excellent quality, scientific management and perfect services, we are building a first-class inverter manufacturer gradually.
Currently, our company has introduced CHINSC inverter models such as SVF3000 series, SVF-M series, SVF-EV series, SVF-G7 Series 0.4 ~ 630KW, to the markets. With excellent product quality, excellent technology development capabilities and comprehensive after-sales services, CHINSC inverters have won praise among agents and customers across the country.
- Q: 3.7KW inverter with 2.2KW 6-pole motor running to see the inverter shows the current is more than 4A, with the amount of clamp to 2.8A
- Inverter output has high harmonics, the current can not use digital clamp meter amount, and use electric clamp meter. The current of the inverter will vary with the voltage, but not the linear relationship.
- Q: Is it possible to use a different laptop's power adapter?
- It is recommended to use the original comes with the adapter, different adapter output voltage is not the same
- Q: The relationship between the power supply of the notebook and the battery
- The relationship between the laptop power adapter and the battery should not be called a power supply relationship, both of which are devices that power the notebook host. The basic relationship between the power adapter, the battery, and the host is as follows:
- Q: Will the motor suddenly stop when the inverter is suddenly powered down?
- Generally in the absence of external brake or brake case, if the power, the motor is in a free stop state, uncontrolled,will gradually slow down to 0
- Q: Laptop power adapter bad what is the phenomenon?
- Either the power is bad or the machine on the power supply module is bad to repair service
- Q: Fuji inverter motor set the number of poles will not have any effect?
- The number of motor poles set incorrectly, self-learning when the motor parameters are not correct, not the correct parameters of the motor. Inverter control speed is not accurate, and the motor will heat, can not work properly.
- Q: Computer frequency changer to do cd frequency changer how points positive and negative
- Two identical capacitors in series, the capacity is half of the original, the two capacitors in parallel after the same capacity doubled.
- Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- and then use the inverter into three-phase AC, 380 volts almost, Can only use the transformer rose to 380 volts.
- Q: How to learn the inverter debugging and design parameters
- You can find the basic inverter manual, see a few times to try, under normal circumstances, the inverter on the use of manual functions such as research to understand that most of the applications are no problem.
- Q: Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
- If you buy the inverter and the motor can match, it is certainly the quality of the inverter.
Send your message to us
Frequency Inverter mn series 220v 3.7kw high proformance
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 3000 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords