• 0.2mm-6.0mm Steel Wire For Armouring Cable System 1
  • 0.2mm-6.0mm Steel Wire For Armouring Cable System 2
  • 0.2mm-6.0mm Steel Wire For Armouring Cable System 3
0.2mm-6.0mm Steel Wire For Armouring Cable

0.2mm-6.0mm Steel Wire For Armouring Cable

Ref Price:
$800.00 / m.t. get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
5mts m.t.
Supply Capability:
3000mt/Month m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Packaging & Delivery of 0.2mm-6.0mm Steel Wire For Armouring Cable

Packaging Detail:

1) By coil: coil weight from 50kg-800kg 2) By plastic reel: each reel is about 25kgs to 40kgs 3) Coils with steel hook and pallets

Delivery Detail:

3 or 4 weeks after the confirmation of the order

 

Specifications of 0.2mm-6.0mm Steel Wire For Armouring Cable

1 used for fencing and armoured cable

2 diameter:0.3mm-6.0mm

3tensile strength:340-550mpa

1 Standard: BS 443, BS 1442(EN10244-2&EN10257-1)

2 Diameters: from 0.2mm-6.0mm

Raw materials of 0.2mm-6.0mm Steel Wire For Armouring Cable

A, wire rod: 1006, 1008,1018, Q195,etc

B, Zinc with 99.995 purity.

4 Diameter tolerance:+/-0.01mm-0.07mm

5 Zinc coating: 35g-275g/m2

 

   Size mm

           Zinc coating min/m2

       A1

   A2

 

   0.80-1.00

 

       150

 

   120

 

   1.00-1.20

 

       180

 

   150

 

   1.20-1.40

 

       200

 

   150

 

   1.40-1.60

 

     220

 

   150

 

   1.60-1.80

 

       220

 

   180

 

   1.80-2.20

 

       240

 

   190

 

   2.20-2.50

 

       260

 

   210

   2.50-3.00

 

       270

 

   240

 

 

6 Torsion Test: 15 turns-45 turns

7 Tensile Strength:

 

         Size mm

 

Tensile strength MPA

 

         0.80-3.50

 

340-550

 

8 Elongations: 10%min

9 Packing:

1) By coil: coil weight from 50kg-800kg

2) By plastic reel: each reel is about 25kgs to 40kgs

3) Coils with steel hook and pallets

10 Usage: Mainly used on armoring cable.

Q: Apple 6splus charge may not support this accessories how to do more
5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
Q: Ipad not charge how the matter. Said the cable or accessories have not been certified, and may not be able to cooperate with this ipad reliable work....
According to the "Power Engineering Cable Design Code" GB-. 5.3.3 only asked for the depth of the cable buried directly: drop the blue skin to the ground depth, not less than 0.7 meters; when located in the roadway or farmland Under the appropriate should be deepened, and should not be less than 1.0 meters. 5.4.3 protected pipe buried in the ground, should meet the requirements under the depth of the pressure and environmental corrosion resistance. Through the uneven settlement of the backfill section and other places to increase the force, it is appropriate to use steel. Another direct burial should be selected armor type.
Q: IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
Ipad charge display does not support the general reasons for this and processing methods: . for non-original charger, it will often appear this situation, which is due to the charger does not meet the specifications caused by the replacement of a qualified charger can be. . if the original charger appears the above failure, please continue to look down. . please check whether the data line is normal. The appearance of the data lines seem normal, which may have been broken. Check the method is to borrow someone else's data line to see if it can charge. . shows the plug symbol is normal is full of display. If full or show the lack of electricity, indicating that the phone tail no problem. . again, check whether the original charger can work properly. You can connect the charger to other USB port to see if the phone is working properly. . if the above two check still can not charge, please try to insert the computer's USB port to see if the computer can identify the phone, to identify if it is to see if the charge, if not identified but not charged, it is estimated that the need for maintenance. If you can not identify can not charge, it is necessary to repair. If you can recognize and charge, replace the data cable and the charger (the original estimate is also damaged). . and then look at the voltage is not too low, not only to the maintenance station to repair, and pay attention to the iPad and iPhone do not mix the power adapter, the voltage is different.
Q: Rt, the charger did not change, has been no problem before, today just plugged into the charger, the results appear as if the problem, before the out of this problem, and now only ipad power off after the power can not be charged, and ipad start , Then immediately prompted the title, can not charge more
At the same time, security monitoring line itself is a weak line
Q: What is the difference between wires and cables?
The introduction of the device is to introduce the cable into the electrical equipment, without changing the explosion-proof type of explosion-proof equipment
Q: Apple 6 Charging Why always show this cable has not yet been certified
And I answered the other person's question is very similar: . the line of the banding distance of not more than 1.2 meters, the two ends of the wire box outlet tube 15CM should be ligation; . casing embedded, then through the basement wall, the surface must be installed rigid Waterproof casing, that is, steel pipe + water ring; through the fire pool, living pool: flexible waterproof casing; (wing ring specific practices can be collected online related Atlas); through the floor, according to whether the design requirements , Under normal circumstances PVC casing on it. Note: . rigid waterproof casing, flexible waterproof casing is a one-time reserved in place, through the floor of the casing of the flower lamb to suppress the barge of Xi Jie Xi Xi shou, is the first stay hole, when the installation of riser Casing, because the floor casing has every layer, the location of the reservation will always be biased, in order to ensure vertical vertical pipe, and finally unified hanging line repair hole and then install the riser and casing. . now most of the bathroom are dirty, waste and diversion, and more of the riser, and so on, the air conditioning casing of all the shear wall should be embedded, to avoid the subsequent damage to the structure of drilling (no stay can only drill) Note that the location of the hole and the installation of the riser will affect the opening of the toilet window. . the casing is the casing, riser is the riser, casing than the riser model 1 to 2 level. . plate at the end of flat, board 2 to 5CM higher to see if you need to do leveling layer.
Q: Wire and cable model ZD what does it mean
The middle of the line is not a problem where there is a problem in the place where the joints check the place of the joints can not do the lines are out to check the time and effort
Q: How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q: What are the T and T, s of the wire and cable test type?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!
Q: What is the warranty period for wire and cable?
Wire and cable warranty period is 30 years of national warranty period. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine. General cable maintenance period is about 15 years, but to ensure that the normal use of the environment, such as the amount of temperature is below 70 degrees, but you are more than 70 working environment to use, of course, may not be used for a year. Therefore, the most important thing is to follow the instructions to use.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches