Mini Sensorless Vector Frequency Inverter
Voltage and power range:
3phase, 380v : 0.4~5.5 kw
3/1 phase, 220v: 0.4~3.7kw
Output frequency range: 0.00Hz-400.00 Hz
Application Fields
SVF-MN series frequencyinverter could be widely used in the industry of food, packing, textile,engraving machines, washing machine, offset machine and rolling door etc.
Technical Advantage
Control mode
(1) Open-loop vector control: Steady speed with highprecision, wide range of speed governing, as the speed ratio is 1:150 and frequencyis 0.5Hz, we could output 150% rated torque. Good dynamic performance.
(2) VF control: Multipoint VF curve. This apply to the situation that one frequencyinverter drives multiple motors, such as fan, water pump, engraving machine,injection molding machine etc.
VFD Model | W1 | H1 | W | D | H | Weight (Kg) |
CMAX-MN0.4S/T2B | 74.0 | 141.5 | 85.0 | 113 | 142 | 2.2/1.5 |
CMAX-MN0.75S/T2B | ||||||
CMAX-MN1.5S/T2B |
Relatedparts
Product Features:
1.Adopts 16 bit microprocessor, sine wave PWM control
2.Automatic torque ascension and automatic sliding compensation function
3.Output frequency 0.1-400 Hz
4.8 period of speed setting and 7 period can be running the program
5.Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6.Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7.Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8.The built-in serial communication interface RS-485(baud rate can reach 38400)
9.Save energy running and automatic voltage stabilizing section function (AVR)
1.Adjustable V/F curve Acceleration and automatic and deceleration function
11.Simple vector control and built-in PID control, and the simple positioning function
12,Sleep/wake up function and zero velocity keep function
- Q: Inverter alarm a043, how is it
- When a signal failure occurs, use the DTI board, if necessary, change P215. With P806 (Follow the parameter description) during operation can be converted to no encoder operation A043 is: n-actjump exceeds the allowable change speed of the speed encoder signal (P215) In addition, for the synchronous motor (P095 = 12): The motor speed is 2% higher than the inverter release time point. The inverter in the ready state can not exit. Check processing: Check if the cable is disconnected Check the tachometer to shield the ground Not only on the motor side but also on the inverter side The encoder cable does not allow disconnection Use only recommended encoders The encoder cable is not allowed to be laid with the power cable
- Q: What are the types of power adapter used in notebooks?
- Notebook function is limited, such as power requirements of only 50-70 watts (W). In recent years, power requirements have risen above 100 W, but the expectations for weight and size have not improved accordingly. In addition, the need to meet the low standby power performance in the specification, external power (EPS) efficiency requirements and IEC1000-3-2 harmonic power requirements above 75 W make this challenge more difficult to deal with. This article explores new trends that enable power supply manufacturers to address these challenges and provide alternative solutions to choose from.
- Q: East yuan 7200GS inverter start 11KW 4-pole motor and 2-pole motor need to modify what parameters?
- If you use the environment is relatively poor, it is recommended that you use Austrian St. sealed inverter, this inverter can be moisture, dust, water, oil, corrosion.
- Q: Lenovo laptop power adapter side of the feet which is positive
- Power adapter is a small portable electronic equipment and electrical and electronic power supply conversion equipment, generally by the shell, power transformer and rectifier circuit, according to its output type can be divided into AC output and DC output type; by way of connection Divided into wall and desktop.
- Q: Laptop adapter heat
- In fact, as long as the power adapter temperature is within the design range, that is, the temperature in the normal range, the general is not dangerous! So why is the power supply hot? What kind of temperature range is the normal range? Switching power supply conversion efficiency can only reach 75% -85% or so. The answer is here. Switching power supply conversion efficiency is high enough, it is still difficult to find a better way to convert. Switching power supply in the voltage conversion, a part of the energy loss, in addition to a small part of the loss in the form of waves, the majority of the way out of the heat. Switching power supply power is missing, the loss of energy is also missing, the power of the heat is also large. This is why the desktop power supply to add a fan for cooling reasons. We may wish to count, a 100W switching power supply, in the use of how much energy loss in the above!
- Q: There is no inverter comes with simple PLC programming function
- The inverter is an AC speed control device, like DC speed control device, DC speed is to change the armature and excitation current, and it is the input AC through the internal circuit into DC, DC and then DC, the last DC AC output, this is the original 50Hz frequency AC can output other frequencies of alternating current, because the speed v is proportional to the frequency f, so you can set the frequency of the inverter to change the speed of the control motor. It does not have its own programming function. But there are servo drives, in fact, is a frequency converter, but can handle some of their own signals, usually from the servo motor on the encoder, and then control the servo motor to achieve precise control.
- Q: The notebook power adapter flashes
- 1: Check the socket with a multimeter is normal, the supply voltage is 220V. If the utility voltage is not normal, it is recommended to replace the use of environmental testing. 2: Check with the multimeter whether the output voltage and current of the power adapter match the label. If the gap is very large, and the mains voltage is normal, you can determine the power adapter failure, need to replace the laptop power adapter. 3: If the above check is normal, remove the laptop battery, do not external adapter. Press and hold the notebook power button 5 seconds to repeat 3 times. After releasing the notebook residual charge, insert the power adapter separately, power on the test. 4: If the fault persists, check the notebook's power connector, whether the exception. Such as loose or the appearance of damage and so on. 5: the above checks are normal, basically can be a preliminary judgment is the notebook motherboard failure. Recommended repair service station.
- Q: The Schneider inverter reports the nlp command
- 1, the inverter control circuit with an external 24V power supply, the main circuit did not power 2, PO and PA between the short film can not cause this failure.
- Q: What is the principle and implementation of the inverter?
- How the inverter works: 1. DC can be converted into alternating current through the oscillation circuit 2. The resulting AC power is then boosted by the coil (in this case, the alternating current of the square wave) 3. Rectify the resulting alternating current to obtain a sine wave
- Q: Why G120 inverter to be equipped with 4-pole motor?
- Not necessarily must be equipped with four-pole motor, 2 pole, 6 pole, 8 pole, 12 pole can be used. As long as there is no problem with attention to current matching. Because the amount of 4-pole motor is the largest, all the frequency converter, are based on 4-pole motor for the control model design.
Send your message to us
MINI Series 220v from 0.4kw to 3.7 kw Frequency Inverter
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 50000 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords